My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10829 19TH AVE SE STE 1A 2024-12-04
>
Address Records
>
19TH AVE SE
>
10829
>
10829 19TH AVE SE STE 1A 2024-12-04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2024 1:37:50 PM
Creation date
11/6/2024 11:57:18 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10829
Unit
STE 1A
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(E) POTTER PAD200-PD <br /> The Symbol of Protection Photoelectric Smoke Sensor <br /> Features <br /> • UL 268 7th Edition <br /> • Low profile,less than 2 inches with the base p <br /> • Wide selectable sensitivity range of 1.0 to 3.7%/foot <br /> • Sensor communicates sensitivity to control panel <br /> • UL listed smoke calibration and sensitivity <br /> • Optional locking tab to prevent unwanted removal <br /> • Simple DIP switch address setting,no programming tool <br /> required <br /> • LED alarm indicator <br /> • Product includes a 5 year warranty <br /> • UUKL Listed for Smoke Control O <br /> UL <br /> LISTED <br /> Description Technical Specifications <br /> The Photoelectric Smoke Sensor is a listed Analog Addressable smoke Operating Voltage 24 VDC <br /> sensor compatible with fire alarm control panels that utilize the Potter <br /> Addressable Device(PAD)protocol.The PAD200-PD is a low profile Detector Current Draw 300 µA <br /> smoke sensor with a wide sensitivity range.The sensor and base(not Alarm indicator 1 LED <br /> included)are made of a durable plastic in an off-white color to blend Alarm set-point range 1.0 to 3.7%/ft 3.6-12%/m <br /> in with the ceiling. <br /> n/o Installation temperature 32 to 120°F/ 0 to 49°C <br /> The PAD200-PD has a sensitivity range of 1.0 to 3.7 per foot and range <br /> is UL. The PAD200-PD features drift compensation and has built in <br /> dirty detector warning as well as. The PAD200-PD and the control Operating relative 0%to 93%(Non-condensing) <br /> panel communicate over a proven and robust digital communication humidity range <br /> path and the system analyzes the information at the particular device. Start-up time Max. 1 sec. <br /> The total polling speed is less than five(5)seconds,well under the UL Maximum number of <br /> requirements. addresses per loop 127 <br /> The sensor is compatible with any of the PAD series sensor bases and Maximum number of <br /> simply twists on. The PAD200-PD is addressed using DIP switches lighted indicators in 30 <br /> in the rear of the sensor and can be easily programmed in the field alarm per loop. <br /> without special tools. <br /> Color Eggshell White <br /> Setting the Address Weight(without base) 101g(3.56oz) <br /> Each addressable device on the SLC loop must have a unique address Dimensions(without Height: 1.35 in(34mm) <br /> from 1 to 127 to function properly. The address is set using DIP base) Diameter:3.93 in(100 mm) <br /> switches. <br /> Before connecting a device to the SLC loop, take the following <br /> precautions to prevent potential damage to SLC or device.Verify the <br /> following: <br /> 1. Power to the device is removed <br /> 2. Field wiring is correctly installed. <br /> 3. Field wiring has no open or short circuits. <br /> Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com <br /> 8830172-REV A 5/21 PAGE 1 OF 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.