Laserfiche WebLink
PEM POWER CABLE (SUPPLIED LEGEND <br /> 6 5 3 4 WITH PEM) <br /> GENERAL NOTES <br /> REFERENCE DRAWINGS <br /> 3�3/4"C — 2#14THHN,1#14G 2 0 <br /> TG-PEM NEN <br /> BIN <br /> FACP EVF—FA-45-715 TG—7 FS <br /> (BY FIRE ALARM VENDOR) CONSTRUCTION NOTES <br /> R PROVIDE CELLULAR DIALER, AND MOUNT ADJACENT TO <br /> 3 THE BUILDING FACP. CONFIGURE DIALER TO PROVIDE <br /> ❑O T SOLE PATH COMMUNICATION. DIALER SHALL BE <br /> COMPATIBLE WITH AT&T CELL SERVICE. <br /> DC STC2 STC1 TRIP BATT AC <br /> 1 2 1 2 3 4 5 6 Fl-2-31 PROVIDE (1) CONDUIT PENETRATION FOR PHONE AND <br /> BB B� BBB BB FIRE ALARM CONNECTIONS. WIRE AS SHOWN. PROVIDE <br /> ADDRESSABLE MODULE AS NECESSARY TO PROVIDE <br /> GENERAL TROUBLE ALARM FROM CELLULAR DIALER TO <br /> TE.1( NEEDM) BUILDING FACP. <br /> PROVIDE (1) CONDUIT PENETRATION FOR 24/12VDC <br /> POWER AND EARTH GROUND FROM THE BUILDING FACP <br /> (1) PHONE CABLE, POWER SUPPLY. PROVIDE POWER AND EXPANSION <br /> (1) 2 CONDUCTOR FPL CABLE, <br /> MODULE AND WIRE AS SHOWN. MAINTAIN <br /> MANUFACTURER'S REQUIRED 1/4" SEPARATION <br /> APPROVED EQUAL-< BETWEEN POWER AND COMMUNICATION WIRING. <br /> ® PROVIDE PHENOLIC LABEL, WHITE LETTERING, RED <br /> BACKGROUND, THAT READS: <br /> FIRE ALARM SYSTEM COMMUNICATIONS DETAIL "FIRE ALARM CELLULAR DIALER° <br /> SCALE: NONE E260 E506 PROVIDE CELL ANTENNA AND EVALUATE FIELD SIGNAL <br /> STRENGTH IN ACCORDANCE WITH DETAIL 2. INSTALL <br /> CONDUIT AND EXTENDED ANTENNA CABLE AS <br /> NECESSARY TO REMOTE MOUNT ANTENNA IF COVERAGE <br /> IS NOT SUITABLE AT FACP LOCATION. UPDATE BOM <br /> WITH SELECTED CABLE LENGTH AND PROVIDE REDLINES <br /> TO BOEING ENGINEER. <br /> © FOR REMOTE INSTALLATIONS PROVIDE PHENOLIC LABEL, <br /> WHITE LETTERING, RED BACKGROUND, THAT READS: <br /> STEP 1: VERIFY SIGNAL STRENGTH AT PROPOSED LOCATION FOR CELLULAR COMMUNICATOR PANEL INDICATED ON <br /> DRAWINGS. IF ACCEPTABLE *SIGNAL STRENGTH IS ACQUIRED, SKIP TO STEP 5. "FIRE ALARM CELLULAR ANTENNA" <br /> STEP 2: IF ORIGINALLY PROPOSED LOCATION IS INADEQUATE, FIELD TEST *SIGNAL STRENGTH WITHIN A 20FT RADIUS INSIDE CELL ENCLOSURE POST COMMUNICATOR <br /> TO IDENTIFY LOCATION(S) SUITABLE FOR INSTALLATION OF REMOTE/EXTERNAL CELLULAR ANTENNA. SETTINGS AND CELLUAR PHONE NUMBER. PROVIDE <br /> COORDINATE THE FINAL ANTENNA LOCATION WITH BOEING AND SPACE USERS (IF IMPACTED) FOR PRINTED LABEL, HANDWRITTEN INFORMATION IS NOT <br /> APPROVAL PRIOR TO ROUGH—IN AND SKIP TO STEP 4. ACCEPTABLE. PROVIDE SETTINGS AND CELLULAR <br /> INFORMATION TO BOEING ENGINEER. <br /> STEP 3: IF ACCEPTABLE *SIGNAL STRENGTH IS NOT ACHIEVED WITHIN 20FT OF ORIGINAL PROPOSED LOCATION FOR <br /> CELLULAR COMMUNICATOR PANEL, PROPOSE ALTERNATE LOCATION FOR CELLULAR PANEL. COORDINATE <br /> WITH BOEING AND SPACE USERS FOR POTENTIAL LOCATIONS, PREFERABLY NEAR ORIGINAL LOCATION. <br /> STEP 4: LOCATE AND PROVIDE EXTERNAL CELLULAR ANTENNA, EXTERIOR MOUNTING BRACKET AND COAXIAL CABLE <br /> FROM CELLULAR COMMUNICATOR TO THE ANTENNA. THE ANTENNA AND PANEL SHOULD BE LOCATED <br /> WITHIN 20FT OF EACH OTHER. <br /> STEP 5: PROVIDE 24VDC POWER, MONITORING CIRCUIT, AND TELEPHONE LINE TO CELLULAR COMMUNICATOR FROM <br /> BUILDING FACP. <br /> STEP 6: PROVIDE REQUIRED SET—UP, PROGRAMMING AND TESTING OF CELLULAR COMMUNICATOR EQUIPMENT PER <br /> THE MANUFACTURER'S INSTRUCTIONS. CELLULAR DIALER SHALL BE CONFIGURED AND INSTALLED AS A <br /> SOLE PATH FOR FIRE COMMUNICATIONS. <br /> *ACCEPTABLE SIGNAL STRENGTH SHALL BE DETERMINED BY MANUFACTURERS SPECIFICATIONS AND LOCAL AHJ <br /> ORDINANCES. <br /> CELLULAR COMMUNICATOR INSTALLATION SEQUENCE <br /> SCALE: NONE E260 E506 <br /> Timothy C.Eastman-253- <br /> NICET CI�NI 1 <br /> r IV <br /> Vrti Icalion Exrewq March 01,zoz5 BILL OF MATERIALS <br /> PERMIT SUBMITTAL ITEM QTY. PART NO. MANUFACTURER DESCRIPTION <br /> 1 1 TG-7FS TELGUARD CELLULAR DIALER FOR FIRE SYSTEMS <br /> 03.25.24 2 1 TG-PEM TELGUARD POWER AND EXPANSION MODULE <br /> 3 1 EXDL-0 TELGUARD EXTERNAL OMNI-DIRECTIONAL ANTENNA <br /> 4 1 ACD-XX TELGUARD ANTENNA CABLE AND MOUNTING BRACKET 12,35,50,OR 100 <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY DRAWN DATE SUBTITLE CURRENT REVISION I SYMBOL DATE <br /> - FIRE MONITORING PANEL REPLACEMENT SEA 03.25.24 THIS DESIGN AND/OR CHECKED FIRE ALARM SYSTEM DETAILS 9132326 03.25.24 0 <br /> SPECIFICATION IS APPROVED N IN TITLE SHEET E506 5 <br /> -ABOE//VG® APPROVED BY DEPT DATE N <br /> CHECKED <br /> APPROVED BUILDING 45-715 JOB NO� 9132326 COMP N0. <br /> APPROVED MDK EVERETT, WA DWG No. 45-715—E506 <br />