Laserfiche WebLink
ADD. BASE EQUIPMENT LEGEND / BILL OF MATERIAL <br /> PROJ. PROD. <br /> SYMBOL QTY QTY ITEM DESCRIPTION PART NUMBER MANUFACTURER <br /> FACP 0 1 1 FIRE ALARM CONTROL PANEL FC901 SIEMENS <br /> rELc 0 1 2 TELGUARD CELLULAR COMMUNICATOR TG-7FS-LTE-A SIEMENS <br /> ❑ SIEMENS <br /> BOENG COMMERCAL NRPLANE GROUP H 0 2 5 ADDRESSABLE HEAT DETECTOTR R OH 92 21 SIEMENS <br /> 1D SIEMENS <br /> EVERETT ERE PANE REP A C E M E N T q WP 0 1 6 W PROOF WALL MOUNTED HORN STROBE ASWP-24/75-FR SIEMENS <br /> I-®4 0 2 7 WALLALL MOUNTED HORN STROBE SL2HSWR-F SIEMENS <br /> ® 0 2 8 WALL MOUNTED STROBE SL2SWR-F SIEMENS <br /> IFD M 0 1 9 MINI INPUT MONITORING MODULE XTRI-M SIEMENS <br /> BUILDING 4 5 - 2 0 6 /3 01 IFD R 0 - 10 ADDRESSABLE RELAY MODULE XTRI-R SIEMENS <br /> BOEING EVERETT FACILITY <br /> 3003 WEST CASINO ROAD <br /> EVERETT, WASHINGTON 98203 <br /> FIRE ALARM GENERAL ELECTRICAL NOTES SEQUENCE OF OPERATION — ABBREVIATED: <br /> 1. THE INSTALLATION OF THE SYSTEM(S) SHALL MEET THE REQUIREMENTS OF THE <br /> SPECIFICATION, NFPA 70 (NEC), NFPA 72, ALL APPLICABLE LOCAL CODES, AND ACTUATION OF ANY MANUAL ALARM STATION, SPOT TYPE SMOKE DETECTOR SHALL: <br /> THE EQUIPMENT MANUFACTURER'S RECOMMENDATIONS. <br /> 1. ILLUMINATE THE "ALARM" INDICATING LAMP ON THE DEVICE IN ALARM. <br /> 2. FASTEN EQUIPMENT TO STRUCTURAL MEMBERS OF BUILDING OR METAL SUPPORTS 2. LIGHT THE "RED" ALARM LAMP ON THE FACP (FIRE ALARM CONTROL PANEL). <br /> ATTACHED TO STRUCTURE, OR TO CONCRETE SURFACES. 3. ANNUNCIATE THE APPROPRIATE "FIRE ALARM" MESSAGE ON THE FACP LCD <br /> 3. ALL PANELS SHALL BE MOUNTED WITH SUFFICIENT CLEARANCE FOR OBSERVATION, DISPLAY. <br /> TESTING AND MAINTENANCE. ALL JUNCTION BOXES & COVERS SHALL BE PAINTED 4. SOUND THE FACP INTERNAL AUDIBLE DEVICE. <br /> RED. 5. ACTIVATE ALL AUDIBLE AND VISUAL ALARM NOTIFICATION DEVICES. <br /> 6. TRANSMIT A "FIRE ALARM" SIGNAL TO THE MONITORING STATION. <br /> 4. ALL WIRE SHALL BE SUPPLIED AND INSTALLED IN COMPLIANCE WITH THE <br /> REQUIREMENTS OF NFPA 70, ARTICLE 760 AND AS NOTED ON THE DRAWINGS. TROUBLE CONDITIONS CAUSED BY DETECTION SYSTEM FAULT, DETECTION SYSTEM <br /> FAULT, NOTIFICATION APPLIANCE POWER SUPPLY FAILURE OR TRANSFER TO BATTERY <br /> 5. A CONSISTENT COLOR CODE FOR FIRE ALARM SYSTEM CONDUCTORS SHALL BE POWER SHALL: <br /> USED THROUGHOUT THE INSTALLATION. <br /> 6. WIRE RUNS ARE SHOWN DIAGRAMMATICALLY. EXACT LOCATION SHALL BE 1. ANNUNCIATE THE APPROPRIATE "TROUBLE" MESSAGE ON THE FACP LCD DISPLAY. <br /> DETERMINED IN THE FIELD BUT SHALL GENERALLY CONFORM TO TO THE LAYOUT 2. LIGHT THE "TROUBLE" LAMP ON THE FACP. <br /> SHOWN. INSTALLER SHALL MAINTAIN A SET OF DRAWINGS WHICH SHOW ALL 3. TRANSMIT A 'TROUBLE" SIGNAL TO THE