Laserfiche WebLink
Permit#: B2308-080 <br /> —J .,. OW Address: PACIFC831 O RIDGE-H ST SW <br /> HLLC UNIT A o <br /> \� App.Date: 8/31/2023 <br /> ! _ Permit Type: RESIDENTIAL BUILDING c <br /> c B ENT N Subtype: NEWTOWNHOUSE UNIT(1 DWELLING ..O SQUARE <br /> UNfT) <br /> a <br /> PROJECT SITE Description: NEW TOWNHOUSE,UNITA fY-BE <br /> BUILDING ' E- - 3 T O W N H O M E S SQUARE BUILDING E,UNIT A <br /> Permit#: B2308-081 <'y <br /> Site Address: 1831100TH ST SW UNIT B '-% <br /> SOOTH STREET SW_ , � <br /> Owner: PACIFIC RIDGE-DRH LLC <br /> ��P m MA Wp" r� <br /> Apo.Date- 8/31/2023 � Z <br /> Vp4' ���EPE(I /� Permit7ype. RESIDENTIAL BUILDING w <br /> �OH"VA"9g5 -- SubNPe: NE�TOWNHOUSE UNIT(1 DWEWNG <br /> UN <br /> Description: NEWTOWNHOUSE COMMUNITY-BENTON <br /> 0 <br /> SQUARE BUILDING E,UNIT B <br /> Permit#: B2308-082 _001_ _ _ <br /> Site Address: 1111 3 7H ST SW UNIT <br /> Owner: PACIFIC RIDGE-DRHLLC <br /> - <br /> ' Apo.Date: 8/31/2023 = <br /> I I <br /> Permit7ype: RESIDENTIAL BUILDING `mm <br /> -- _ EVERETT FIRE DEPT.REVIEW �1 - _ Sub i. ! type: NEW TOWNHOUSE UNIT(1 DWELLING <br /> �PPROVED -._- - _ � UNIT) <br /> D APPROVED WITH CHANGES NOTED Description: NEW TOWNHOUSE COMMUNITY-BENTON - <br /> i I <br /> z <br /> REVISE AND RESUBMIT _ SQUARE BUILDING ,UNIT C <br /> VICINITY PLAN <br /> E <br /> ❑REJECTED: <br /> NOT TO SCALE _ eviewe <br /> E <br /> ❑SE ATTACHED CHECKLIST/HANDOUT - - <br /> i <br /> p _ R 8 Date'?L <br /> I The issuance of aermit shall not GROSS DWELLING UNIT AREAS: NORTH cbe ancel Cruet as authority to violate. <br /> - Office Set _lob Site Set <br /> cancel or set aside any provision of <br /> the Everett Fire Code or other <br /> applicable feguiations or laws.The ! — CITY OF:EVERETT atT - <br /> issuance of a permit based on -__ E I 1C r <br /> construction ocuments and other --_- -- 9 R,J E!!t_D FOa.P-R.' <br /> r ent the Fire Code - ---- awlewn smeaule data shall not prevent <br /> ha P <br /> requiring 'on <br /> Offieel from requ g the correction <br /> of errors. —- ---- <br /> UN - <br /> THESEDOCUMENTSHAVENOTBEEN <br /> IT B 2ND FL- - I I i <br /> CONDITIONED 3RD FL <br /> IO APPROVED FOR THE ISSUANCE OF <br /> 1ST FL- CONDITIONED I _- - - <br /> UNCONDITIONED 624 SF <br /> PUBLIC WORK,MECHANICAL,FIRE <br /> SUPPRESSION,ELECTRICAL OR <br /> 535SF 627 SF UNfTBMODINTERIOR-CONDITIONED — ,i _ - ® PLUMBING ERMITS <br /> Name Area APPROVED �D�ekwmem � -- -- <br /> 1ST FL-CONDITIONED 96 SF Office at Communay.Planning&Econorn ---- --_ -- - <br /> `' 1STFL-CONDITIONED 62asF PLANNING DEPARTMENT -- Q <br /> MEN <br /> n, 'l y� r� �}��} �} M <br /> j ❑ 3RD FL-CONDITIONED 627 SF " pATE:12-6-z3 - -__ u D Lti�lti�V I \ Q <br /> 1347 SF NAME: <br /> :iU6 3 1 2023 D � <br /> CITY OF EVERETT ~ <br /> Permit Services <br /> PROJECT DATA: CLIMATIC & GEOGRAPHIC DESIGN CRITERIA: W <br /> PREVIOUS APPROVALS&ASSOCIATED PERMITS: PREAPP20-005: 00480600102000 O <br /> PREAPP21-025: 00480600102000 Ground Wind Desi n Seismic suNecttodama efrom WINTER ICE SHIELD AIR MEAN <br /> Snow Design FLOOD REVII22-025: 00480600102000 S ed To re hic s frost line DESIGN UNDER- FREEZING ANNUAL <br /> Pe