Laserfiche WebLink
REM POWER CABLE (SUPPLIED LEGEND <br /> 6 5 3 4 WITH REM) JUNCTION BOX 4S UNLESS NOTED OTHERWISE <br /> SEQUENCE OF OPERATIONS (2) <br /> OUTPUT FUNCTIONS O PHOTOELECTRIC SMOKE DETECTOR <br /> SYSTEM ADDITIONAL MANUAL STATION, DOUBLE ACTING <br /> ANNUNCIATION& SYSTEM <br /> TRANSMISSION ACTIONS ® STROBE ALARM <br /> �3/4"C - 2#14THHN,1#14G '� TG-PEM 0 ®� AUDIBLE/VISUAL ALARM <br /> RED <br /> R�` C 0 coB FIRE ALARM PANEL <br /> FACP EVT-FA-45-223 TG-71 S O Z O <br /> (BY FIRE ALARM VENDOR) RN 1 4 7 �_ ® TELEPHONE PANEL <br /> R � /� <br /> JG <br /> =e _ = C� ADT PANEL <br /> ❑ DC STC2 STC1 TRIP BAT AC �O Q FAC FIRE ALARM COMMUNICATOR <br /> 1 2 1 23456 1 23 1 2 �/O V V CONSTRUCTION NOTES <br /> 00 00 11 O=`Q _ 0= [1::::, PROVIDE <br /> CELLULAR <br /> L UFACP.DIALER, AND <br /> DOUNT ADJACENT <br /> EO <br /> THE RED ]��EOL(AS NEEDED) �� •� O <br /> SOLE PATH COMMUNICATION. DIALER SHALL BE <br /> QO Jco� V = COMPATIBLE WITH AT&T CELL SERVICE. <br /> w � PROVIDE (1) CONDUIT PENETRATION FOR PHONE AND <br /> 3/4"C - (1) PHONE CABLE, 4, � y y FIRE ALARM CONNECTIONS. WIRE AS SHOWN. PROVIDE <br /> (1) 2 CONDUCTOR FPL OR = O 2 , , 2 ADDRESSABLE MODULE AS NECESSARY TO PROVIDE <br /> p g Jm���Z Jm��rg Jp�� O O FACP BATTERY CALCULATIONS GENERAL TROUBLE ALARM FROM CELLULAR DIALER TO <br /> APPROVED EQUAL <u p 0 4 0 4 O Q <br /> INPUT CONDITION Q�:co Q��co Q h�y STANDBY ALARM BUILDING FACP. <br /> COMPONENTS QTY. CURRENT CURRENT <br /> STANDBY CONDITION(NORMAL) • i AFC-100(FACE) 1 0.13000A CL22000A PROVIDE (1) CONDUIT PENETRATION FOR 24/12VDC <br /> FIRE ALARM SYSTEM C O�p I p U N CATIONS D ETA E UD-2000(DACT) 0.01600A 0.o23OOA POWER AND EARTH GROUND FROM THE BUILDING FACP <br /> VI IVI C POWER FAILURE • i i i SLC DEVICES suPERwsoRr ALARM POWER SUPPLY. PROVIDE POWER AND EXPANSION <br /> CURRENT CURRENT MODULE AND WIRE AS SHOWN. MAINTAIN <br /> SCALE: NONE E260 E506 N NY CIRCUIT-OPEN,SHORT,GROUND i ! i i PAD-PD 7 0.00630A 0.00030A 0.00210A 0.00210A <br /> w PAD-HD z o.0003oA o.0003oA o.00060A o.0006oA MANUFACTURER'S REQUIRED 1/4" SEPARATION <br /> SEC DEVICE MISSING ! ! ! i <br /> co PAD-DUCT 0 0.00030A 0.00030A o.000OOA o.000OOA BETWEEN POWER AND COMMUNICATION WIRING. <br /> 0 COMM.FAULT/TELGAURD TROUBLE i i ! i PAD100-PSSA/PSDA z o.000zoA a.000zoA 0.00040A o.00040A <br /> BATTERY FAULT-LOW/HIGH VOLTAGE i ! i i ® PROVIDE PHENOLIC LABEL, WHITE LETTERING, RED <br /> PAD100-RM o 0.00024A 0.00o24A o.000OOA O.000OOA BACKGROUND, THAT READS: <br /> PAD100-MIM 1 0.00020A 0.00020A 0.00020A 0.00020A <br /> 00 PAD100-DIM 0 0.00024A 0.00024A O. 0OOA 0.000OOA <br /> �FIRE ALARM PULL STATION • • • • "FIRE ALARM CELLULAR DIALER" <br /> STEP 1: VERIFY SIGNAL STRENGTH AT PROPOSED LOCATION FOR CELLULAR COMMUNICATOR PANEL INDICATED ON w STANDBY ALARM <br /> i • i • <br /> DRAWINGS. IF ACCEPTABLE SIGNAL STRENGTH IS ACQUIRED, SKIP TO STEP 5. �SMOKE DETECTOR CURRENT CURRENT <br /> ¢ NAG CKT 1(AUX PWa) 0.018A 0.11000A 0.01800A 0.11000A PROVIDE