Laserfiche WebLink
Technical Data <br /> Horn-Strobes I Output Current Draw Horn I Output Ratings(LIL) <br /> Current Ratings(Amps @ 2410 HIGH dB UL Sound Output Ratings(dBA) <br /> �� Reverberant per UL464 @ 10 feet <br /> Setting 15cd 30cd 75cd 110cd 150cd 177cd SL2HC SL2HC&SL2HSC <br /> SL2 HSC' SL2HC' <br /> Model CONT Model Setting @ 12VDC @ 24VDC <br /> Series" T3 0.037 0.146 0.208 and- CONT I T31 High dBA High dBA <br /> T31r4 0.046 0.077 0.109 SL2HSC' <br /> Current Ratings(Amps @ 24V)LOW d8 � <br /> Series" I T3/T4 g0 80 <br /> CONT 1 T31 Low dBA Low dBA <br /> Model Setting15cd 30cd 75cd 110cd 150cd 177cd T3/T4 78 78 <br /> SL2HSC' CONT <br /> IF <br /> Series:" T3 0.030 0.039 0.070 0.102 0.139 0.201 Horn I Output Ratings(ULC) <br /> T3rr4 I � ULC Sound Output Ratings(dBA) <br /> Horn-Only I Output Current Draw Anechoic per ULCS525-16 @ 3.05 meters <br /> Current Ratings(Amps) SL2HC SL214C&SL2HSC <br /> RMS Current @ 24VDC Model Setting @ 12VDC @ 24VDC <br /> Regulated SL2HC'- <br /> Volta ( a High Low and CONT 1 T31 High dBA High dBA <br /> Model SL2HSC' 1 T31T4 g5 91 <br /> 'SL2HiesC' 12VDC(8-17.5V) 0.025 0.020 Series" <br /> Ser <br /> 24VDC(16-33V) 0.028 0.021 CONT I T31 Low dBA Low dBA <br /> I T31T4 IF 79 86 <br /> Strobe-Only I Output Current Draw <br /> Current Ratings(Amps) "RMS current ratings are per UL maximum RMS method. <br /> UL max current rating is the maximum RMS current within the listed <br /> Regulated Voltage Range voltage range(16-33 V for 24V <br /> Model 16.0-33.0 VDC 16.0-33.0 VRMS "For audible appliances,the max current is usually at the maximum <br /> SL2SC' listed voltage(16-33V for 24V units) <br /> Series:" 15cd 30cd 75cd 110cd 150cd 177cd "For unfiltered FWR ratings,see installation instructions <br /> 0.022 0.030 0.060 0.086 0.125 0.185 <br /> GENERAL NOTES: <br /> 1.Strobes are designed to flash at 1-flash-per-second minimum over their"Regulated Voltage Range." <br /> 2.NFPA-72 specifies a flash rate of 1-to-2 flashes-per-second. <br /> 3.All Candela ratings represent minimum effective Strobe intensity based on UL 1971. <br /> Technical Data <br /> General Properties Physical Properties <br /> MODEL'SL2'-series w MODEL'SL2'-series <br /> OPERATING - 32°F(0°C)to 122-F(50°C) <br /> TEMPERATURE: - for indoor use only -White-or-red textured,ultraviolet(UV)stabilized, <br /> RELATIVE HUMIDITY: 93%,maximum MATERIAL: colored impregnated engineered plastic <br /> Exceeds 94V-0 UL flammability rating <br /> OPERATING - 12 VDC I VFWR 4 8.0-17.5 V WEIGHT: 0.55 Lbs.(0.24 Kg.) <br /> VOLTAGE RANGES: ' 24 VDC I VFWR 4 16.0—33.0 V <br /> (12 VDC for Model SL2HC only) LENS TYPE: LED strobe situated in a rugged Lexan lens <br /> STROBE - UL 1638,1971 1 ULC-S526-16 Horns: <br /> OUTPUT RATING: Field-selectable 15cd 130cd 175cd 110cd 6.27"(15.9 cm.)x 6.27"(15.9 cm.)x 1.32"(3.35 cm.) <br /> 150cd 1 177cd Candela outputs DIMENSIONS: Horn-Strobes: <br /> STROBE FLASH RATE: Strobes are designed to flash at one-flash-per-second 6.27"(15.9 cm.)x 6.27"(15.9 cm.)x 1.69"(4.29 cm.) <br /> • all Siemens Addressable Panels <br /> STROBE Siemens PAD-series NAC extenders Mounting and Wiring Properties <br /> SYNCRONIZATION: Siemens Dual-Sync(DSC)modules, <br /> which provide the unique Siemens MODEL-SL2'-series <br /> proprietary synchronization protocol <br /> • Continuous <br /> INDOOR Ceiling-mount applications <br /> • Code 3(1/2 second on,1/2 second off; then MOUNTING: Model SLSPBBC to any Single-Gang Backbox or <br /> 1/2 second on,1/2 second off;followed to 4"(10.2 cm.)Square Box <br /> TEMPPATTORA RNL by1/2second on, 1-1/2second off and repeat) WIRING TYPE: "12—#18,AmericanWireGauge(AWG) <br /> NOTES: The Code 3 pattern is specified by ANSI <br /> and NFPA72 for Standard Emergency <br /> Evacuation Signaling. <br /> Siemens <br /> Smart Infrastructure — Building Products —3— usa.siemens.com/fire <br />