Laserfiche WebLink
0 TRANS° <br /> Model Number Description <br /> Digit 1—Unit Function Digit 12,13—Service Sequence Digit 18—Through-the-Base Provisions <br /> Y=DX Cooling,Gas Heat *=Factory Assigned 0=No Through-the-Base Provisions <br /> A=Through-the-Base Electric <br /> Digit 2—Cooling Efficiency Digit 14—Fresh Air Selection B=Through-the-Base Gas Pipings <br /> C=Through-the-Base Electric and Gas Pipings <br /> S=Standard Efficiency 0=No Fresh Air <br /> A=Manual Outside Air Damper 0-50% Digit 19—Disconnect/Circuit Breaker(three- <br /> Digit 3—Refrigerant B=Motorized Outside Air Damper 0-50% phase only) <br /> C=Economizer,Dry Bulb 0-100%without 0=No Disconnect/No Circuit Breaker <br /> J=R-410A Barometric Relief2 1=Unit Mounted/Non-Fused Disconnect <br /> D=Economizer,Dry Bulb 0-100%with 2=Unit Mounted Circuit Breaker <br /> Barometric Relief2 <br /> Digit 4,5,6—Nominal Gross Cooling ° Digit 20—Convenience Outlet <br /> E=Economizer,Reference Enthalpy 0-100/o Di <br /> Capacity(MBh) without Barometric Relief2 <br /> 072=6 Ton F=Economizer,Reference Enthalpy 0-100% 0=No Convenience Outlet <br /> 090=7.5 Ton with Barometric Relief2 A=Unpowered 20A Convenience Outlet <br /> 102=8.5 Ton G=Economizer,Comparative Enthalpy B=Powered 15A Convenience Outlet <br /> 120=10 Ton 0-100%without Barometric Relief2 (three-phase only) <br /> 150=12.5 Ton H=Economizer,Comparative Enthalpy <br /> 180=15Ton <br /> 0-100%with Barometric Relief2 Digit 21—Communications Options <br /> 210=17.5 Ton K=Downflow Low Leak Economizer,Dry Bulb <br /> 240=20 Ton with Barometric Relief2 0=No Communications Interface <br /> M=Downflow Low Leak Economizer,Reference 1=Advanced Controller with BACnet® <br /> 300=25 Ton Communications Interface <br /> Enthalpy with Barometric Relief2 <br /> Digit 7—Major Design Sequence P=Downflow Low Leak Economizer, 2=Advanced Controller with LonTalk® <br /> Comparative Enthalpy with Barometric Relief2 Communications Interface <br /> R=Downflow Low Leak Economizer,Differential 3=Advanced Controller with Air-FiO <br /> Dry Bulb with Barometric Relief2 Communications Interface <br /> Digit 8—Voltage Selection Digit 15—Supply Fan/Drive Type/Motor Digit 22—Refrigeration System Option <br /> 3=208-230/60/3 0=Standard Motor 0=Standard Refrigeration System <br /> 4=460/60/3 1=Optional Oversized/High Static Motor A=Dehumidification Option,3 <br /> W=575/60/3 2=Single Zone Variable Air Volume with <br /> Digit 23—Controls Expansion Module <br /> Digit 9—Unit Controls <br /> Standard Motor <br /> 3=Single Zone Variable Air Volume with 0=None <br /> S=SymbioTm 700 Oversized/High Static Motor 1=XM-30 Expansion Module <br /> 4=Multiple Zone Variable Air Volume with <br /> Standard Motor 2=XM-32 Expansion Module <br /> Digit 10—Heat Type 5=Multiple Zone Variable Air Volume with 3=XM-30 and XM-32 Expansion Module <br /> Oversized/High Static Motor 4=XM-30 Expansion Module(Qty 2) <br /> 0=Base Model 5=XM-32 Expansion Module(Qty 2) <br /> A=Stainless Steel Gas Heat Digit 16—Hinged Service Access/Filters <br /> Digit 24—Smoke Detector <br /> Digit 11—Heating Capacity' 0=Standard Panels/Standard Filters <br /> A=Hinged Access Panels/Standard Filters 0=No Smoke Detector <br /> L=Low Gas Heat B=Standard Panels/2 inch MERV 8 Filters A=Return Air Smoke Detector2 <br /> M=Medium Gas Heat C=Hinged Access Panels/2 inch MERV 8 Filters B=Supply Air Smoke Detector' <br /> H=High Gas Heat D=Standard Panels/2 inch MERV 13 Filters C=Supply and Return Air Smoke Detectors',2 <br /> E=Hinged Access Panels/2 inch MERV 13 Filters <br /> Digit 17—Condenser Coil Protection <br /> 0=Standard Coil <br /> 1=Condenser with CompleteCoatTM <br /> 16 RT-PRC098B-EN <br />