My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9602 EVERGREEN WAY 2024-11-08
>
Address Records
>
EVERGREEN WAY
>
9602
>
9602 EVERGREEN WAY 2024-11-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/6/2024 3:45:01 PM
Creation date
11/6/2024 3:44:22 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
9602
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
From: Kurtis Brown <br /> Sent: Wednesday,April 5, 2023 12:05 PM <br /> To: LUCASISMAEL@ICLOUD.COM <br /> Cc: Gordon Mosteller <br /> Subject: DOS Hermanos Chapines <br /> Attachments: FMFV2303-001_Regional-Fire-Marshals-Food-Truck-Inspection-Checklist.pdf <br /> Lucas Ismael, <br /> Please see the attached corrections. <br /> 1. Service is required for your commercial cooking extinguishing systems. <br /> All commercial cooking extinguishing systems shall be serviced by a qualified and certified <br /> individual not less than every 6 months. <br /> 2. Have your commercial kitchen hood(s),grease-removal devices,fans, ducts and other related <br /> equipment cleaned. <br /> In low-volume cooking operations such as places of religious worship, seasonal businesses and <br /> senior centers, hoods, grease-removal devices,fans, ducts and other related equipment shall be <br /> cleaned at an interval of not less than once every 12 months or as approved by the fire code <br /> official. Inspections shall be completed by qualified individuals that are trained with <br /> certifications establishing requirements for cleaning of commercial cooking operations. <br /> 3. Have your Compressed gas cylinder inspected. <br /> 4. Install a LP gas alarm. <br /> S. Provide portable fire extinguisher(s) <br /> Provide portable fire extinguisher(s)that comply with the following: <br /> • Sized at a minimum rating of a 2A:10BC(4.5+ pound ABC multi-purpose) <br /> • Located conspicuously along normal path of travel not more than 75 feet from any other <br /> extinguishers. <br /> • Mounted to the wall so that the top of the extinguisher is not more than 5 feet above <br /> the floor. <br /> • In full operational condition and provided with a service tag or dated by the <br /> manufacturer within the last 12 months. <br /> 6. Provide a Class K-rated portable fire extinguisher(s) <br /> Provide a Class K-rated portable fire extinguisher(s)that is conspicuously located and mounted. <br /> The Class K-rated extinguisher shall be in full operational condition and provided with a service <br /> tag or dated by the manufacturer within the last 12 months. <br /> 7. Multiple extension cords are connected and taped to one another. Replace existing cords with <br /> one cord that can be connected from the truck and directly into the receptacle. <br />
The URL can be used to link to this page
Your browser does not support the video tag.