My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8825 EVERGREEN WAY LOS POTRILLOS 2024-12-05
>
Address Records
>
EVERGREEN WAY
>
8825
>
LOS POTRILLOS
>
8825 EVERGREEN WAY LOS POTRILLOS 2024-12-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/5/2024 11:08:33 AM
Creation date
11/7/2024 8:56:35 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8825
Tenant Name
LOS POTRILLOS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
112
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 TRANS° <br /> Model Number Description <br /> Digit 1—Unit Function Digit 12,13—Service Sequence Digit 18—Through-the-Base Provisions <br /> Y=DX Cooling,Gas Heat *=Factory Assigned 0=No Through-the-Base Provisions <br /> A=Through-the-Base Electric <br /> Digit 2—Cooling Efficiency Digit 14—Fresh Air Selection B=Through-the-Base Gas Pipings <br /> C=Through-the-Base Electric and Gas Pipings <br /> S=Standard Efficiency 0=No Fresh Air <br /> A=Manual Outside Air Damper 0-50% Digit 19—Disconnect/Circuit Breaker(three- <br /> Digit 3—Refrigerant B=Motorized Outside Air Damper 0-50% phase only) <br /> C=Economizer,Dry Bulb 0-100%without 0=No Disconnect/No Circuit Breaker <br /> J=R-410A Barometric Relief2 1=Unit Mounted/Non-Fused Disconnect <br /> D=Economizer,Dry Bulb 0-100%with 2=Unit Mounted Circuit Breaker <br /> Barometric Relief2 <br /> Digit 4,5,6—Nominal Gross Cooling ° Digit 20—Convenience Outlet <br /> E=Economizer,Reference Enthalpy 0-100/o Di <br /> Capacity(MBh) without Barometric Relief2 <br /> 072=6 Ton F=Economizer,Reference Enthalpy 0-100% 0=No Convenience Outlet <br /> 090=7.5 Ton with Barometric Relief2 A=Unpowered 20A Convenience Outlet <br /> 102=8.5 Ton G=Economizer,Comparative Enthalpy B=Powered 15A Convenience Outlet <br /> 120=10 Ton 0-100%without Barometric Relief2 (three-phase only) <br /> 150=12.5 Ton H=Economizer,Comparative Enthalpy <br /> 180=15Ton <br /> 0-100%with Barometric Relief2 Digit 21—Communications Options <br /> 210=17.5 Ton K=Downflow Low Leak Economizer,Dry Bulb <br /> 240=20 Ton with Barometric Relief2 0=No Communications Interface <br /> M=Downflow Low Leak Economizer,Reference 1=Advanced Controller with BACnet® <br /> 300=25 Ton Communications Interface <br /> Enthalpy with Barometric Relief2 <br /> Digit 7—Major Design Sequence P=Downflow Low Leak Economizer, 2=Advanced Controller with LonTalk® <br /> Comparative Enthalpy with Barometric Relief2 Communications Interface <br /> R=Downflow Low Leak Economizer,Differential 3=Advanced Controller with Air-FiO <br /> Dry Bulb with Barometric Relief2 Communications Interface <br /> Digit 8—Voltage Selection Digit 15—Supply Fan/Drive Type/Motor Digit 22—Refrigeration System Option <br /> 3=208-230/60/3 0=Standard Motor 0=Standard Refrigeration System <br /> 4=460/60/3 1=Optional Oversized/High Static Motor A=Dehumidification Option,3 <br /> W=575/60/3 2=Single Zone Variable Air Volume with <br /> Digit 23—Controls Expansion Module <br /> Digit 9—Unit Controls <br /> Standard Motor <br /> 3=Single Zone Variable Air Volume with 0=None <br /> S=SymbioTm 700 Oversized/High Static Motor 1=XM-30 Expansion Module <br /> 4=Multiple Zone Variable Air Volume with <br /> Standard Motor 2=XM-32 Expansion Module <br /> Digit 10—Heat Type 5=Multiple Zone Variable Air Volume with 3=XM-30 and XM-32 Expansion Module <br /> Oversized/High Static Motor 4=XM-30 Expansion Module(Qty 2) <br /> 0=Base Model 5=XM-32 Expansion Module(Qty 2) <br /> A=Stainless Steel Gas Heat Digit 16—Hinged Service Access/Filters <br /> Digit 24—Smoke Detector <br /> Digit 11—Heating Capacity' 0=Standard Panels/Standard Filters <br /> A=Hinged Access Panels/Standard Filters 0=No Smoke Detector <br /> L=Low Gas Heat B=Standard Panels/2 inch MERV 8 Filters A=Return Air Smoke Detector2 <br /> M=Medium Gas Heat C=Hinged Access Panels/2 inch MERV 8 Filters B=Supply Air Smoke Detector' <br /> H=High Gas Heat D=Standard Panels/2 inch MERV 13 Filters C=Supply and Return Air Smoke Detectors',2 <br /> E=Hinged Access Panels/2 inch MERV 13 Filters <br /> Digit 17—Condenser Coil Protection <br /> 0=Standard Coil <br /> 1=Condenser with CompleteCoatTM <br /> 16 RT-PRC098B-EN <br />
The URL can be used to link to this page
Your browser does not support the video tag.