Laserfiche WebLink
Specifications <br />Main Board — (continued) <br />There are also LEDs to indicate when audible circuits are <br />'active' or 'silenced.' The main board supports four (4) <br />system -control buttons, including: Acknowledge; Alarm <br />Silence; Unsilence, and Reset. <br />The system offers an off -normal warning feature, <br />alerting users when active devices are not ready for <br />reset. These active devices may include manual stations <br />that have not been reset; smoke detectors with smoke <br />remaining in the optical chamber, etc. <br />Additionally, the main board supports an <br />alphanumeric keypad, as well as navigation keys, <br />which are used for scrolling maintenance functions <br />and system configuration. <br />The main board supports connection for up to 50 <br />addressable devices, via one (1) 'Class A', or two (2) <br />'Class B' circuits. The loop supports all C-NET devices, <br />including the Cerberus PRO intelligent and Model 'H'- <br />series devices. The main board also supports one (1) <br />'Class A' or two (2)'Class B' NACs. <br />Each NAC supports a maximum 2.5 Amps — with 2.5 <br />Amps, max, allowed between the NACs. Each NAC can <br />be set to a synchronized strobe, for horn -strobe <br />devices, or for audible devices. Audible devices can be <br />set for: <br />• 'STEADY' <br />• 'ANSI Temporal 3'I'ANSITemporal 4' <br />• 'March Time 30 160 1120 Codes' <br />The main board supports four (4)'Form C'relays for <br />Alarm, Trouble, Supervisory and User Programmable <br />events. Each relay is rated at 2 Amps at 30VDC <br />maximum, resistive. The main board supports two (2) <br />auxiliary 24VDC connections. Upon system reset, one <br />(1) connection interrupts the power for five seconds <br />for use with (4) four -wire conventional detectors. Each <br />auxiliary -power output is 24VDC, nominal — rated at <br />0.75 Amps. <br />The main board contains a built-in DACT that provides <br />communication between Model FC901 and with the <br />central or remote monitoring station. The built-in DACT <br />supports two (2) separate programmable accounts, as <br />well as two (2) connections to the public -switched <br />telephone network. The connections support RJ31 X <br />male connectors. <br />(For compatibility with each Model FC901 FACP, see <br />the Central Station Receiver Compatibility Table on <br />the last page of this data -sheet document.) <br />The main board contains a battery -charging circuit, <br />providing connection to lead -acid batteries rated at <br />24VDC, nominal. The main board can charge up to <br />18 AH batteries. <br />The main board contains a universal serial bus (USB) <br />connector that supports connection for system <br />configuration and module firmware upload, via the <br />custom -configuration tool. <br />Model FC901 can be configured using the custom - <br />configuration tool or manually from the alphanumeric <br />keypad on the main board. An auto -configuration <br />feature creates a basic system configuration of all <br />connected devices to accelerate initial system <br />commissioning. <br />50-Point Addressable System Enclosure <br />The Model FH901-U3 I R3 enclosure for the 50-point <br />addressable fire system, Model FC901, supports all <br />system modules. The enclosure also supports up to <br />12AH batteries. <br />Note: For systems requiring larger than 12AH <br />batteries, use a OUL Listed battery box. <br />The Model FH901-U3 I R3 enclosure for the 50-point <br />panel is comprised of a dual -mounting setup that <br />allows the main board to be partially mounted in a <br />lower -to -upper position. When temporarily installed <br />in the lower position, technicians are allowed more <br />space to install field wiring at the time of system set- <br />up. When field -wiring installation is complete, the <br />main board shall be moved to the upper position for <br />standard mounting prior to applying power to the <br />system. <br />Additionally, the enclosure supports an optional <br />battery bracket (Model FHA901-U1) that can be used <br />to secure batteries up to 12AH. Model FHA901-U1 is <br />required to comply with seismic certification, <br />pursuant to ASC I SEI 7-05, Section 13.2.2. <br />A flush -mount trim kit (Model FHA902-Ul I R1) is <br />also available for use when flush mounting <br />Model FH901-U3 I R3. <br />50-Point Power Supply <br />The Model FCM901-U3 main board also supports <br />connection to the system power supply. The 6.5A <br />(170-Watt) power supply (Model FP2016-U1) <br />incorporates a 4.OA, non-resettable slow -blow fuse <br />on the primary input, and includes a built-in AC -line <br />filter for surge and noise suppression. <br />Model FP2016-U1 mounts in a standard Siemens — <br />Fire Safety enclosure, and there are no serviceable <br />Siemens — Fire Safety parts to be maintained. <br />SIEMENS Industry, Inc. <br />Building Technologies Division <br />Cerberus° PRO <br />