Laserfiche WebLink
ABBREVIATIONS GENERAL NOTES INDEX OF DRAWINGS <br /> L ANGLE CFM CUBIC FEET PER MINUTE ELEC ELECTRIC GA GAUGE LH LEFT HAND PLAM PLASTIC LAMINATE SCD SEAT COVER DISPENSER TOG TOP OF CONCRETE ARCHITECTURAL '_-` ' <br /> q CENTER LINE CG CORNER GUARD ELEV ELEVATOR GALV GALVANIZED LL LIVE LOAD PWD PLYWOOD SCHD SCHEDULE TOP TOP OF PAVEMENT 1. DIMENSIONS ARE TO FACE OF STUD,CONCRETE OR CENTER LINE OF COLUMN, SYN `/ <br /> q DIAMETER OR ROUND Cl CAST IRON EVER EMERGENCY GB GRAB BAR LMS LIQUID MARKING PNL PANEL SD SOAP DISPENSER OR TOS TOP OF STEEL UNLESS OTHERWISE NOTED. CS COVER SHEET \\ `\_ <br /> • DEGREELLC <br /> S CJT CONTROL JOINT ENCL ENCLOSURE OR GL GLASS OR GLAZING SURFACE PNT PAINT STORM DRAIN TOSL TOP OF SLAB G GENERAL INFORMATION,SITE PLAN,LEGAL,VICINITY MAP,CODES <br /> # NUMBER OR POUND CLG CEILING ENCLOSED GLBM GLU-LAM BEAM LT LIGHT POL POLISH SECT SECTION TOW TOP OF WALL 2. DO NOT SCALE DRAWINGS DIMENSIONS GOVERN. AI1.1 A FLOOR PLAN:OVERALL WAREHOUSE T.I. <br /> t PLUS OR MINUS CJ CONSTRUCTION JOINT EQ EQUAL GC GENERAL CONTRACTOR LVT LUXURY VINYL TILE PR PAIR SF SQUARE FEET TPD TOILET PAPER A2.1 FLOOR PLANS:LEVELS 1 &2,ENLARGED TOILET PLANS <br /> 1 PERPENDICULAR CLK CAULKING EQPT EQUIPMENT GND GROUND LWC LIGHT WEIGHT CONCRETE PRCST PRECAST SHT SHEET DISPENSER 3. VERIFY ALL EXISTING CONDITIONS,DIMENSIONS,DETAILS,ETC.NOTIFY ARCHITECT A3.1 DOOR TYPES,WALL TYPES&SCHEDULES • • <br /> R PLATE CLR CLEAR ESEW EMERGENCY SHOWER/ GWB GYPSUM WALL BOARD MAS MASONRY PST POUNDS PER SQUARE SHTG SHEATHING TPH TOILET PAPER HOLDER OF ANY AND ALL DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. A5.1 INTERIOR ELEVATIONS,TOILET ROOM HEIGHT DIAGRAM&PLUMBING SCHEDULE ARCHITECTURE,DESIGN <br /> AB ANCHOR BOLT CMU CONCRETE MASONRY EYE WASH GYP GYPSUM MATL MATERIAL FOOT SIG SOLAR INSULATED TPTN TOILET PARTITION ARA REFLECTED CEILING PLANS(RCP):LEVELS 1 &2,ENLARGED TOILET RCPS • • • <br /> PLE <br /> AC ACOUSTICAL OR ASPHALT UNIT EST ESTIMATE HIP HOSE BIB MAX MAXIMUM PSI POUNDS PER SQUARE GLAZING TS TUBULAR STEEL 4. WHEN CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE A7.1 ENLARGED STAIR PLANS&DETAILS <br /> CONCRETE CNTR COUNTER EXH EXHAUST HBD HARD BOARD ME MACHINE BOLT INCH SIM SIMILAR TV TELEVISION WORK,DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK.IF QUESTIONS A9.1 INTERIOR DETAILS <br /> A/C AIR CONDITIONING CO CLEANOUT EXP EXPANSION HC HOLLOW CORE OR MUD MEDIUM DENSITY PT PRESSURE TREATED SO SINK TYP TYPICAL CANNOT BE RESOLVED IN THIS MANNER,CONTACT THE ARCHITECT. <br /> ACM ALUMINUM COMPOSITE COL COLUMN EX/EXIST EXISTING HANDICAP OVERLAY PTO PAPER TOWEL SLR SEALER ILL UNDERWRITERS STRUCTURAL <br /> MATERIAL