My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-312 2024-12-06
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-312
>
3003 W CASINO RD BLDG 45-312 2024-12-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2024 8:15:24 AM
Creation date
11/6/2024 9:48:14 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-312
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Horn -Strobes I Output Current Draw <br />Ir Current Ratings (Amps @ 2410 HIGH dB <br />Model <br />Setting <br />15cd <br />30cd <br />75cd <br />110cd <br />150cd <br />177cd <br />SL2HSC' <br />Series " <br />CONT <br />0.037 <br />14�10 <br />.109 <br />0.146 <br />0.208 <br />T3 <br />T31r4 <br />Current Ratings (Amps @ 2410 LOW dB <br />Model <br />Setting <br />15cd <br />30cd <br />75cd <br />110cd <br />150cd <br />177cd <br />SL2HSC' <br />Series:" <br />CONT <br />0.030 <br />� <br />0.039 <br />.070 <br />F <br />0.102 <br />0.139 <br />0.201 <br />T3 <br />T3rr4 I <br />Horn -Only I Output Current Draw <br />Current Ratings (Amps) <br />RMS Current @ 24VDC <br />Model <br />Regulated <br />Volta a Range <br />High <br />Low <br />'SL2iesHC' <br />Ser <br />12VDC (8-17.5V) <br />0.025 <br />0.020 <br />24VDC (16-33V) <br />0.028 <br />0.021 <br />Strobe -Only I Output Current Draw <br />Current Ratings (Amps) <br />Regulated Voltage Range <br />Model 16.0 - 33.0 VDC 16.0 - 33.0 VRMS <br />SL2SC' <br />Series" 15cd 30cd 75cd 110cd 150cd 177cd <br />0.022 0.030 0.060 1 0.086 1 0.125 0.185 <br />Horn I Output Ratings (UL) <br />UL Sound Output Ratings (dBA) <br />Reverberant per UL464 @ 10 feet <br />SL2HC <br />SL2HC & SL2HSC <br />Model <br />Setting <br />@ 12VDC <br />@ 24VDC <br />SL2HC' <br />and— <br />CONT I T31 <br />High dBA <br />High dBA <br />SL2HSC' <br />Series <br />IT3/T4 <br />g0 <br />80 <br />CONT I T31 <br />]F_78 <br />Low dBA <br />Low dBA <br />78 <br />T31T4 <br />Horn I Output Ratings (ULC) <br />ULC Sound Output Ratings (dBA) <br />Anechoic per ULCS525-16 @ 3.05 meters <br />SL2HC <br />SL2HC & SL2HSC <br />Model <br />Setting <br />@ 12VDC <br />@ 24VDC <br />SL2HV— <br />and — <br />CONT 1 T31 <br />High dBA <br />High dBA <br />SL2HSC' <br />Series" <br />I T31T4 <br />85 <br />91 <br />CONT I T31 <br />IF <br />Low dBA <br />Low dBA <br />79 <br />86 <br />I T31T4 <br />" RMS current ratings are per UL maximum RMS method. <br />UL max current rating is the maximum RMS current within the listed <br />voltage range (16 - 33 V for 24V <br />A For audible appliances, the max current is usually at the maximum <br />listed voltage (16 -33V for 24V units) <br />"For unfiltered FWR ratings, see installation instructions <br />GENERAL NOTES: <br />1. Strobes are designed to flash at 1-flash-per-second minimum over their" Regulated Voltage Range." <br />2. NFPA-72 specifies a flash rate of 1-to-2 flashes -per -second. <br />3. All Candela ratings represent minimum effective Strobe intensity based on UL 1971. <br />Genera I Properties <br />MODEL 'SL2'-series <br />OPERATING - 32°F (0°C) to 122-F (50°C) <br />TEMPERATURE: - for indoor use only <br />RELATIVE HUMIDIT <br />F 93%, maximum <br />- 12 VDC I VFWR 4 8.0 - 17.5 V <br />OPERATING <br />' 24 VDC I VFWR 4 16.0 - 33.0 V <br />VOLTAGE RANGES: <br />(12 VDC for Model SL2HC only) <br />- UL 1638, 1971 1 ULC-S526-16 <br />STROBE <br />Field -selectable 15cd 130cd 175cd 110cd <br />OUTPUT RATING: <br />150cd 1 177cd Candela outputs <br />STROBE FLASH RATE: <br />Strobes are designed to flash at one -flash -per -second <br />• all Siemens Addressable Panels <br />Siemens PAD -series NAC extenders <br />STROBE <br />SYNCRONIZATION: <br />Siemens Dual -Sync (DSC) modules, <br />which provide the unique Siemens <br />proprietary synchronization protocol <br />• Continuous <br />• Code 3 (112 second on, 1/2 second off; then <br />112 second on, 1/2 second off; followed <br />TEMPORAL <br />by 112 second on, 1-1/2 second off and repeat) <br />PATTERN: <br />NOTES: The Code 3 pattern is specified by ANSI <br />and NFPA72 for Standard Emergency <br />Evacuation Signaling. <br />Physical Properties <br />w MODEL'SL2'-series <br />- White -or -red textured, ultraviolet (UV) stabilized, <br />MATERIAL: colored impregnated engineered plastic <br />- Exceeds 94V-0 UL flammability rating <br />WEIGHT: <br />0.55 Lbs. (0.24 Kg.) <br />LENS TYPE: <br />LED strobe situated in a rugged Lexan lens <br />Horns: <br />6.27"(15.9 cm.) x 6.27"(15.9 cm.) x 1.32" (3.35 cm.) <br />DIMENSIONS: <br />Horn -Strobes: <br />6.27"(15.9 cm.) x 6.27"(15.9 cm.) x 1.69" (4.29 cm.) <br />Mounting and Wiring Properties <br />MODEL -SL2'-series <br />INDOOR Ceiling -mount applications <br />MOUNTING: Model SLSPBBC to any Single -Gang Backbox or <br />to 4" (10.2 cm.) Square Box <br />WIRING TYPE: "l2 —#18, American Wire Gauge (AWG) <br />Siemens <br />Smart Infrastructure — Building Products -3- usa.siemens.comlfire <br />
The URL can be used to link to this page
Your browser does not support the video tag.