Laserfiche WebLink
Technical Data <br /> Horn-Strobes I Output Current Draw Horn I Output Ratings(LIL) <br /> Current Ratings(Amps @ 2419 HIGH dB UL Sound Output Ratings(dBA) <br /> Reverberant per UL464 @ 10 feet <br /> Model Setting 15cd 30cd 75cd 110cd 135cd 185cd Model Setting SL2HW SL2HW&SL2HSW <br /> SL2HS' CONT SL2HW'- @ 12VDC @ 24VDC <br /> Series" T3 0.037 0.046 0.077 0.109 0.146 0.208 and- CONT I T31 High dBA High dBA <br /> T31r4 SL2HSW' <br /> Current Ratings(Amps @ 2410 LOW dB <br /> Series:" I T3/T4 g0 80 <br /> m15cd CONT[T31 Low dBA Low dBA <br /> Model Setting 30cd 75cd 110cd 135cd 185cd T3/T4 78 78 <br /> 5L2HS' CONT <br /> Series:" T3 0.030 0.039 0.070 0.102 0.139 0.201 Horn I Output Ratings(ULC) <br /> T31r4 <br /> ULC Sound Output Ratings(dBA) <br /> Horn-Only I Output Current Draw Anechoic per ULCS525-16 @ 3.05 meters <br /> Current Ratings(Amps) Model Setting SL2HW SL2HW&SL2HSW <br /> @ 12VDC @ 24VDC <br /> RMS Current @ 24VDC SL2HW'- <br /> Regulated Hi h Low and- CONT[T31 High dBA High dBA <br /> Model Voltage Range 9 SL2HSW' I T31T4 g5 91 <br /> SL2H' 12VDC(8-17.5V) 0.025 0.020 Series: <br /> Series" CONT I T31 Low dBA Low dBA <br /> 24VDC(16-33V) 0.028 0.021 <br /> I T31T4 79 86 <br /> Strobe-Only Output Current Draw <br /> Current Ratings(Amps) "RMS current ratings are per UL maximum RMS method. <br /> UL max current rating is the maximum RMS current within the listed <br /> Regulated Voltage Range voltage range(16-33V for 24V <br /> Model A For audible appliances,the max current is usually at the maximum <br /> Model 16.0-33.0 VDC 16.0-33.0 VRMS listed voltage(16.33Vfor24Vunits) <br /> Series:" 15cd 30cd 75cd 110cd 135cd 185cd "For unfiltered FWR ratings,see installation instructions <br /> 0.022 0.030 0.060 1 0.086 0.125 0.185 <br /> GENERAL NOTES: <br /> 1.Strobes are designed to flash at 1-flash-per-second minimum over their"Regulated Voltage Range." <br /> 2.NFPA-72 specifies a flash rate of 1-to-2 flashes-per-second. <br /> 3.All Candela ratings represent minimum effective Strobe intensity based on UL 1971. <br /> Technical Data <br /> General Properties Physical Properties <br /> MODEL'SL2'-series MODEL-SL2'-serie <br /> OPERATING - 32'F(0°C)to 122'F(50'C) -White-or-red textured,ultraviolet(UV)stabilized, <br /> TEMPERATURE: - for indoor use only <br /> MATERIAL: colored impregnated engineered plastic <br /> RELATIVE HUMIDITY: 11 93°/u,maximum -Exceeds 94V-0 UL flammability rating <br /> OPERATING - 12 VDC/VFWR 4 8.0-17.5 V WEIGHT: 0.35 Lbs.(0.16 Kg.) <br /> VOLTAGE RANGES: - 24 VDC/VFWR 4 16.0-33.0 V LENS TYPE: LED strobe situated in a rugged Lexan lens <br /> (12 VDC for Model SL2HW only) <br /> STROBE - UL 1638,1971 1 ULC-S526-16 Actual Appliance: I Single-Gana Trim Plate: <br /> OUTPUT RATING: Field-selectable 15cd 30cd 75cd 110cd DIMENSIONS: 4.79"(12.1 cm.)[H] 5.25"(13.3 cm.)[H] <br /> 135cd 1185cd Candela outputs 2.76"(7.0 cm.) [W] 4.58"(11.6 cm.)[W] <br /> STROBE FLASH RATE: Strobes are designed to flash at one-flash-per-second 1.18"(2.9 cm.)[D] 0.32"(0.81 cm.)[D] <br /> - all Siemens Addressable Panels <br /> STROBE - Siemens PAD-series NAC extenders Mounting and Wiring Properties <br /> SYNCRONIZATION: ' Siemens Dual-Sync(DSC)modules, <br /> which provide the unique Siemens MODEL'SL2 series <br /> proprietary synchronization protocol <br /> ■ <br /> - Continuous - Wall-mount applications <br /> - Code 3(1/2 second on,1/2 second off; then INDOOR - Model SL2SBB to any Single-Gang Backbox or to <br /> 1/2 second on,1/2 second off;followed MOUNTING: 4"(10.2 cm.)square box with trim plate and <br /> TEMPORAL by 1/2 second on, 1-1/2 second off and repeat) separately ordered mud-ring <br /> PATTERN: <br /> NOTES: The Code 3 pattern is specified by ANSI <br /> and NFPA72 for Standard Emergency WIRING TYPE: "12-018,American Wire Gauge(AWG) <br /> Evacuation Signaling. <br /> Siemens <br /> Smart Infrastructure —Building Products -3- usa.siemens.comlfire <br />