GONG CONCRETE EXP EXPOSED HD HAND DRYER MDF MEDIUM DENSITY DISPENSER SND SANITARY NAPKIN LABORATORY 5. VERIFY ELEVATIONS&LOCATIONS TO BE JOINED BEFORE CONSTRUCTION.CONTACT 12503 NE Bel-Red Road,Suite 100 <br /> ACP ACOUSTICAL PANEL CONN CONNECTION EXT EXTERIOR HDR HEADER FIBERBOARD PTD/R PAPER TOWEL DISPENSER UON UNLESS OTHERWISE ARCHITECT IF THEY DIFFER FROM THOSE SHOWN ON DRAWINGS. SOT GENERAL NOTES Bellevue,WA 95005 <br /> ACT ACOUSTICAL TILE CONSTR CONSTRUCTION FA FIRE ALARM HDWD HARD WOOD MECH MECHANICAL DISPENSER AND SNR SANITARY NAPKIN NOTED SO.2 TESTING&INSPECTION NOTES <br /> ADD ADDITIVE CONT CONTINUOUS FB FLAT BAR HOWE HARDWARE MEMB MEMBRANE RECEPTACLE RECEPTACLE UR URINAL 6. ALL ROUGH-INS TO BE APPROVED PRIOR TO FRAMING INSPECTION. SO.3 TYPICAL DETAILS p 425 646 1818 f 425 646 4141 <br /> ADH ADHESIVE CORR CORRIDOR FBD FIBER BOARD HIM HOLLOW METAL MI METAL PTN PARTITION SKI SEALANT VAR VARIES S1.1 FOUNDATION&FRAMING PLAN <br /> AD J ADJACENT CPT CARPET FBO FURNISHED BY OTHERS HORIZ HORIZONTAL MEZZ MEZZANINE PTR PAPER TOWEL SPEC SPECIFICATION VCT VINYL COMPOSITION TILE 7. MECHANICAL.ELECTRICAL.AND PLUMBING ARE BIDDER DESIGN.PORTIONS OF THIS S1.2 FOUNDATION-FLOOR NOTES <br /> ADJT ADJUSTABLE CT CERAMIC TILE FCIC FURNISHED BY HR HOUR MFR MANUFACTURER RECEPTACLE SPGL SPANDREL GLASS VENT VENTILATOR WORK SHOWN ON DRAWINGS IS FOR DESIGN INTENT OR FOR COORDINATION ONLY. S2.1 FOUNDATION DETAILS <br /> AFF ABOVE FINISH FLOOR CTR CENTER CONTRACTOR INSTALLED HT HEIGHT MH MAN HOLE PVC POLYVINYL CHLORIDE SO SQUARE VERT VERTICAL S3.1 FLOOR FRAMING DETAILS <br /> AGG AGGREGATE CTSK COUNTER SINK BY CONTRACTOR HTG HEATING MIN MINIMUM PVMT PAVEMENT SS SOLID SURFACING VEST VESTIBULE 8. MECHANICAL DESIGN/BUILD CONTRACTOR SHALL PROVIDE A MECHANICAL <br /> AL ALUMINUM CY CUBIC YARD FCTY FACTORY HVAC HEATING/VENTILIATION/ MIR MIRROR QT QUARRY TILE SST STAINLESS STEEL VNR VENEER VENTILATION SYSTEM CAPABLE OF SUPPLYING THE MINIMUM OUTDOOR AIR <br /> ALT ALTERNATE D DEEP,DEPTH FD FLOOR DRAIN AIR CONDITIONING MISC MISCELLANEOUS R RISER SSK SERVICE SINK VR VAPOR RETARDER QUANTITIES SPECIFIED IN THE 2018 IMC WITH WASHINGTON AMENDMENTS. <br /> AP ACCESS PANEL DEL DOUBLE PON FOUNDATION AftHOT WATER HEATER MO MASONRY OPENING RA RETURN AIR STA STATION W WEST <br /> APPROX APPROXIMATE DEPT DEPARTMENT FE FIRE EXTINGUISHER IBC INTERNATIONAL BUILDING MTD MOUNTED RAD RADIUS STC SOUND TRANSMISSION W/ WITH 9, ELECTRICAL DESIGN/BUILD CONTRACTOR SHALL PROVIDE AND INSTALL MEANS OFARC I I BRIDGE <br /> AWE AGOUSTICALRWALL FABRIC OFAL DRINKING FOUNTAIN AND DETAIL FEC FIRE CABINET ID <br /> ID N°DE SIIDE DIAMETER/ NULL MULLINORTH IRS R&S ROD`&NSHELFE STN STAIN WC WATERUCLOSET