CELL ANTENNA AND EVALUATE FIELD SIGNAL <br /> STEP 2: IF ORIGINALLY PROPOSED LOCATION IS INADEQUATE, FIELD TEST *SIGNAL STRENGTH WITHIN A 20FT RADIUS HEAT DETECTOR ! i i i PAC CRT 2 0ODA 05400A 000OOOA O.5400A STRENGTH IN ACCORDANCE WITH DETAIL 2. INSTALL <br /> Ir <br /> TO IDENTIFY LOCATION(S) SUITABLE FOR INSTALLATION OF REMOTE/EXTERNAL CELLULAR ANTENNA. LL - 700A OtOOOOA OtOOOOA 700000A CONDUIT AND EXTENDED ANTENNA CABLE AS <br /> COORDINATE THE FINAL ANTENNA LOCATION WITH BOEING AND SPACE USERS (IF IMPACTED) FOR SLC ALARM LED O.00A 0.03600A O.Do000A 0.03600A NECESSARY TO REMOTE MOUNT ANTENNA IF COVERAGE <br /> TOTAL 0.16730A 0.8963A IS NOT SUITABLE AT FACP LOCATION. UPDATE ROM <br /> APPROVAL PRIOR TO ROUGH-IN AND SKIP TO STEP 4. R' TOTAL STANDBY CURRENT DRAW= 0.1673 AMPS WITH SELECTED CABLE LENGTH AND PROVIDE REDLINES <br /> STEP 3: IF ACCEPTABLE *SIGNAL STRENGTH IS NOT ACHIEVED WITHIN 20FT OF ORIGINAL PROPOSED LOCATION FOR jSR x STANDBY TIME 48 HOURS TO BOEING ENGINEER. <br /> CELLULAR COMMUNICATOR PANEL, PROPOSE ALTERNATE LOCATION FOR CELLULAR PANEL. COORDINATE �O�O STANDBY AMP HOUR TOTAL= 8.0304 AH <br /> WITH BOEING AND SPACE USERS FOR POTENTIAL LOCATIONS, PREFERABLY NEAR ORIGINAL LOCATION. TOTAL ALARM CURRENT DRAW= 0.8963 AMPS © FOR REMOTE INSTALLATIONS PROVIDE PHENOLIC LABEL, <br /> O� WHITE LETTERING, RED BACKGROUND, THAT READS: <br /> STEP 4: LOCATE AND PROVIDE EXTERNAL CELLULAR ANTENNA, EXTERIOR MOUNTING BRACKET AND COAXIAL CABLE H �OP� �5��. x ALARM THE 0.167 HOURS <br /> FROM CELLULAR COMMUNICATOR TO THE ANTENNA. THE ANTENNA AND PANEL SHOULD BE LOCATED �O ALARM AMP HOUR TOTAL= o.1so AH "FIRE ALARM CELLULAR ANTENNA" <br /> L1:06 �O STANDBY AH+ ALARM AH = 8.18 AH <br /> WITHIN 20FT OF EACH OTHER' `�' X DE-RATING FACTOR 1.20(207) <br /> ATOR <br /> STEP 5: PROVIDE 24VDC POWER, MONITORING CIRCUIT, AND TELEPHONE LINE TO CELLULAR COMMUNICATOR FROM O��\O� �Op O� TOTAL AN REQUIREo= s.8z AH SETINSTINGS EAND CELL OUARE PHONE POST CNO NUMBER.BUILDING FACP. O ya_ H L1:05 OFF\00 MINIMUM <br /> BATTERY <br /> SIZE PROVIDED: 12 AH PRINTED LABEL, HANDWRITTEN INFORMATION IS NOT <br /> STEP 6: PROVIDE REQUIRED SET-UP, PROGRAMMING AND TESTING OF CELLULAR COMMUNICATOR EQUIPMENT PER F O NOTE: 0.167 EQUALS 10 MINUTES OF ALARM TIME ACCEPTABLE. PROVIDE SETTINGS AND CELLULAR <br /> THE MANUFACTURER'S INSTRUCTIONS. CELLULAR DIALER SHALL BE CONFIGURED AND INSTALLED AS A 5-4 ��0� cry INFORMATION TO BOEING ENGINEER. <br /> SOLE PATH FOR FIRE COMMUNICATIONS. s O F L1:04 O� <br /> L1:07*' <br /> *ACCEPTABLE SIGNAL STRENGTH SHALL BE DETERMINED BY MANUFACTURERS SPECIFICATIONS AND LOCAL AHJ ��O FF\O �. �P� O� FACP VOLTAGE DROP CALCULATION <br /> ORDINANCES. s O �� S O <br /> L1:08�' L1:03 <br /> h� QJ� �N ACMET VOLTAGE CURRENT WIRE TYPE 1pppS FEET RESISTANCE LAST DEVICE <br /> DROP <br /> CELLULAR COMMUNICATOR INSTALLATION SEQUENCE MONITORED BY TYCO AND <br /> ��O pC' �. �P SIGNAL SENT TO CENTRAL NAc1(Aux) 24 voc o.no A glanwc soup 3.07 0 o.osla 