Laserfiche WebLink
OPTIONAL <br /> External Secondary <br /> Line Reactor RhymeBus R M 6 G 1 V F D <br /> 460v/230v L1 - - - - - - - - - MODBUS <br /> POWER SUPPLY <br /> L3 — — — — — — OPTIONAL <br /> CURRENT TRANSFORMER <br /> rn WHITE 8_ S11D <br /> OPTIONAL ED m ® G) <br /> GN <br /> �� <br /> A o T <br /> + SHIELD[g] External Secondary <br /> CURRENT TRANSFORMER " ® — <br /> p � Line Reactor <br /> (n WHITE 1` SI DIGITAL ANALOG <br /> rn— y J L <br /> z L7 r--II GND r-- — <br /> O ® Z��—— 460v/230v ——J <br /> v SHIELD[B] POWER ---------------- — <br /> ra ® SUPPLY <br /> DIGITAL ANALOG <br /> 460v/230v <br /> POWER _ <br /> SUPPLY ,� I <br /> CURRENT TRANSFORMER <br /> m ® �s_ WHITE SI I External <br /> GND I DC Line Reactor <br /> II ° ® + SHIELDo-�--IC I <br /> II a ® [T I <br /> REMOVE <br /> DIGITAL ANALOG I I P+ R FROM <br /> O P1External <br /> IL---------J I I WHEN INSTALLING <br /> Secondary EXTERNAL DC LINE REACTOR (Optional) <br /> CURRENT TRANSFORMER I I Line Reactor O O O CooIBLUE and NaLA <br /> I PR P+ P1 + N- — L1 COMPRESSOR <br /> m ® �i WHITE GNUD <br /> I O R/L1 RM6G 1 u/T1 0 — l —— MOTOR <br /> ——L2 <br /> —� — <br /> ® Z --IL— S/L V/T2 2 -- <br /> DIGITAL ANALOG <br /> L-- ——————- OPE PEO <br /> CHASSIS <br /> GROUND <br /> DX+ WHITE - <br /> SWITCH ON <br /> — — — — — PLC SET TO"ON" DX- <br /> BLACK - - V_ <br /> COMP I-L K <br /> RELAY — — — — — - — — — — — — — X1 DSW1 e DX+ II <br /> M-1 z <br /> II <br /> X2 O O JP2 1 DX- I <br /> X3 SOURCE JUMPER FIG <br /> X4 ON"SINK" I <br /> I [M JP9 II <br /> X5 SINK ` FM_P <br /> X6 O ® O COM I I <br /> X7 <br /> I <br /> I <br /> X8 AM+ <br /> I <br /> L— — — — — — — — COM FM+ II <br /> M- � I <br /> I I <br /> Ta2 I <br /> P15 SETTTCH TO"I" Tb2 I I <br /> N12 SWITCH 2 <br /> F_ 12 VDC+ SET TO WIN" <br /> SEE PAGE� TC2 <br /> r — —12 VDC- P12 SW1 SW2 I I <br /> Vint I VIN Tat <br /> Tb1 I <br /> Vint e e I <br /> O ®® O Tc1 I I <br /> lin <br /> V P/NTC <br /> tos GND <br /> 07 <br /> �l• \� <br /> Program Select s ,� s N RO ADDRESS=0 Y1 I <br /> 18=RhymeBus Termination <br /> RM6G1 �QN <br /> Note:Program will be ;q p`' 9 K SI ADDRESS=3 <br /> loaded on reset or 9 ®®® ®®® Y2 I I <br /> power-up. <br /> O + -GND + -GND O <br /> MODBus f Mcsuo H1 O CME I I <br /> g JP8 <br /> U U <br /> H2 o I I <br /> cl �= HC DM- <br /> Cg:6] DM+ <br /> ISHIELD I <br /> Communications from MCS-SI16-AO4#2 <br /> (shield grounded at this end only) I I <br /> Communications to MCS-SI16-AO4#4 <br /> (shield not grounded at this end)IL I I <br /> I <br /> I <br /> - - J <br /> Factory wired: <br /> Field wired: <br /> CSCRORhymeBus RM6G1 VFD <br /> NTRMOL Typical Wiring <br /> YSTEMS <br /> SO# 000000 Micro Controls Systems <br /> Unit Type RhymeBus <br /> Drawing # 000000-01 <br /> Revision la 12/28/2022 <br /> CAD Tech I LM Page 2 of 2 <br />