Po9 P 9 <br /> REV1122-029: 00480600102000 Load m h effects Category weathering de h termite TEMP. LAYMENT HAZARDS IN TEMP. <br /> PROJECT DESCRIPTION: CONSTRUCT 5 BUILDINGS-23 NEWATTACHED TOWNHOUSE DWELLING UNITS 25 PSF 86 NO DID2 Moderate 18" Moderate 26 NO 12123171, 176 50.6 <br /> 1ST FL 911610-9 <br /> - <br /> CONDITIONED CONSTRUCTION TYPE: TYPE VB <br /> 96 SF OCCUPANCY CLASSIFICATIONS: TOWNHOUSE <br /> FIRE SPRINKLER: YES,NFPA13d GENERAL NOTES: DRAWING INDEX: <br /> 1.Construction shall conform to the 2018 edition of the International Residential Code <br /> SITE DATA: and all applicable regulations adopted by the authority having jurisdiction. SHEET SHEET CONTENTS W <br /> 2.Construction documents for this work have been prepared in accordance with <br /> UNIT B -END UNIT PROJECT ADDRESS: 100TH ST SW AND 18TH AVE W,EVERETT,WA 98204 generally accepted architectural and engineering practice to meet minimum J <br /> requirements of the 2018 edition of the IRC. A01 PROJECT DATA O <br /> A02 CODE COMPLIANCE J <br /> PARCEL TAX I.D.: 00480600102000,00480600102104 3.In the event of conflict between pertinent codes and regulations and referenced A03b WSEC ENERGY ANALYSIS'UNIT PLAN B _ <br /> standards of these drawings and specifications,the more stringent provisions shall MOD' <br /> 2ND FL- <br /> LEGAL DESCRIPTION: SEE SHEET A04 govern. A0 5 ARCHITECTURAL SITE PLAN <br /> CONDITIONED n( <br /> A0 1ST FLOOR PLAN �•! <br /> 3RD FL- 4.Contractor shall be responsible for all materials,construction methods, <br /> UNIT B MOD CONDITIONED ZONING: UR3(URBAN RESIDENTIAL 3),MF(MULTFAMILY-COMPREHENSIVE PLAN) craftsmanship,procedures and conditions(including safety). A07 2ND FLOOR PLAN <br /> 628 SF � W <br /> CONDITIONED A09 3RD FLOOR PLAN C3 <br /> Name Area SITE AREA: GROSS DEVELOPABLE: 51,598.87 SQ.FT.(APPROXIMATELY 1.18 ACRES) At1 ROOF PLAN Z <br /> 682 SF 5.Contractor shall verify all existing conditions,requirements,notes,and dimensions <br /> NET DEVELOPABLE: 51,99.87 SQ.FT.(APPROXIMATELY 1.18 ACRES) N <br /> shown on drawings or noted in specifications.Any variances within drawings and Al2 EXTERIOR ELEVATIONS > � <br /> 1ST FL-CONDITIONED 89 SF specifications,or with conditions encountered at site,shall be reported in writing to A15 REFLECTED CEILING PLAN O W (,) <br /> ONDITI D SETBACKS: FRONT(STREETS)&REAR LOT LINES:20' the architect before commencement of an work affected h such variance. A16 BUILDING E BUILDING SECTIONS G LL <br /> 2ND FL-CONDITIONED 628 SF y y <br /> r SIDE(INTERIOR):5',SIDE(STREET):10' T <br /> $9,��.. 3RD FL-CONDITIONED 882 SF A77 INTERIOR ELEVATIONS <br /> r fi.Contractor shall rigidly adhere to all laws,codes,and ordinances,which apply to this Q <br /> 1400 SF work.Contractor shall notify and receive written clarification from the architect of any A78 WEATHER BARRIER Z U <br /> MAXA19 AIR BARRIER <br /> .ALLOWABLE BUILDING HEIGHT: 50 FT variations between contract documents and goveming regulations. A20 FIRE RESISTANT CONSTRUCTION /Wy tL <br /> MAX.LOT COVERAGE: N/A 7.The contractor shall make no structural changes without written approval of the A21 FIRE RESISTANT CONSTRUCTION W <br /> (TOTAL BLOG FOOTPRINTS) architect or engineer of record. A22 CONSTRUCTION DETIALS <br /> PARKING REQUIRED: 1.5 STALLS PER TWO BR UNIT B.The architect assumes no responsibility for construction conformance,means, A23 CLADDING DETAILS <br /> 2.0 STALLS PER THREE BR UNIT methods,techniques or procedures of on-site work relating to the construction plans. <br /> _(11 TWO BR.UNITS X 1.5 SPACES)+(12 THREE BR.UNITS X 2 SPACES)=41 SPACES <br /> 9.All manufactured materials,components,fasteners,assemblers,etc.,shall he STRUCTURAL <br /> a PARKING.PROVIDED: 73 SPACES handled and installed in accordance with manufacturer's instructions and provisions of Sol GENERAL STRUCTURAL NOTES <br /> w m (2 PER UNIT,17 OFF-STREET GUEST SPACES,10 ON-STREET GUEST SPACES) applicable industry standards.Where specific manufactured products are called for, 802 FIRST FLOOR FRAMING PLAN <br /> a 1ST FL- generic equals that meet applicable standards and specifications may be used. S03 SECOND FLOOR FRAMING PLAN <br /> SO4 THIRD FLOOR FRAMING PLAN <br /> UNCONDITIONED 10.All materials used to be selected and installed in accordance with state,federal, S05 ROOF FRAMING PLAN <br /> TOTAL BUILDING AREA-BUILOING E national and local codes and installed in accordance with manufacturers recommended so <br /> 6 DETAILS <br /> 538 SF installation procedures. <br /> .E S07 DETAILS ' <br /> m Name Area DEFERRED SUBMITTALS: 11.Construction loads shall not overload structure nor shall they be in excess of design S08 DETAILS <br /> 1ST FL-CONDITIONED 280 SF loadings indicated herein. S09 DETAILS I <br /> 1ST FL-UNCONDITIONED 1554 SF THE GENERAL CONTRACTOR(GC)SHALL BE RESPONSIBLE FOR O N <br /> VERIFYING EXISTING FIELD CONDITIONS AND COORDINATING ALL 12.Drewings and specifications are intended to provide the basis for the proper <br /> E 2ND FL-CONDITIONED 1659 SF DEFERRED SUBMITTALS.THE GC'S SUBCONTRACTOR(S)SHALL BE completion of the Project suitable for the intended use of the Owner. , <br /> 0 3RD FL CONDITIONED 2048 SF RESPONSIBLE FOR VERIFYING COMPLIANCE WITH LOCAL AUTHORITIES <br /> s Grand total 5741 SF AND ALL CURRENT CODES,REGULATIONS&REQUIREMENTS. 13.Items not expressly set forth but which are reasonably implied or necessary for the a <br /> Q ELECTRICAL proper performance of this work shall be included. <br /> PROJECT TEAM. FIRE SPRINKLER 1. THE ELECTRICAL WORK FOR THE PROJECT SHALL BE <br /> PERFORMED AS DESIGN-BUILD.THE GC SHALL SUBMIT WITH 14.Inspect substrates and report unsatisfactory g. p Q <br /> 1. THE FIRE SPRINKLER FOR THE PROJECT SHALL BE DESIGNED p p rt unsatisfacto conditions in writing.Do not proceed <br /> THE BID A PROPOSED ELECTRICAL DRAWING THAT until unsatisfactoryconditions have been corrected. <br /> AS DESIGN-BUILD.THE GC SHALL SUBMIT WITH THE BID A PROPOSED COORDINATES WITH THE ARCHITECTURAL DRAWINGS& <br /> FIRE SPRINKLER DRAWING THAT COORDINATES WITH THE COMPLIES WITH ALL CODES,REGULATIONS&REQUIREMENTS. Additional Permits Are Required vJoe No.: <br /> OWNER CIVIL ENGINEER LANDSCAPE ARCHITECT ARCHITECTURAL DRAWINGS&COMPLIES WITH ALL CODES, 15.Unless noted otherwise,all horizontal dimensions are framing to framing of