GEOT E S T I Oak '.SZ' <br /> Bellingham�Arlington Oak Harbor <br /> wvvw.geotest-inc.com <br /> RMA <br /> EXPANSION ANCHOR INSPECTION REPORT <br /> PROJECT: Bridge Point Everett 500- Fastsigns TI JOB#: 24-1489 <br /> ADDRESS: 5900 36th Avenue West, Everett, WA REPORT#: EA001 <br /> PERMIT#: B2403-091 DATE: 7/1/2024 <br /> CLIENT: Bridge Industrial PAGE#: 1 of 3 <br /> CONTRACTOR: Northway Construction Inc. INSPECTOR: Jacob Lee <br /> Item(s) Inspected Location <br /> (6)5/8"X 6"Simpson Titen HD Anchors for Beam Bucket Level 2,Gridline L.5/1 <br /> (6)5/8"X 6"Simpson Titan HD Anchors for Beam Bucket Level 2,Gridline L.8/1 <br /> (6)5/8"X 6"Simpson Titan HD Anchors for Beam Bucket Level 2,Gridline M/1.5 <br /> Reference Drawing(s): Stamped and approved Structural Drawing Detail 3/S3.1 <br /> Item(s) Inspected Comments <br /> Base Material Condition Uncracked Mature Concrete <br /> Drill Bit Type 5/8"Diameter Concrete Bit <br /> Hole Diameter/Depth /� 5/8" <br /> Hole Cleanliness(If Applicable) N/A <br /> Anchor Type/Name/Dimensions /� Simpson Titen HD 5/8"X 6" <br /> Anchor Spacing/Edge Distance /� 6 1/4"Height and 1'-0 1/2"Length <br /> Anchor Embedment �/f 6" <br /> Anchor Torque/Displacement <br /> Anchor ICC-ES Report ESR-2713 <br /> Other El <br /> The above items were conforming V Nonconforming Items(see below) <br /> Comments: GeoTest was on-site to provide special inspection of the installation of the screw <br /> anchors for Level 2 beam pockets. The weather conditions were approximately 63°F and clear <br /> skies. The items listed above were installed per the approved plans and the manufacturer's <br /> installation instructions. The results of our inspections were discussed with the contractor prior <br /> to leaving the site. GeoTest will return upon request for further inspections. <br /> 5 6�, <br /> COPIES:bfox@rmacompanies.com,brian@northwayinc.com,jason@northwayinc.com,smayes@bridgeindustrial.com Reviewed by <br /> This report shall not be reproduced except in full,without the written approval of GeoTest Services,Inc. <br />