My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-715 2024-12-05
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-715
>
3003 W CASINO RD BLDG 45-715 2024-12-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/5/2024 9:58:52 AM
Creation date
11/6/2024 11:43:05 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-715
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i I <br /> I REMOTE LAMP <br /> IF SHIELEDED CABLE IS USED, __ ___ (OPTIONAL) <br /> CONNECT DRAINS <br /> TOGETHER& 1 o I i b MODEL RL-Hr MODEL I <br /> INSULATE FROM GROUND. <br /> I - <br /> RD SLC CKT.IN 5 6 SLC CKT.OUT <br /> SIEMENS REMOTE+ 11 TO REMOTE TEST SW. IF SHIELEDED CABLE IS USED, SIEMENS <br /> DUCT SMOKE DETECTOR _- WHT A + - A <br /> REMOTE CNTL 12 CONNECT DRAINS TOGETHER& <br /> O MODEL FDBZ492-HR __ B�K (WHERE APPLICABLE) <br /> REMOTE- 13 INSULATE FROM GROUND. XTRI-D <br /> ALM. RLY. A <br /> SLC SLC CKT.IN <br /> 7 <br /> TBl I CKT I RELAY CONTACTS Qo Qo <br /> 1 2 3 4 5 6 7 8 9 10 RATED 120 vac, SLC CKT.OUT ® 1+ SLC <br /> zavoc,zs AMPS DB-1 1 SMOKE/HEAT DETECTOR MOUNTING BASE A ® OTATus LED <br /> 2_ COMS <br /> I I I CONNECT TO SHUTDOWN CONTROL CIRCUIT TYPICAL WIRING DIAGRAM EOLR 3 <br /> FOR AHU VFD OR TO CMCS SYSTEM ® GROUND SHIELD <br /> + I 470 OHM INPUT 1 DRAIN AT MODULE <br /> SLC CKT. IN I MONITORING. SEE PLANS FOR CONNECTION NTS D 4 N/A 8 ® ONLY <br /> INSTRUCTION AT EACH UNIT. ® _ <br /> II MONITORED SWITCH OR ® EOLR <br /> GROUND SHIELD D <br /> A I I CONTACT , ® 5 GND INPUT 2 7 470 OHM <br /> I I +—SLC CKT. OUT MODULE <br /> DRAIN AT MO 6 <br /> I I I A ONLY MONITORED SWITCH OR <br /> I I L--ITUBIREMOTE LAMP (WHERE APPLICABLE) CONTACT <br /> --- MODEL RL-HC, RL-HW <br /> L------ <br /> HIGH BAY HORN/STROBES <br /> ONLY — MOUNT AT 20' <br /> AFF. <br /> MAIN FIRE ALARM PANELS HORN/STROBES MOUNT TO XTRI—D DUAL INPUT ADDRESSABLE MONITOR MODULE <br /> AIR DUCT SMOKE DETECTOR HOUSING IN FIRE CONTROL ROOM 4"SQR BOX, DOUBLE GANG TYPICAL WIRING DIAGRAM <br /> OR SINGLE GANG BOX OR NTS <br /> TYPICAL WIRING DIAGRAM FACP FACP—MAIN MUD RING. <br /> NTS <br /> EXPANSION 244" <br /> o o TO TOP <br /> (HIGH BAY ONLY) <br /> ENCLOSURE FACP ENCLOSURE: 96 IF SHIELEDED CABLE IS USED, SIEMENS <br /> 27"H x 26"W x 8'D 27"H x 26"W x 8'b CONNECT DRAINS TOGETHER& <br /> 70" TO TOP INSULATE FROM GROUND. XTRI—R <br /> A <br /> MANUAL STATIONS SLC CKT.IN <br /> MOUNT TO DEEP p <br /> BATT BATT ° OR SINGLE <br /> MUD RING.BOX SLC CKT.OUT ® 1+ SLC <br /> ® 