Laserfiche WebLink
the CA-2 configuration: ADDR-134, ADDR-C4, ADDR-D4 IPDACT-2, IPDACT Internet Monitoring Module: Connects <br /> (below). to primary and secondary DACT telephone output ports for <br /> ADDR-64:Two-tier-sized door designed for use with the CA-2 internet communications over customer-provided Ethernet <br /> chassis configuration.ADDR Series doors are similar to CAB- connection. Requires compatible Teldat VisorALARM Central <br /> 4 Series "DR" doors, but a clear window space exposes the Station Receiver. Can use DHCP or static IP. See DN-60408. <br /> top two tiers of the CAB-4 enclosure. Use an SBB-B4 backbox IPCHSKIT: IP Communicator Chassis Mounting Kit. For <br /> with the ADDR-134. See DN-7045, DN-6857. mounting an IPDACT-2/2UD onto the panel chassis or CHS-4 <br /> ADDR-C4: Three-tier-sized door designed for use with the series chassis. Use IPENC for external mounting applications. <br /> CA-2 chassis configuration.ADDR Series doors are similar to IPSPLT:Y-adapter option allow connection of both panel dialer <br /> CAB-4 Series "DR" doors, but a clear window space exposes outputs to one IPDACT-2/2UD cable input. <br /> the top two tiers of the CAB-4 enclosure. Use an SBB-C4 IPENC: External enclosure for IPDACT, includes IPBRKT <br /> backbox with the ADDR-C4. See DN-7045, DN-6857. mounting bracket; Red;for black,order IPENC-B. <br /> ADDR-D4: Four-tier-sized door designed for use with the CA- IPGSM-4G: Internet and Digital Cellular Fire Alarm Communica- <br /> 2 chassis configuration. ADDR Series doors are similar to tor. Provides selectable configurable paths:cellular only, IP only, <br /> CAB-4 Series "DR" doors, but a clear window space exposes or IP primary with cellular backup. Connects to the primary and <br /> the top two tiers of the CAB-4 enclosure. Use an SBB-D4 secondary ports of a DACT. For Canadian applications order <br /> backbox with the ADDR-D4. See DN-7045, DN-6857. IPGSM-4GC. See DH-60769. <br /> DPA-1: Dress panel, used with the CA-1 chassis when config- NOTE:For other options including compatibility with retrofit equip- <br /> ured with a DVC-EM, DVC-KD,and CMIC-1. See DN-7045. ment,refer to the panel's installation manual,the SLC manual,and <br /> DPA-2: Dress Panel used with the CA-2 chassis assembly. the Device Compatibility Document. <br /> DPA-1A4: Dress panel, used with the CA-1 chassis when the System Specifications <br /> CMIC-1 is not used. Provides mounting options on right two <br /> bays for two ACS annunciators, or for blank plates. See DN- SYSTEM CAPACITY <br /> 7045. <br /> • Intelligent Signaling Line Circuits...........1 expandable to 10 <br /> ADP-4B:Annunciator dress plate. Mounts in rows 2, 3 or 4 of Intelligent detectors..........................................159 per loop <br /> a CAB-4 series enclosure. Used with ACS series annuncia- <br /> tors. Addressable monitor/control modules..............159 per loop <br /> BMP-1: Blank module for unused module positions. Programmable software zones.............................over 2000 <br /> • ACS annunciators <br /> DP-1 B: Blank dress panel. Provides dead-front panel for per CPU2-3030.......................32 address x 64 or 96 points <br /> unused tiers;covers DAA2/DAX series or AA-series amplifier. <br /> NOTE: The CPU2-3030 can support up to 96 annunciator <br /> BP24: Battery plate, required. address points per ACM-24AT/--48A. <br /> CHS-4L: Low-profile four-position Chassis. Mounts two AA-30 SPECIFICATIONS <br /> amplifiers. <br /> Primary Input Power: <br /> CHS-4N: Chassis for mounting up to four APS-6Rs. <br /> -AMPS-24: 110-120 VAC, 50/60 Hz,4.5 A maximum. <br /> CHS-6: Chassis used with the XP6 and XP10 Multi-Modules. -AMPS-24E:240 VAC,50/60 Hz,2.25 A maximum. <br /> Mounts up to six modules in any CAB-4 series row. <br /> DC Output: <br /> BB-100: Backbox for batteries and power supplies. The BB- <br /> 100 is used to mount up to two 100 AH batteries and power -Main 24 VDC: Up to 5.0 A <br /> supply, if needed. 30"(76.20 cm)wide x 25"(63.50 cm)high x -Aux 24 VDC: Up to 5.0 A <br /> 7.5"(19.05 cm)deep;depth includes door. -5 VDC: Up to 0.15 A. <br /> BB-200: Backbox for batteries and power supplies. Holds up Current draw(Standby/Alarm): <br /> to four 100 AH batteries (200 AH capacity)and power supply. -CPU2-3030D board:0.340 A. <br /> 30" (76.20 cm)wide x 36" (91.44 cm) high x 7.5" (19.05 cm) <br /> deep;depth includes door. -CPU2-3030ND board:0.120 A. <br /> NFS-LBB: Battery Box. The NFS-LBB is used to mount up to -LCM-320:0.130 A. <br /> two 55 AH batteries. Dimensions: Box: 24" (610 mm) wide x -LEM-320: 0.100 A. <br /> 14"(356 mm)high x 7.75"(197 mm)deep. Door:24.125"(613 -AMPS-24(E)`: 0.13 A. <br /> mm)wide x 14.25"(362 mm)high;door adds 0.0625"(approx. (Draws power from secondary power source only.) <br /> 1.6 mm)to depth. NOTE: See AMPS-24(E) Manual 51907 for a complete current <br /> BB-UZC: Backbox for housing the UZC-256 for applications draw calculation sheet and details of input and output values. <br /> where the UZC will not fit in panel enclosure. Black; for red, Battery charger range:7 AH-200 AH. Use separate cabinet <br /> order BB-UZC-R. See DN-3404. for batteries over 26 AH. <br /> SEISKIT-CAB: Seismic mounting kit. Required for seismic- Float Rate: 27.6 V. <br /> certified applications with NFS2-3030 and other equipment <br /> mounted in CAB-4 Series Enclosures. Includes battery bracket SHIPPING WEIGHT <br /> for two 26 AH batteries. • CPU2-3030D: 5.95 lb(2.70 kg). <br /> SEISKIT-LBB: Seismic kit for the NFS-LBB. Includes battery CPU2-3030ND:2.90 lb(1.32 kg). <br /> bracket for two 55 AH batteries. <br /> TEMPERATURE AND HUMIDITY RANGES <br /> OTHER OPTIONS This system meets NFPA requirements for operation at 0 - <br /> 411: Slave digital alarm communicator. See DN-6619. 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH <br /> 411UDAC: Digital alarm communicator. See DN-6746. (noncondensing) at 32°C ± 2°C (90oF ± 3°F). However, the <br /> useful life of the system's standby batteries and the electronic <br /> DN-7070:N•01/25/2016-Page 7 of 8 <br />