ANDDE1013LUMINATION AND ILLUMINATED EXIT SIGNS PER 2018 IBC SECTIONS 1008 PROJECT INFORMATION <br /> AWP ACOUSTICAL WALL PANEL BOTTLE FILLER FF FINISHED FLOOR DIMENSION NIC NOT IN CONTRACT RD ROOF DRAIN STD STANDARD WD WOOD <br /> BD BOARD DIA DIAMETER FIN FINISH IS INSULATED GLASS NO/# NUMBER RD/O ROOF DRAIN OVERFLOW STL STEEL WOO WINDOW 10. PER IBC 106.1.DESIGN LIVE LOADS FOR THE MEZZANINE FLOORS"SHALL BE PROJECT SCOPE: NEW FAST SIGNS 2 STOREY OFFICE TENANT IMPROVEMENT WITHIN <br /> BETW BETWEEN DIAG DIAGONAL FL FLOOR IN INCH NOM NOMINAL REBAR REINFORCING BAR STOR STORAGE WE WIDE FLANGE CONSPICUOUSLY POSTED BY THE OWNER IN THAT PART OF EACH STORY IN WHICH EXISTING THE BP EVERETT 500 SHELL Bridge Industrial <br /> BLDG BUILDING DIM DIMENSION FIG FLASHING INCL INCLUDE NRC NOISE REDUCTION REF REFERENCE,REFLECTED STRL STRUCTURAL WG WIRE GLASS THEY APPLY,USING DURABLE SIGNS. IT SHALL BE UNLAWFUL TO REMOVE OR <br /> BLK BLOCK DISP DISPENSER FLUOR FLUORESCENT INSUL INSULATION COEFFICIENT REFR REFRIGERATOR SUSP SUSPENDED WH WAREHOUSE DEFACE SUCH NOTICES."THE DESIGN LIVE LOADS CAN BE FOUND IN THE PROJECT ADDRESS: 5900 36TH AVE WEST EVERETT,WA 98203 10655 NE 4th Street <br /> BLKG BLOCKING DMPF DAMP PROOFING FOC FACE OF CONCRETE TNT INTERIOR NTS NOT TO SCALE REINF REINFORCED SV SHEET VINYL VIM WIRE MESH STRUCTURAL ENGINEER SET Suite 212 <br /> BM BEAM ON DOWN FOP FACE OF FINISH INV INVERT CA OVERALL RED REQUIRED SYM SYMMETRICAL WOM WALK OFF MAT BUILDING OWNER: BRIDGE INDUSTRIAL Bellevue,WA 98004 <br /> ERG BEARING DR DOOR OR DRAIN FOIC FURNISH BY OWNER JAN JANITOR OBS OBSCURE REV REVISION SWC SPECIAL WALL COVERING Wp WATER PROOF <br /> BO BOTTOM OF DWR DRAWER INSTALL BY CONTRACTOR JST JOIST OC ON CENTER RH RIGHT HAND OR ROBE T TREAD WPT WORKING POINT 11, SEPARATE PERMIT SUBMITTALS: 10655 NE 4TH STREET,SUITE 212 <br /> HOT BOTTOM DS DOWNSPOUT FOOD FURNISH BY OWNER JT JOINT OD OUTSIDE DIAMETER HOOK TB TOWEL BAR WR WATER RESISTANT BELLEVUE,WA 98004 <br /> / DEMOLITION PERMIT FOR EXISTING STRUCTURES <br /> BSMT BASEMENT DIN DISHWASHER INSTALL BY OWNER NO KNOCK OUT DIMENSION RESIL RESILIENT T&B TOP&BOTTOM WSCT WAINSCOT FIRE ALARM MEETING NFPA 72 REQUIREMENTS PROPERTY TAX NO.: 28040300200100 <br /> BUR BUILT UP ROOF DWG DRAWING FOS FACE OF STUD KS KNEE SPACE OH OVERHEAD RIO ROUGH-IN ONLY T&G TONGUE&GROOVE WT WEIGHT SPRINKLERS MEETING NFPA 13 REQUIREMENTS <br /> CAB CABINET E EAST FPW FREEZE PROOF WALL LAB LABORATORY OPH OPPOSITE HAND RM ROOM TG TEMPERED GLASS WWF WELDED WIRE FABRIC WATER SUPPLY FOR NEW T.I.FIRE SPRINKLER SYSTEMS ARCHITECT: SYNTHESIS ARCHITECTS PLLC <br /> CB CATCH BASIN EA EACH HYDRANT LAM LAMINATE OPNG OPENING RO ROUGH OPENING