2— COMS OsrATus LED <br /> BATTERY ENCLOSURE: 48" EOUR <br /> ® 3 <br /> 12"H x 26"W x 9"D TO TOP 470 OHM D ® INPUT 1 <br /> a r8 <br /> MONITORED SWITCH OR fo _ RELAY <br /> CONTACT / ® 5 GND CONTACTS ? ® OUTPUT TO DEVICE BEING <br /> GROUND SHIELD J _ 4A,120VAC CONTROLLED(DOOR <br /> DRAIN AT MODULE 4A,30VDC 6 ® RELEASE,FAN SHUTDOWN, <br /> ONLY ETC.)SELECT NC OR NO <br /> FLOOR CONTACTS AS REQUIRED. <br /> SELECT WIRE GUAGE AS <br /> REQUIRED. <br /> FIRE ALARM EQUIPMENT MOUNTING ELEVATIONS <br /> (NO SCALE) TYPICAL WIRINGTDIAGRAM�Y ADDRESSABLE MONITOR MODULE <br /> NTS <br /> IF SHIELEDED CABLE IS USED, <br /> CONNECT DRAINS TOGETHER& <br /> INSUUTE FROM GROUND. <br /> OQUAD O A IF SHIELEDED CABLE IS USED, SIEMENS <br /> INPUT OUTPUT SLC CKT.IN CONNECT DINDC""' <br /> / 1 SLC CKT.OUT INSULATEXTRI-S <br /> MODULE <br /> SIEMENS MODEL NA 1 q SLC CKT.IN <br /> FDCI0422 -IN 6 SLC CKT.OUT <br /> OUTPUT TO DEVICE BEING A RLY1 -OUT 6 1+ SLC STATUS LED <br /> CONTROLLED(DOOR RELEASE, A OUT A SLC +IN 5 - COMS O <br /> FAN SHUTDOWN,ETC.)SELECT +OUT 5 <br /> WIRE GUAGE AS REQUIRED. B OUT2B MONITORED SWITCH OR EOLR3(TYP.) CONTACT 470 OHM4 INPUT 1N/A 8 <br /> OUTPUTS:5 AMPS MAX EA.,30VDC 1 EDER 470 INPUT 1 MONITORED SWITCH OR(NOT FOR 120VAC USE) 1 D OHM TYP. 5 GND N/A 7 <br /> ID <br /> RLY3 CONTACT _ <br /> INPUT 2 D DRAIN AT MODULE N/A 6 <br /> OUT C ONLY <br /> RLY4 INPUT 3 3OUT D 3 D <br /> 4 <br /> INPUT a 4 / D <br /> L GROUND SHIELD <br /> DRNNS AT MODULE <br /> O O ONLY. XTRI—S SINGLE INPUT ADDRESSABLE MONITOR MODULE <br /> TYPICAL WIRING DIAGRAM <br /> NTS <br /> FDC10422 4 INPUT/ 4 RELAY ADDRESSABLE MONITOR MODULE <br /> TYPICAL WIRING DIAGRAM <br /> NTS q� <br /> Timothy C.Eastman-253- "C <br /> NICET C� �°� _l <br /> � r LeveIIV <br /> l Ication Expires:March 01,2025 <br /> PERMIT SUBMITTAL <br /> 03.25.24 PD BOX 1138 <br /> AUBURN,WA 98071 <br /> SE ATRONICS 253-939-6060 <br /> FIRE PROTECTION SERMCES, NO. owG Noof . <br /> 9132326 9132326-E508 <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> - FIRE ALARM PANEL REPLACEMENT SEA 03.25.24 THIS DESIGN AND/OR CHECKED FIRE ALARM SYSTEM DETAILS 9132326 03.25.24 <br /> SPECIFICATION IS APPROVED SHEET-ABOE//VG® APPROVED BY DEPT DATE N IN E BQEING EVERETT E508 7 <br /> CHECKED <br /> APPROVED BUILDING 45-715 JOB NO� 9132326 COMP ND. <br /> APPROVED ELECTRICAL MASTER I.1l. EVERETT, WA DWG NO, 45-715—E508 <br />
The URL can be used to link to this page
Your browser does not support the video tag.