MONITORING STATION. <br /> CHANGES IN ROUTING OF CONDUIT AND/OR CABLING. A COMPLETE SET OF THESE <br /> "MARKED UP" DRAWINGS SHALL BE PROVIDED TO SEATRONICS UPON COMPLETION <br /> OF THE INSTALLATION. <br /> 7. ALL NAG DEVICES SHALL BE INSTALLED IN THE SEQUENCE SHOWN ON THE <br /> DRAWINGS. <br /> 8. ALL FIELD WIRING SHALL BE TESTED FOR SHORTS, OPENS AND GROUNDS PRIOR <br /> TO CONNECTION TO THE CONTROL PANEL AND BEFORE DETECTORS ARE PLUGGED <br /> INTO THE BASES. <br /> 9. SHIELD DRAIN WIRE: UNLESS OTHERWISE NOTED, CABLE SHIELD DRAIN WIRE SHALL <br /> BE GROUNDED ONLY AT THE THE PANEL/MODULE OF CIRCUIT ORIGIN. AT ALL <br /> OTHER LOCATIONS DRAIN WIRE SHALL BE SPLICED THROUGH AND INSULATED FROM <br /> CONTACT WITH ANY POTENTIAL GROUND SOURCE. <br /> Permit#: FA2404-006 <br /> SCOPE OF WORK: site Address: 3003 W Casino Rd <br /> 45-206 Applicant: Seatronics Inc <br /> ——— — ——— — ——— — ——— — ——— — THE SCOPE OF WORK FOR THE BOEING 45-202 IS TO REPLACE THE EXISTING FIRE Application Date:04/23/2024 <br /> ALARM CONTROL PANEL WITH A NEW SIEMENS FC901, INSTALL A NEW CELLULAR Description: BLDG 45-206 Fire Alarm Replacement <br /> 15cd 15cd 75cd 75cd 75cd DIALER, AND REPLACE THE EXISTING DISCONTINUED SMOKE DETECTORS. Review Date: 04/25/2024 <br /> WID <br /> EOL I tw <br /> POINT NUMBER NOMENCLATURE BV`TT <br /> 1/5 1/4 1/3 1/2 1/1 Everett Fire Dept.Permit Review <br /> I #14/2 I 1 . Q1 . it Status:Approved <br /> 45-301 I 11:09 L1:08 11:07 11:06 11:05 L1:04 L1:03 11:02 L1:01 TELG I Reviewed By:KBrown <br /> H F F S F S S S MONITORING INPUT NUMBER: 04/2 5/2 0224 1 1:56:58 <br /> 11 - INPUT 1 AM <br /> #16/2 FD M i 12 - INPUT 2 <br /> L1:10 13 - INPUT 3 <br /> A,C,D 14 - INPUT 4 <br /> L2:12 L2:11 <br /> S S I FACP I ADDRESSABLE DEVICE NUMBER <br /> SIGNALING LINE CIRCUIT NUMBER <br /> I I I <br /> I -- - --- - --- - --- - --- - - - - - -J NICETyC.Eastman-25W <br /> L NICETC a' <br /> �J � -Level IV <br /> R I S r R D GRAM Et=rtlTcation Ex iiessq March 01,2025 <br /> SCALE:tN.T.S. PERMIT SUBMITTAL <br /> 03.02.24 PO BOX 1138 <br /> AUBURN,WA 98071 <br /> SEATRONICS 253-939-6060 <br /> TIRE PROTECTION SERVICES Job No. —N0. <br /> 9132326 9132326-E1 <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE <br /> ACCEPTABILITY SEATRON 03.02.24 SUBTITLE FIRE DETECTION&ALARM SYSTEM CURRENT REVI51°" SYMBOL _ DATE <br /> - FIRE ALARM PANEL REPLACEMENT SEA 03.02.24 THIS DESIGN AND/OR CHECKED 9132326 3.02.24 <br /> SPECIFICATION IS APPROVED BILL OF MATERIAL&NOTES EET 1 <br /> BOE/A/G® ENGINEER TITLE <br /> APPROVED BY DEPT. DATE BOEING EVERETT CREW SHELTER E 1 <br /> CHECKED <br /> APPROVED BUILDING 45-206 JOB NO. 9132326 COMP NO. <br /> APPROVED ELECTRICAL MASTER - TUKWILA, WA DWG No. 45-206-E1 <br />