THK THICK XFMR TRANSFORMER ELECTRICAL 12503 NE BEL-RED ROAD,SUITE 100 <br /> CBU CEMENTITIOUS BACKER EB EXPANSION BOLT FS FULL SIZE LAV LAVATORY OPP OPPOSITE RT RESILIENT/RUBBER TILE THR THRESHOLD YD YARD SEWER PERMIT BELLEVUE,WA 98005 <br /> UNIT Ed EXPANSION JOINT FT FEET LB LAG BOLT PBD PARTICLE BOARD RUB RUBBER TIG TEMPERED INSULATED <br /> CMT CEMENT EIFS EXTERIOR INSULATED FIG FOOTING LF LINEAL FOOT PERP PERPENDICULAR RWL RAIN WATER LEADER GLAZING HVAC,PLUMBING CONTACT:RANDY BROWN I PRINCIPAL ARCHITECT <br /> CL CENTER LINE FINISH SYSTEM PURR FURRING L LONG,LENGTH PL PLATE OR PROPERTY S SOUTH TKBD TACK BOARD STRUCTURAL JOISTS (425)646-1818 OFFICE I (206)228-8000 CELLPHONE <br /> CER CERAMIC EL ELEVATION PUT FUTURE LG LAMINATED GLASS LINE SC SOLID CORE TO TOP OF ENERGY CODE STRUCTURAL: CAHBL <br /> ONTACT:LARRY HIGGENS I STRUCTURAL ENGINEER <br /> SYMBOLS TACOMA,WA 98403 STRE ,SUITE 200 <br /> 1. ENERGY CODE COMPLIANCE: (253)383-2422 <br /> WAREHOUSE AREAS: SEMI-HEATED <br /> NORTH OFFICE AREAS: CONDITIONED <br /> A COLUMN ("� ��I��1 ��^� COMPLIANCE METHOD: COMPONENT <br /> LINE/GRID Z J) REVISION/CLOUDED AREA J_L�/� DETAIL IDENTIFICATION/ PROJECT NORTH 2. INSULATION REQUIREMENTS: <br /> IT IT A9�.1 SHEET NUMBER <br /> ROOF INSULATION: RIGID CONTINUOUS OVER DECK:R-30 <br /> MATCH LINE WALL INSULATION: NONE <br /> I Apt EXTERIOR GLAZED PERIMETER SLAB INSULATION: NONE <br /> INTERIOR ELEVATION <br /> A01 DOOR NUMBER 1 OPENING N0. SKYLIGHTS: U-0.40 <br /> A51 O h IDENTIFICATION/ DOORS: U-0.35 <br /> POINT OR DATUM POINT <br /> WORK POINT,CONTROL SHEET NUMBER EQUIPMENT EQ-1 SECTIONAL DOORS: R-1 <br /> 16 <br /> Y IDENTIFICATION ROLL-UP DOORS: R-16 •1 KEY NOTE FINISH FIXED WINDOWS: U-0.38 <br /> I-I 3 SECTION IDENTHCATION/ OFFICE ROOM IDENTIFICATION/ PNT 1 IDENTIFICATION METAL ENTRANCES: U-0.38 <br /> tt 1 WALL TYPE A3.1 SHEET NUMBER 101 NUMBER - <br /> I I X- FENCE LINE 3. SHADING COEEFICIENTS <br /> SEE SHEET A3.1 <br /> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br /> 4. EFFICIENCY PACKAGES: <br /> TOTAL POINTS REQUIRED: 6 - - - - - - - - - - - - - - - - - <br /> C406.2 MORE EFFICIENT HVAC EQUIPMENT 2 <br /> C406.3 REDUCED LIGHTING POWER 4 <br /> 5. THE AIR LEAKAGE RATE OF THE BUILDING ENVELOPE(S)SHALL NOT EXCEED 0.25 CODE INFORMATION - - - - - - - <br /> CFM/FT2 AT A PRESSURE DIFFERENTIAL OF 0.3 INCHES WATER GAUGE. A BLOWER T.I.2018 IBC <br /> DOOR TEST SHALL BE CONDUCTED FOLLOWING ALL PROCEDURES OUTLINED IN 2018 Code Edition: , <br /> WSEC C402. 