Laserfiche WebLink
Product Specifications <br /> MODEL 4YCC406OA1090A 4YCC406OA1115A Volts/Ph/Hz 208-230/1/60 208-230/1/60 <br /> RATED Volts/PH/Hz 208-230/1/60 208-230/1/60 F.L.Amps/L.R Amps 1.7/3.5 1.7/3.5 <br /> Performance Cooling CONSTANT CONSTANT <br /> 58000 58000 INDOOR FAN-TYPE <br /> BTUH(a) TORQUE ECM TORQUE ECM <br /> Indoor Airflow(CFM) 1760 1760 Dia.x Width(in.) 11.87 X 10.68 11.87 X 10.68 <br /> Power Input(KW) 4.94 4.94 Drive/No.Speeds DIRECT/3 DIRECT/3 <br /> EER/SEER(BTU/Watt- 11.50/14.00 11.50/14.00 CFM @ 0.0 in.w.g.(9) SEE FAN PERF TABLE SEE FAN PERF <br /> Hr.) TABLE <br /> Sound Power Rating 73.1 73.1 Motor-HP/R.P.M. 1/1050 1/1050 <br /> [dB(A)](b) Volts/Ph/Hz 208-230/1/60 208-230/1/60 <br /> PERFORMANCE <br /> HEATING(c) F.L.Amps 6.9 6.9 <br /> Input BTUH-1st Stage COMBUSTION FAN- CENTRIFUGAL CENTRIFUGAL <br /> (Natural Gas)(d) 90000 115000 TYPE <br /> AFUE 81 81 Drive/No.Speeds DIRECT/1 DIRECT/1 <br /> Temp.Rise-Min/Max Motor-HP/R.P.M. 1/34/3075 1/34/3055 <br /> (OF) 30/60 30/60 Volts/Ph/Hz 230/1/60 230/1/60 <br /> Orifice Qty/Drill Sz. 3/#37 3/#33 FLA .24 .25 <br /> (Natural Gas) FILTER/ <br /> POWER CONN.-V/ 208-230/1/60 208-230/1/60 FURNISHED NO NO <br /> Ph/Hz Type Recommended THROWAWAY THROWAWAY <br /> Min.Brch.Cir. <br /> Ampacity(e) 39.1 39.1 Recmd.Face Area(sq. <br /> Fuse Size-Max. <br /> ft)(h) 5.3 5.3 <br /> (amps) 60 60 REFRIGERANT R-410 R-410 <br /> Fuse Size-Recmd. 60 60 Charge(lbs.) 9.65 9.65 <br /> (amps) CHARGING <br /> COMPRESSOR SCROLL SCROLL SPECIFICATIONS <br /> VOLTS/PH/HZ 208-230/1/60 208-230/1/60 Subcooling 110 110 <br /> R.L.Amps-L.R.Amps 24.4/144.2 24.4/144.2 GAS PIPE SIZE(in.) 1/2 1/2 <br /> OUTDOOR COIL- SPINE-FIN SPINE-FIN DIMENSIONS H X D X W H X D X W <br /> TYPE Crated(in.) 50 X 47 X 62 50 X 47 X 62 <br /> Rows/F.P.I 2/24 2/24 <br /> WEIGHT <br /> Face Area(sq.ft.) 22.99 22.99 Shipping(lbs.)/Net <br /> Tube Size(in.) 3/8 3/8 (lbs.) 580/476 586/482 <br /> INDOOR COIL- PLATE FIN PLATE FIN (a) Rated in accordance with AHRI Standard 210/240.AHRI standard <br /> TYPE rating conditions are:80 D.B.67 W.B.entering air to indoor coil.95 D. <br /> Rows/F.P.I 4/15 4/15 B.entering air to outdoor coil. <br /> Face Area(sq.ft.) 5.0 5.0 (b) Sound Power values are not adjusted for AHRI 270-95 tonal <br /> corrections. <br /> Tube Size(in.) 3/8 3/8 Ratings shown are for elevations up to 2000 ft.For higher elevations <br /> Refrigeration Control EXPANSION VALVE EXPANSION VALVE reduce ratings at a rate of 4%per 1000 ft.elevation. <br /> (d) Convertible to LPG. <br /> Drain Conn.Size(in.) 3/4 FEMALE NPT 3/4 FEMALE NPT (e) This value is approximate.For more precise value,see Unit <br /> OUTDOOR FAN- SWEPT SWEPT Nameplate. <br /> TYPE M Standard Air-Dry Coil-Outdoor. <br /> DIA.(IN.) 28.25 28,25 (9) Based on U.S.Government Standard Tests. <br /> (h) Filters must be installed in return airstream.Square footages listed <br /> DRIVE/NO.SPEEDS DIRECT/1 DIRECT/1 are based on 300 f.p.m.face velocity.If permanent filters are used <br /> CFM @ 0.0 in.w.g.M 4800 4800 size per manufacturer's recommendation with a clean resistance of <br /> 0.05"W.C. <br /> Motor-HP/R.P.M 1/3/825 1/3/825 <br /> 4YCC4060A-SUB-1 F-EN 3 <br />