RANDY BROWN <br /> 5900 36TH AVE W BLDG B SUITE 400 <br /> B2403-091 <br /> b. Two complete sets of revised construction drawings, cloud all updated parts. <br /> c. Two copies of supplemental structural calculations (only if required by reviewer). <br /> Submittal documents should contain sufficient information and detail to review the proposed project <br /> for compliance with the adopted building codes. Upon submittal of the revised documents, your <br /> application will be given priority and the review will recommence. <br /> General (Comments provided by Benjamin Monk, P.E.) <br /> 1. The mezzanine framing plan provided on sheet S1.1 appears to be cropped in such a way <br /> that specific engineering notation for the purpose of construction cannot be read. Please <br /> revise, and any other margin errors alike, per section 107.2 of the 2018 IBC. <br /> Architectural (Comments provided by Yin Lu) <br /> 2. Please confirm if this is the initial TI of the shell building? Also, please confirm no demolition <br /> scope at all. <br /> 3. On sheet G1.1, Plumbing calculation is confusing. Office occupant load = <br /> 12.53+22.60+9.35+10.80 = 55.28. Required per sex is 4.00(3.34) which is confusing too. I <br /> have hard time to figure out how calculation could end up with 3.34 and 2.92. Please review <br /> the calculation, and demonstrate the calculation process, and update the plumbing <br /> calculation accordingly. <br /> 4. On sheet G1.1, new level 2 could not fit in IBC 505 mezzanine definition due to the <br /> openness. So, level 2 is an addition to existing total floor area, please provide proposed <br /> addition floor area and existing building floor area accordingly. <br /> 5. In 2/A2.1, accessible stall appears could not fit 60" dia. turning floor clearance. Please <br /> dimension restroom partition accordingly. <br /> Structural (Comments provided by Benjamin Monk, P.E.) <br /> 1. Please provide anchorage calculations for the connections between the existing walls/beams <br /> and any new structural elements whose reactions subject existing elements to new loading. <br /> Additionally, please provide calculations which apply structural analysis to the reactions <br /> propagated throughout the existing building elements due to the alteration in a manner <br /> which provides a complete load path (see Section 1.4 of ASCE 7-16). Alternatively, provide <br /> an evaluation meeting the provisions of Sections 503.3 and 503.4 of the 2018 IEBC (or via <br /> non-prescriptive methods) that shows that the addition will not require retrofit to the <br /> existing structure due to either gravity or seismic. <br /> 2. It appears that Details 4/S3.1 and 5/S3.1 show a Simpson HTT hold-down which is not <br /> shown on the architectural plans and may impede the walkways/rooms of the mezzanine <br /> floor. Please coordinate this design with the architectural sheets. <br /> 3. The Red-I45TI Joist product calculations appear to specify that the top sheathing is to be <br /> glued to the top flange of the I-Joist, but this is not communicated in the drafted details. <br /> 3200 Cedar Street © 425.257.8810 permitservices@everettwa.gov <br /> Everett, WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page 2 of 3 <br />