Laserfiche WebLink
Application Data <br /> Installation of Model HI921 intelligent, addressable thermal detector requires a two-wire SLC circuit. In many retrofit <br /> cases, existing wiring may be used. 'T-tapping' is permitted only for Style 4 (Class B) wiring. Model HI921 is polarity <br /> insensitive when not used in Class-X mode, which can reduce installation and debugging times. The unit's value is <br /> multiplied with built-in ISOtechnology the True Class-X- NFPA 72 compliant SLC isolation feature supporting up to 252 <br /> isolation ready devices per loop. When used in mixed mode a maximum of 30 non-isolated devices between isolation <br /> devices (wired in polarity-insensitive mode). Each detector fits into one (1) wall-or-ceiling footprint, and only occupies <br /> one (1)address on the signal-line circuit(SLC). <br /> Model HI921 can be applied within the maximum 50-feet (15.24 m.) center spacing (2,500 sq. ft. [232.3 sq. mJ) per <br /> Underwriters' Laboratories. This application guide is based on ideal conditions, specifically, smooth-ceiling surfaces, <br /> minimal air movement, and no physical obstructions between potential fire sources and the actual detector. Do not <br /> mount detectors in close proximity to heating I ventilation I air-conditioning (HVAC) outlets. Exposed joists or beamed <br /> ceilings may also affect safe spacing limitations for detectors. <br /> Should questions arise regarding detector placement, observe NFPA 72 guidelines. Good fire-protection system <br /> engineering and common sense dictate how and when fire detectors are installed and used. Contact your local <br /> Siemens - Fire Safety distributor or sales office whenever you need assistance applying Model HI921 in unusual <br /> applications. <br /> Be sure to follow NFPA guidelines and UL Listed I ULC Listed installation instructions-included with every Siemens-Fire <br /> Safety detector-and local codes for all fire-protection equipment. <br /> Specifications <br /> Model HI921 is a plug-in, (2) two-wire thermal (heat) detector, compatible with Cerberus PRO Modular I FireFinder <br /> XLSIV and Model FC9-series FACPs. Each Model HI921 detector has microcomputer-chip technology and highly stable, <br /> solid-state electronic circuitry. Model HI921 detectors utilize a modern, accurate and shock-resistant thermistor to <br /> sense temperature changes. This electronic-sensing method virtually eliminates thermal lag associated with mechanical <br /> temperature-sensing devices and provides almost instantaneous temperature status to the FACP. <br /> Model HI921 provides seven (7)field-selectable, pre-programmed temperature settings: <br /> Fixed Temperature set points(5) Rate of Rise set points(2) <br /> • Fixed 135°F(57°C) • Rate-of-Rise: 15°F I min. (8.3°C)at fixed 135°F(57°C) <br /> • Fixed 145°F(63°C)• Fixed 155°F(68°C) • Rate-of-Rise: 15°F I min. (8.3°C)at fixed 175°F(79°C)——— <br /> • Fixed 165°F(74°C) <br /> • Fixed 175°F(79°C) <br /> Additionally,the Model HI921 detector has the following optional feature: <br /> • Model HI921 provides indication of potential water freezing for sprinkler systems, via configuration for reporting a <br /> low-temperature warning of 407(4.4°C). <br /> This feature is compatible with Cerberus PRO Modular systems, as well as with FireFinder XLSIV and Cerberus PRO <br /> FCIFV922 or FCIFV924 FACPs. <br /> Mounting Diagrams <br /> �o----------4.13" (10.5 <br /> --------------- ------- ------- <br /> I D <br /> t4.4 CM.I <br /> i <br /> i <br /> i <br /> I i <br /> Siemens <br /> usa.siemens.comlfire <br /> Smart Infrastructure - Building Products -3- <br />