lumber Q <br /> 2. THE GC'S ELECTRICAL SUBCONTRACTOR WILL BE <br /> - PACIFIC RIDGE HOMES CPH CONSULTANTS CPH CONSULTANTS REGULATIONS&REQUIREMENTS. or to face of concrete.All vertical dimensions are to top of structural floor sheathing or For This Project TO Include: zzzos <br /> RESPONSIBLE FOR APPLYING&SECURING ALL NECESSARY <br /> 17921 BOTHELL EVERETT HWY 11321-B NE 120TH STREET 11321-B NE 120TH STREET 2. FIRE SPRINKLERS ARE REQUIRED TO RE UNDER A SEPARATE roof sheathing. <br /> ELECTRICAL PERMITS. <br /> SUITE 100 KIRKLAN,WA 98034 KIRKLAN,WA 98034 PERMIT-THE GC'S FIRE SPRINKLER SUBCONTRACTOR(S)WILL BE ®Plumbing Sprinkler PLOT DATE <br /> BOTHELL,WA 98012 PHONE:(425)285-2390 PHONE:(425)285-2390 RESPONSIBLE FOR APPLYING&SECURING ALL NECESSARY PERMITS. 18.Do not scale drawings.Use dimensions as indicated for all locations. <br /> PHONE:(425)438-8444 CONTACT:MATT HOUGH,PE CONTACT:DAVEANDREWS,LA ADDITIONAL DEFERRED SUBMITTALS: ®Mechanical =Fire Alarm 8/4/202310:44:18 AM <br /> CONTACT:SCOTT BORGESON EMAIL:MATT@CPHCONSULTANTS.COM EMAIL:DAVE@CPHCONSULTANTS.COM MECHANICAL&PLUMBING 17.All construction documents are complimentary,and what is called for by any will be <br /> m 1. THE MECHANICAL&PLUMBING WORK FOR THE PROJECT SHALL -ROOF TRUSS SHOP DRAWINGS&ENGINEERING binding as if called for by all.any work shown or referred to on any construction Electrical - <br /> BE PERFORMED AS DESIGN-BUILD.THE GC SHALL SUBMIT WITH documents shall be provided as though on all related documents.The construction L DATE: 06/08/2023 <br /> ARCHITECT STRUCTURAL ENGINEER ENVELOPE CONSULTANT THE BID A PROPOSED HVAC&PLUMBING DRAWING THAT documents are provided to illustrate the design and general type of construction, <br /> SPECIAL INSPECTIONS: SCALE: As indicated <br /> COORDINATES WITH THE ARCHITECTURAL DRAWINGS& reap nal and workmanship throughout.the general contractor,in assuming <br /> WATTENBARGER ARCHITECTURE,INC. BTL ENGINEERING,INC. CONSTRUCTION CONSULTANTS OF WA. COMPLIES WITH ALL CODES,REGULATIONS 8 REQUIREMENTS. responsibilities for the work indicated,shall comply with the spirit as well as the letter in a DRAWN: MB <br /> 2100112TH AVENUE NORTHEAST 19011 WOODINVILLE RD.NE,SUITE 100 40 LAKE BELLEVUE,SUITE 100 2, THE GC'S MECHANICAL SUBCONTRACTOR WILL BE which they were written. <br /> SUITE 100 WOODINVILLE,WA.98072 BELLEVUE,WA 98005 °CHCKD: TM <br /> BELLEVUE,WA.98004 PHONE:(425)814-8448 PHONE: (425)709-6100 RESPONSIBLE FOR APPLYING&SECURING ALL NECESSARY SPECIAL INSPECTIONS SHALL BE REQUIRED AS ESTABLISHED BY _ <br /> o MECHANICAL PERMITS. THE AUTHORITY HAVING JURISDICTION AND PER STRUCTURAL 18.Deviations from these drawings which are not performed with prior written consent <br /> PHONE:(425)453-0606 CONTACT:RYAN HARTMAN CONTACT:DIANE GLENN <br /> CONTACT:TRAVIS MCDANOLD A.IA 3. ALL MECHANICAL&PLUMBING IS REQUIRED TO BE UNDER A ENGINEERING from the architect are solely at the contractors risk and he shall accept fully liability for BLDG. SHEET NO.: <br /> SEPARATE PERMIT THEGC-S PLUMBING SUBCONTRACTOR WILL BE same. <br /> RESPONSIBLE FOR APPLYING&SECURING ALL NECESSARY PLUMBING - /L O <br /> PERMITS. /(,S <br /> U <br />