23ss voc o.03% <br /> F L1:02 <br /> SCALE: NONE E260 E506 S O �ti Q BOEING FIRE DEPARTMENT NAc2 24 VDC 0.540 A g14Awc soup 3.m 105 0.6447 23.65 VDC 1.45% <br /> L1'�� ��ti BFPO N/A 24 voc 0.000 A g14AWG SOLID 3.07 0 0 00.00 voc O% <br /> s � DOG. S S0- N/A 24 VDC 0.000 A #14AWG SOLID 3.07 0 00.00 VDC 0% <br /> 45-302 BUILDING SYSTEM FACP POINTS u:01 <br /> L1:11 OFF' �00� <br /> POINT NUMBER/ZONE BOEING DESCRIPTION FACP POINT - COMMENTS - GRID/SHEET LOC. O�� OP& <br /> L1:01 1 SMK @ FACP FACP SMOKE DETECTOR - A.5-3 1E260 S MIM CELLULAR <br /> / L1:10 1:12 ANALOG PHON LINE DIALER <br /> L1:02 2 MAN PULL E DR AST DOOR PULL STATION - A.5-3/1E260 (PRIMARY5 TG-7FS-A BILL OF MATERIALS <br /> L1:03 3 SMK OFFICE SW OFFICE SMOKE DETECTOR S.W. - A-2/1E260 ITEM QTY. PART NO. MANUFACTURER DESCRIPTION <br /> 15CD 15CD 110CD 45-302 FACP <br /> L1:04 4 MAN PULL W DR WEST DOOR PULL STATION - A-3/1E260 1 1 3992753 POTTER FIRE ALARM CONTROL PANEL <br /> L1:05 5 HAT WOMEN RESTROOM WEMON'S R.R. HEAT DETECTOR - A-3/1E260 =NAC2 2 1 3992769 POTTER UD-2000 DACT CARD <br /> L1:06 6 HAT MEN RESTROOM MEN'S R.R. HEAT DETECTOR - A.5-3/1E260 3 9 3992732 POTTER PAD100 6" BASE <br /> L1:07 7 SMK OFFICE W WEST OFFICE SMOKE DETECTOR - A-l/lE260 ANA OG PHONE LINE <br /> L1:08 8 SMK OFFICE NW NORTHWEST OFFICE SMOKE DETECTOR - A-1/1E260 75CD 75CD (SECONDARY) 4 7 3992770 POTTER PAD200 PHOTO DETECTOR <br /> / <br /> L1:09 9 SMK OFFICE NE NORTHEAST OFFICE SMOKE DETECTOR - A.5-1/1E260 EVT-FA-45-302 *TWO SEPARATE PATHWAYS FOR SIGNAL REQUIRED BY CODE,AS SHOWN. 5 2 3992735 POTTER PAD100 HEAT DETECTOR <br /> P:10 10 45-272 SMK S IIBLDG. 272 S. SMOKE DETECTOR - A-3/1E261 6 2 3992720 POTTER PAD100 PULL STATION <br /> 1_1:11 11 45-272 SMK N BLDG. 272 N. SMOKE DETECTOR - A-2/1E261 7 1 3992700 POTTER PAD100 MICO INPUT MODULE <br /> 1 L1:12 12 ICELL DIALER FAIL CELL DIALER TROUBLE - A.5-3/1E260 PNL. B/10 8 2 SLA1104 POWERPATROL 12VDC 12 AH BATTERIES <br /> 9 2 BK-P2RL SYSTEM SENSOR HORN/STROBES <br /> BUILDING FACP POINTS LIST BUILDING FIRE ALARM SYSTEM FIRE ALARM SYSTEM RISERS 10 2 BK-SRL SYSTEM SENSOR STROBES <br /> SCALE: NONE E506 SCALE: NONE E506 11 1 BK-P2RK SYSTEM SENSOR WEATHER PROOF HORN/STROBES <br /> 12 1 TG-7FS-A TELGUARD ATT CELLULAR DIALER <br /> 13 1 SSU00689 SPACEAGE FIRE ALARM STORAGE CABINET <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWNA SUBTITLE CURRENT REVISION SYMBOL DATE <br /> ACCEPTABILITY CHECKED 03.05.24 FIRE ALARM SYSTEM DETAILS 33311362 A 03.06.24 <br /> THIS DESIGN AND/OR CHECKED � <br /> NEW FIRE MONITORING PANEL REPLACEMENT W9063564 ABR MDK 05.18.23 Michael Regan,ET SPECIFICATION IS APPROVED M.REGAN 03.06.24 SHEET <br /> BOE/NG ENGINEER E E506 \ <br /> A SHOP DRAWINGS 33311362 AGOW/JS AGOW/KM 03.06.24 ® n APPROVED BY DEPT. GATE K.MULLEN 02.22.24 <br /> M('.E'fiRVElI1fIFh'`Y/UeTill CHECKED <br /> echnician ID:144327 APPROVED BUILDING 45-302 JOB No. COMP NO. <br /> xpi-03101/2026 33311362 <br /> APPROVED EVERETT, WA DWG No. 45-302-E506 <br />