My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-214 2024-12-05
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-214
>
3003 W CASINO RD BLDG 45-214 2024-12-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/5/2024 8:43:41 AM
Creation date
11/6/2024 8:33:38 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-214
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
74
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Fire Terminal (and equipment) C-WEB Network Module <br /> The Fire Terminal (Model FT924) consists of the Fire <br /> Terminal Board (Model FT12001-U1); the Operating Unit <br /> (Model FCM2018-U3 or Model FCM2019-U3), and a one- <br /> height-unit(1 HU)system enclosure. <br /> Each Model FT924 terminal contains one(1) backlit, <br /> 2"—x—4-314"Video Graphics Array (VGA) monochrome LCD <br /> .��. <br /> screen with LEDs for displaying system status. An audible ' }` <br /> will sound when there are 'unacknowledged' events on the <br /> system. <br /> The display of each operating unit categorizes events by <br /> type, providing a separate event tab for Alarm, Gas Alarm, <br /> Supervisory, and Trouble events. The quantity of active The C-WEB network module (Model FN2001-U1) is used to <br /> events of each type is listed in each event tab. The display network up to 16 FACPs and the Fire Terminal (Model <br /> provides two(2)full lines of text message for each event. FT924), via the C-net system bus. The C-WEB network <br /> Each event can have a 40-character custom message module is plugged into the Operating Unit (Model <br /> describing the location for a given event. In addition to the FCM2018-U3 or Model FCM2019-U3). <br /> text message, the system displays the category of the active Model FN2001-U1 supports 'peer-to-peer' networking <br /> event: (e.g. — Automatic Alarm, Water Flow, Manual, etc) — between the following systems: <br /> the category means more to responding officials than Model FC922 <br /> model numbers. Model FC924 <br /> The Fire Terminal Boards contain the site-specific program Model FT924 <br /> configuration which is created in'Cerberus Works'. The Model FN2001-U1 connects to system-bus inputs and <br /> outputs, and the module has ground-fault monitoring, as <br /> NOTE:Canadian installations require an 8-event display.The well as an integrated degrade-mode function. <br /> Canadian version of the panel firmware enables the 8-event <br /> display mode. Redundant networking is accomplished with one (1) <br /> network module [simple loop trouble] per panel. There is <br /> Digital Alarm Communicator Transmitter electrical isolation between the system bus and the FACP. <br /> ' Power Supply Modules <br /> • <br /> • <br /> • <br /> The Digital Alarm Communicator Transmitter(DACT) is used <br /> to provide communication between the Cerberus PRO fire- <br /> alarm control panels (Models FC922 and FC924); one (1) <br /> fire terminal (Model FT924) and an off-premises remote <br /> monitoring station. <br /> Each DACT(Model FCA2015-U1) can also support additional <br /> 3rd -party Internet Protocol (IP) and Global System Mobile <br /> (GSM) communication technologies, which include: The 170-Watt power supply (Model FP2011-U1) and 300- <br /> Telguard and Sur-Gard. Thus, Model FCA2015-U1 is UL Watt power supply (Model FP2012-U1) provide primary, <br /> Listed as compatible with 3rd-party communicators: Bosch regulated (24VDC, nominal) power for normal operation to <br /> B465, Starlink LTE dual channel versions,Telguard, and DSC. Siemens — Fire Safety systems. Both power supplies are <br /> Model FCA2015-U1 connects to the periphery boards,and it filtered and regulated. Model FP2011-U1 is rated 6.5 Amps <br /> enables remote transmission of alarms and events via a at 24VDC, nominal. Model FP2012-U1 is rated 11.5 Amps at <br /> public telephone line. Additionally, each DACT module 24VDC, nominal. <br /> supports two (2) lines and four (4) accounts, and can <br /> transmit serial information (including the address of the <br /> event)to the monitoring station. <br /> Model FCA2015-U1 can be programmed to perform <br /> automatic daily testing as often as required. <br /> Siemens <br /> Smart Infrastructure—Building Products —3— usa.siemens.comlfire <br />
The URL can be used to link to this page
Your browser does not support the video tag.