My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8600 18TH AVE W HEAD START 2025-09-30
>
Address Records
>
18TH AVE W
>
8600
>
8600 18TH AVE W HEAD START 2025-09-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/30/2025 1:55:49 PM
Creation date
11/7/2024 10:10:32 AM
Metadata
Fields
Template:
Address Document
Street Name
18TH AVE W
Street Number
8600
Unit
HEAD START
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 TRANE' <br /> Product Specifications <br /> OUTDOOR UNIT(a)(b) 4TWR4036G1000A (a) Certified in accordance with the Air-Source Unitary Air-conditioner <br /> POWER CONNS.—V/PH/HZ W 208/230/1/60 Equipment certification program,which is based on AHRI standard <br /> 210/240. <br /> MIN.BRCH.CIR.AMPACITY 19 (b) Rated in accordance with AHRI standard 270. <br /> BR.CIR.PROT.RTG.—MAX.(AMPS) 30 (0 Calculated in accordance with Natl.Elec.Codes.Use only HACR <br /> circuit breakers or fuses. <br /> COMPRESSOR CLIMATUFF@-SCROLL (d) This value shown forcompressor RLA on the unit nameplate and on <br /> NO.USED—NO.STAGES 1—1 this specification sheet is used to compute minimum branch circuit <br /> ampacity and max.fuse size.The value shown is the branch circuit <br /> VOLTS/PH/HZ 208/230/1/60 selection current. <br /> (e> No means no start components.Yes means quick start kit <br /> R.L.AMPS(d)—L.R.AMPS 14.7—72.2 components.PTC means positive temperature coefficient starter. <br /> FACTORY INSTALLED Optional kit shown. <br /> START COMPONENTS(e) NO(Uses BAYKSKT263) (f) Standard Air—Dry Coil—Outdoor(9) This value approximate.For more precise value see unit nameplate. <br /> INSULATION/SOUND BLANKET NO (h) Reference the outdoor unit ship-with literature for refrigerant piping <br /> COMPRESSOR HEAT NO length and lift guidelines.Reference the refrigerant piping software <br /> pub#32-3312-xx or refrigerant piping application guide SS- <br /> OUTDOOR FAN PROPELLER APG006-xx for long line sets or specialty applications(xx denotes <br /> latest revision). <br /> DIA.(IN.)—NO.USED 27.5—1 (1) The outdoor condensing units are factory charged with the system <br /> TYPE DRIVE—NO.SPEEDS DIRECT—1 charge required for the outdoor condensing unit,ten(10)feet of <br /> CFM @ 0.0 IN.W.G.(f) tested connecting line,and the smallest rated indoor evaporative coil <br /> 3440 match.Always verify proper system charge via subcooling(TXV/EEV) <br /> NO.MOTORS—HP 1-1/5 or superheat(fixed orifice)per the unit nameplate. <br /> MOTOR SPEED R.P.M. 825 <br /> VOLTS/PH/HZ 208/230/1/60 <br /> F.L.AMPS 0.64 <br /> OUTDOOR COIL—TYPE SPINE FINT" <br /> ROWS—F.P.I. 1-24 <br /> FACE AREA(SQ.FT.) 19.1 <br /> TUBE SIZE(IN.) 3/8 <br /> REFRIGERANT CONTROL EXPANSION VALVE <br /> REFRIGERANT <br /> LBS.—R-410A(O.D.UNIT)(s) 6 LBS.,12 OZ <br /> FACTORY SUPPLIED YES <br /> LINE SIZE—IN.O.D.GAS(h)(i) 7/8 <br /> LINE SIZE—IN.O.D.LIQ. 3/8 <br /> CHARGING SPECIFICATIONS <br /> SUBCOOLING 10OF <br /> DIMENSIONS H X W X D <br /> CRATED(IN.) 34.4 x 38.7 x 35.1 <br /> WEIGHT <br /> SHIPPING(LBS.) 248 <br /> NET(LBS.) 216 <br /> 4TWR4036G-SUB-1 F-EN 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.