1216 LOMBARD AVE 2024-12-04
>
Address Records
>
LOMBARD AVE
>
1216
>
1216 LOMBARD AVE 2024-12-04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2024 1:54:42 PM
Creation date
11/7/2024 2:00:33 PM
Metadata
Fields
Template:
Address Document
Street Name
LOMBARD AVE
Street Number
1216
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A I B C D E I F G H <br /> LOAD CALCS-TOTAL AMPS AVAILABLE MAX AL;UHIERATING <br /> BUS RATING 1 120% TOTAL MAIN BREAKER = MAX BREAKER SIZE CURRENT FOR HM-1200 600 30o CONDUCTOR SCHEDULE <br /> 200A X 1.2 = 240 - 200A 40A INVERTER NUMBERR OF OMINAL OUTPU COMBINED <br /> TYPE INVERTERS CURRENT TOTAL TOTAL CONDUCTORS GROUND <br /> HM-1200 2 X 5.0A = 10.00A WIRES IN MINIMUM MINIMUM <br /> COMBINER BOX PANEL SIZE CALCS HM-600 5 X 2.46A = 12.30A = 24.76A TAG ID CONDUIT WIRE SIZE TYPE,MATERIAL WIRE SIZE TYPE,MATERIAL <br /> CIRCUIT# TOTAL 125/o TOTAL BREAKER SIZE HM-300 2 X 1.23 A = 2.46A <br /> � NUMBER OF NUMBER OF NOMINAL OUTPUT o COMBINED q• s #12 AWG PV CABLE,CU #6AWG BARE,CU � <br /> MODULES MICROINVERTERS CURRENT TOTAL <br /> CIRCUIT 1(1 of 2) 2 1 X 2.46A = 2.46A x 1.25 = 3.08A _ _ <br /> 6 5 #12 AWG -, #8 AWG -.CU <br /> CIRCUIT 1(2 of 2) 8 2 5.OA - 10.00A x 1.25 - 12.50A - 15.58A - 20A BREAKER SIZE CALCS C 3 #8AWG THWN-2,CU #8 AWG THWN-2,CU <br /> MAX AC OPERATING CURRENT 125% TOTAL BREAKER SIZE D"" 4 #8 AWG THWN-2,CU #8 AWG 7HWN-2,CU <br /> CIRCUIT 2(1 of 2) 2 2 X 1.23A = 2.46A = 3.08A _ 15.38A = 2OA TAG A CABLE WILL BE RUN THROUGH ATTIC WHERE POSSIBLE "TAG D ONLY IF APPLICABLE' <br /> 24.76A x 1.25 x 30.95A = 35A <br /> CIRCUIT 2(2 of 2) 8 4 X 2.46A = 9.84A X 1.25 = 12.30A <br /> NOTES: <br /> 1. 200A UTILITY METER GLOBE ONLY.(EXISTING) <br /> 2. 200A LOAD CENTER.(EXISTING) <br /> 3. 60A RATED NON-FUSED LOCKABLE AC DISCONNECT.(NEW) <br /> 4. 125A RATED COMBINER PANEL.(NEW) <br /> N ALL CONDUIT SIZES ARE MINIMUM SIZES N <br /> ALL WIRE SIZES ARE FOR COPPER WIRE <br /> 2 ZNSHINE ZXM6-NH120-360M MODULES 8 ZNSHINE ZXM6-NH120-360M MODULES <br /> WITH HOYMILES HM-600 MICRO INVERTERS WITH HOYMILES HM-1200 MICRO INVERTERS <br /> ---- ------- -------- ---- ---- ---- ----� <br /> I <br /> (21 (11 (81 (4) (3) (21 (11 I <br /> I <br /> I <br /> I <br /> I <br /> _ _ _ I <br /> I <br /> M ti ~ ti W <br /> I <br /> I <br /> I <br /> UTILITY <br /> 2 ZNSHINE ZXM6-NH120-360M MODULE 8 ZNSHINE ZXM6-NH120-360M MODUL S SERVICE <br /> WITH HOYMILES HM-300 MICRO INVERTER WITH HOYMILES HM-600 MICRO INVERT IRS 120/240V <br /> (1 OF 2) (2 OF 2) I SINGLE PHASE <br /> II 1 <br /> (21 (11 (8) • • • (21 (11 <br /> II M <br /> II (N)240V/60A PV <br /> 125A LOAD CENTER, 4� <br /> I NEMA 3R RATED 200A RATED <br /> B (N)UTILITY <br /> zaaA MAIN SERVICE <br /> II AC DISCONNECT MAIN <br /> II 240V/60A NEMA 3R DISCONNEC PANEL <br /> II NON-FUSIBLE, 2 <br /> II II -LOCKABLE (E)LOADSVISIBLE <br /> II 20A LABELED <br /> II <br /> II —TO—A" <br /> II (N)PV OCPD <br /> II 2P-35A <br /> II <br /> II <br /> I I <br /> 3 Cn <br /> NEMA3R RATED u 35A LOAD-SIDE FACILITY GROUND <br /> JUNCTION BOX:SHALL SOLAR OCPD GROUND ROD <br /> COMPLY W/NEC 110.3 (Opposite end of the main disconnect <br /> &314.6 4 <br /> on the busbar-NEC 705.12(B)(3) <br /> DRAWN BY: DRAWING SCALE: <br /> CONFIDENT/AL-THE INFORMATION CONTAINED EMS NOT TO SCALE <br /> IN THIS PACKET AND SUBSEQUENT CUTSHEETS Tracey L. vojt DATE: DESIGN <br /> SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER <br /> SO L G C N ANYONE OUTSIDE SOLGEN POWER. NEITHER 5715 BEDFORD ST, 01/03/2023 <br /> SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 <br /> P O W E R THE RECIPIENT'S ORGANIZATION, EXCEPT IN PAGE# <br /> CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 1216 Lombard Ave, Everett, WA 98201 <br /> RESPECTIVE EQUIPMENT, WITHOUT WRITTEN PV 3 <br /> CONSENT FROM SOLGEN POWER. <br />
The URL can be used to link to this page
Your browser does not support the video tag.