My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-715 2024-12-05
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-715
>
3003 W CASINO RD BLDG 45-715 2024-12-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/5/2024 9:58:52 AM
Creation date
11/6/2024 11:43:05 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-715
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ADD. BASE EQUIPMENT LEGEND / BILL OF MATERIAL <br /> PROJ. PROD. <br /> SYMBOL CITY QTY ITEM DESCRIPTION PART NUMBER MANUFACTURER <br /> FRCP - 1 1 FIRE ALARM CONTROL PANEL FC901 SIEMENS <br /> TELc - 1 2 TELGUARD CELLULAR COMMUNICATOR TG-7FS-LTE-A SIEMENS <br /> BOENG COMMERDAL NRPLANE GROUP SIEMENS <br /> — 1 5 ADDRESSABLE HEAOT OP921 SIEMENS <br /> D DEDTECEOTR R H 921 SIEMENS <br /> EVERETT IRE PANE REP A C E M E N T WP - 2 6 W PROOF WALL MOUNTED HORN STROBE ASWP-24/75-FR SIEMENS <br /> 2 7 WALLALL MOUNTED HORN STROBE SL2HSWR-F SIEMENS <br /> ® 8 WALL MOUNTED STROBE SL2SWR-F SIEMENS <br /> F1 F51 M - 1 9 MINI INPUT MONITORING MODULE XTRI-M SIEMENS <br /> BUILDING 4 5 - 715 /0 0 5 OR - - 10 ADDRESSABLE RELAY MODULE XTRI-R SIEMENS <br /> BOEING EVERETT FACILITY <br /> 3003 WEST CASINO ROAD <br /> EVERETT, WASHINCTON 98203 <br /> FIRE ALARM GENERAL ELECTRICAL NOTES SEQUENCE OF OPERATION — ABBREVIATED: <br /> 1. THE INSTALLATION OF THE SYSTEM(S) SHALL MEET THE REQUIREMENTS OF THE <br /> SPECIFICATION, NFPA 70 (NEC), NFPA 72, ALL APPLICABLE LOCAL CODES, AND ACTUATION OF ANY MANUAL ALARM STATION, SPOT TYPE SMOKE DETECTOR SHALL: <br /> THE EQUIPMENT MANUFACTURER'S RECOMMENDATIONS. <br /> 1. ILLUMINATE THE "ALARM" INDICATING LAMP ON THE DEVICE IN ALARM. <br /> 2. FASTEN EQUIPMENT TO STRUCTURAL MEMBERS OF BUILDING OR METAL SUPPORTS 2. LIGHT THE "RED" ALARM LAMP ON THE FACP (FIRE ALARM CONTROL PANEL). <br /> ATTACHED TO STRUCTURE, OR TO CONCRETE SURFACES. 3. ANNUNCIATE THE APPROPRIATE "FIRE ALARM" MESSAGE ON THE FACP LCD <br /> 3. ALL PANELS SHALL BE MOUNTED WITH SUFFICIENT CLEARANCE FOR OBSERVATION, DISPLAY. <br /> TESTING AND MAINTENANCE. ALL JUNCTION BOXES & COVERS SHALL BE PAINTED 4. SOUND THE FACP INTERNAL AUDIBLE DEVICE. <br /> RED. 5. ACTIVATE ALL AUDIBLE AND VISUAL ALARM NOTIFICATION DEVICES. <br /> 6. TRANSMIT A "FIRE ALARM" SIGNAL TO THE MONITORING STATION. <br /> 4. ALL WIRE SHALL BE SUPPLIED AND INSTALLED IN COMPLIANCE WITH THE <br /> REQUIREMENTS OF NFPA 70, ARTICLE 760 AND AS NOTED ON THE DRAWINGS. TROUBLE CONDITIONS CAUSED BY DETECTION SYSTEM FAULT, DETECTION SYSTEM <br /> FAULT, NOTIFICATION APPLIANCE POWER SUPPLY FAILURE OR TRANSFER TO BATTERY <br /> 5. A CONSISTENT COLOR CODE FOR FIRE ALARM SYSTEM CONDUCTORS SHALL BE POWER SHALL: <br /> USED THROUGHOUT THE INSTALLATION. <br /> 6. WIRE RUNS ARE SHOWN DIAGRAMMATICALLY. EXACT LOCATION SHALL BE 1. ANNUNCIATE THE APPROPRIATE 'TROUBLE" MESSAGE ON THE FACP LCD DISPLAY. <br /> DETERMINED IN THE FIELD BUT SHALL GENERALLY CONFORM TO TO THE LAYOUT 2. LIGHT THE "TROUBLE" LAMP ON THE FACP. <br /> SHOWN. INSTALLER SHALL MAINTAIN A SET OF DRAWINGS WHICH SHOW ALL 3. TRANSMIT A "TROUBLE" SIGNAL TO THE MONITORING STATION. <br /> CHANGES IN ROUTING OF CONDUIT AND/OR CABLING. A COMPLETE SET OF THESE <br /> "MARKED UP" DRAWINGS SHALL BE PROVIDED TO SEATRONICS UPON COMPLETION <br /> OF THE INSTALLATION. <br /> 7. ALL NAC DEVICES SHALL BE INSTALLED IN THE SEQUENCE SHOWN ON THE <br /> DRAWINGS. <br /> 8. ALL FIELD WIRING SHALL BE TESTED FOR SHORTS, OPENS AND GROUNDS PRIOR <br /> TO CONNECTION TO THE CONTROL PANEL AND BEFORE DETECTORS ARE PLUGGED <br /> INTO THE BASES. <br /> 9. SHIELD DRAIN WIRE: UNLESS OTHERWISE NOTED, CABLE SHIELD DRAIN WIRE SHALL <br /> BE GROUNDED ONLY AT THE THE PANEL/MODULE OF CIRCUIT ORIGIN. AT ALL <br /> OTHER LOCATIONS DRAIN WIRE SHALL BE SPLICED THROUGH AND INSULATED FROM <br /> CONTACT WITH ANY POTENTIAL GROUND SOURCE. <br /> Permit#: FA2404-014 <br /> SCOPE OF WORK: Site Address: 3003 W casino Rd <br /> ApplicanC Sealronics Inc <br /> 75cd 75cd THE SCOPE OF WORK FOR THE BOEING 45-202 IS TO REPLACE THE EXISTING FIRE ApplicationDate:04/23/2024 <br /> IF ALARM CONTROL PANEL WITH A NEW SIEMENS FC901, INSTALL A NEW CELLULAR Description: BLDG 45-715 Fire Alarm Replacement <br /> DIALER, AND REPLACE THE EXISTING DISCONTINUED SMOKE DETECTORS. Review Date: 04/25/2024 <br /> EOL1/2 1/1 POINT NUMBER NOMENCLATURE <br /> #14/2 1 01 11 <br /> 11:05 L1:04 L1:03 L1:02 L1:01 TELG I EVERETT <br /> r.rBETT <br /> MONITORING INPUT NUMBER: Everett Fire Dept.Permit Review <br /> 45-005 I F F S S FD I 1 — INPUT 1 Status:Approved <br /> r —— — ——— — — -1 M 12 — INPUT 2 Reviewed By:KBrown <br /> #16/2 L1:06 I 3 - INPUT 3 04/25/2024 12:29:43 <br /> 75cd 75cd 14 - INPUT 4 PM <br /> EOL WP WID I FACP i ADDRESSABLE DEVICE NUMBER <br /> 2/2 2/1 I I I SIGNALING LINE CIRCUIT NUMBER <br /> L2:08 L2:07 <br /> II Timothy G.Eastman-253- "C <br /> L-- - --- - -J — — — — NICETC nret�_l <br /> ��r�S-Level IV <br /> RISER DIAGRAM �tlTcason Ex orewprML o,,202e <br /> SCALE: N.T.S. PERMIT SUBMITTAL <br /> 03.25.24 PD BOX 1138 <br /> AUBURN,WA 98071 <br /> SEATRONICS 253-939-6060 <br /> FIRE PROTECTION SERVICES JOB NO.of 1 BwG xB. <br /> 9132326 9132326-E1 <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY DRAWN DATE SUBTITLE FIRE DETECTION&ALARM SYSTEM CURRENT REVISION SYMBOL DATE <br /> — FIRE ALARM PANEL REPLACEMENT SEA 03.25.24 THIS DESIGN AND/OR CHECKED 9132326 03.25.24 <br /> s ECIFICATION IS APPRovED BILL OF MATERIAL&NOTES SHEET 1 <br /> BOE/NG® APPROVED BY I DEFT DATE N IN TITLE BOEING EVERETT CREW SHELTER E 1 1 <br /> CHECKED <br /> APPROVED BUILDING 45-715 JOB NO� 9132326 DDMP NO� <br /> APPROVED ELECTRICAL MASTER EVERETT, WA Dwc NO. 45-715-E1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.