2018 IBC,2018 IFC,2018 IMC,2018 UPC,2018 WSEC AC 51-1105.1.2. ) <br /> ICC/ANSI A117.1-2009;WASHINGTON STATE AMENDMENTS TO THE ABOVE <br /> (WAC 51-50). - 03 12 24 PRELIMINARY PRICING SEr <br /> In Amended by Local Jurisdiction Yes X No - 03 07 24 TENANT,REVIEW PRINTING <br /> Construction: New_ Addition_ Alteration X Repair_ ISSUE No. DATE ITEM <br /> LEGAL DESCRIPTION BUILDING CLASSIFICATION <br /> A. Occupancy Classification(Sect.302) B/S-1 PROFESSIONAL <br /> BP EVERETT 500 PROPERTY:NE AND SE 1/4,NE 1/4,SECTION 03,TOWNSHIP 28 NORTH,RANGE 4 B. Construction Classification(Section 601) <br /> EAST,V.M. 1. Type of Construction III-B <br /> 2. Automatic Sprinklers Provided ESFR Yes -No <br /> C. Seismic Design Category D <br /> OCCUPANCY LOAD(Per IBC Table 1004.5, PROGRESS <br /> VICINITY MAP NORTH FIRST FLOOR <br /> P R I N T I N G <br /> SPACE FUNCTION LOAD FACTOR AREA OCCUPANT LOAD <br /> - - - - - - - - - - - - Office Business 150 SF 1,879 12.53 Persons March 12,2024 <br /> 8 3 1' 8n 8 \ POSSESSION SOUND I Office Assembly Conference 1/15 SF(NET) 339 22.60 Persons <br /> m=m mem m�m n3 me_m Oda+ �i. 6 Warehouse Warehouse 500 SF 44,657 446.57 Persons <br /> IIIIII I I _e _e_ I N,aE VUaoca '� _ - <br /> SEGDND"°GR NOT FOR CONSTRUCTION <br /> SPACE FUNCTION LOAD FACTOR AREA OCCUPANT LOAD <br /> W� Office Business 150 SF 1,403 9.35 Persons <br /> N <br /> EXISTING I I Office Assembly Conference 1/15 SF(NET) 162 10.80 Persons • INFORMATION WAREHOUSE ° �� 54TH ST S. PLUMBING CALCULATIONS <br /> -B"E" - I FAST SIGNS T.I. <br /> (Per Washington state amendments to IBC Table 29021) <br /> NOTAPART EXISTING /�/i ii, 9 56TH95N <br /> F THIS PERMIT I WAREHOUSE /� �/ I p- SPACE OCCUPANT LOAD INC LAV OF <br /> m SHELL NEW OFFICES ,o� Office .7 .54 <br /> SPA Warehouse 446.57 4.47 4.47 EXISTING)l.0 <br /> BUILDING B - BP EVERETT 500 <br /> BOEING ESRC TOTAL(2 LEVELS) 468.45 5.34 5.01 3.0 5900 36TH AVE W SUITE: 400 <br /> Required Rye 4GO(3.34) 3.00(2.92) EVERETT, WA 98203 <br /> EVERETT WASHINGTON PROJECT DF or Bottle Filler Required by WA state amendments(1 for let 150 OCCUPANTS) <br /> NEW I UNION (Per Washington State GENDER NEUTRAL FACILITIES ALLOWANCE PER 2018 IBS 2902.2.2) <br /> WAREHOUSE I TOTAL FIXTURES EXISTING 1 1 1.0 SHEET INFORMATION <br /> TOILETS 5I TOTAL FIXTURES PROVIDED T.I.PROJECT: 6 6 2.0 <br /> __ Lill <br /> TOTAL FIXTURES: 7 7 3.0 RELEASE FOR PROGRESS PRINTING <br /> So4 � 00�00000000GENERAL INFORMATION. SITE PLAN <br /> O <br /> DESIGNED By .DRAWN,By <br /> 1 RENEWED BY _ _ _ _ _ APPROVED Br�_ <br /> A1.1 DATE: 03.12 24 <br /> SHEET N0: G1.1 <br /> PROJECT No: 201813.20.111 <br /> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br /> 4 PARTIAL SITE PLAN: EXISTING BUILDING B - BP EVERETT 500 + NEW FAST SIGNS T.I. NORTH <br /> I SCALE: 1"=50'-0" 0 12.5 25 50' 100 15T (1) <br /> c 0 2024 SYNTI IONSPLLC <br />