My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1321 COLBY AVE BASE FILE 2024-11-13
>
Address Records
>
COLBY AVE
>
1321
>
BASE FILE
>
1321 COLBY AVE BASE FILE 2024-11-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2024 8:32:04 AM
Creation date
11/13/2024 8:20:21 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
1321
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
K ENGINEERS INC. <br /> 208 Third Street <br /> Lyndon, WA. 98264 W <br /> Bus. 360 354-4757 = <br /> FAX 360 354-6794 <br /> EXISTING PANEL FGCH2 EXISTING PANEL FGCL9 yj <br /> VOLTAGE: 480Y/277V,3 PH,4 W FEED ER/BRANCHMA ERRANCH CIRCUIT DEVICES'. ELECTRICAL LOAD CONN.LOAD(VA) DEMAND DEMAND VOLTAGE: 208Y/12OV,3 PH,4 W FEEDER/BRANCH CIRCUIT DEVICES: ELECTRICAL LOAD CONN.LOAD(VA) DEMAND DEND = <br /> TYPE: PANELBOARD BOLT-ON CIRCUIT BREAKERS CALCULATION EXIST I NEW I TOTAL FACTOR LOAD VA TYPE'. PANELBOARD BOLT-ON CIRCUIT BREAKERS CALCULATION EXIST. NEW TOTAL FACTOR LOAD(VA) <br /> ENCLOSURE: NEMA1 FULL AIC RATING: 14,000A Lighting 23421.1 178.0 23600.0 1.25 29500.0 ENCLOSURE. NEMA1 FULL AID RATING: 10000A Lighting 23400 00 23400 125 29250 W <br /> MOUNTING: SURFACE SERIES AIC RATING: 65,000A Gen.Purpose Outlets(Fimt 10 KVA) 10000.0 0.0 10000.0 1.00 10000.0 MOUNTING'. SURFACE SERIES AID RATING: 22,000A Gen.Purpose Outlets(First 10 KVA) 10000.0 0.0 10000.0 1.00 10000.0 <br /> Gen.Purpose Outlets(Remainder) 49580.0 180.0 49760.0 0.50 24880.0 Gen.Purpose Dutlets(Remainder) 24560.1 180.0 24740.0 0.50 12370.0 uj <br /> BUSSING:MANUFACTURER'SSTANDAR SPECIAL PROVISIONS: Special Purpose Carets 509400 00 509400 100 50940.0 BUSSING:MANUFACTURER'S STANDAR SPECIAL PROVISIONS: Special Purpose Callers 24310.0 0.0 24310.0 1.00 24310.0 =U <br /> CONTINUOUS RATING:600 A Mechanical Equipment 7980.0 0.0 7980.0 1.00 7980.0 CONTINUOUS RATING.225 A Mechanical Equipment 0.0 0.0 0.0 1.00 0.0 V <br /> FULLAIC RATING'. 65,000A MASTER NAMEPLATE Kitchen Equipment&Appliances 0.0 0.0 0.0 1.00 0.0 FULLAICRATING'. 22,000A MASTER NAMEPLATE Kitcten Eq uipment&Appliances 0.0 0.0 0.0 1.00 O.o y-+ <br /> SERIES AIC RATING. NONE Miscellaneous 75000.0 31250.0 106250.0 1.00 106250.0 SERIESAICRATING: NONE Miscellaneous 00 00 00 1D0 00 m L <br /> GROUND BAR 25%Largest Motor 0.0 GROUNDBAR 25%Largest Motor 00 0 <br /> MAIN: LUGS ONLY MAIN'. LUGS ONLY m Q <br /> LOCATION: TOP TOTAL LOAD 2169220 316080 2485300 2295500 LOCATION: BOTTOM PROVIDE HANDLE TIES FOR ALL TOTAL LOAD 61210.0 160.0 61390.0 49605.0 <br /> TOTALAMPS 260.9 38.0 298.9 276.1 MULTFWIRE BRANCH CIRCUITS TOTAL AMPS 1699 05 1704 1377 <br /> CONN. FEEDER/BRANCH CIRCUIT BKR CKT BUS CKT BKR FEEDER]RANCH CIRCUIT CONN. CONN. FEEDER/BRANCH CIRCUIT BKR CKT BUS CKT BKR FEEDERIBRANCH CIRCUIT CONN. <br /> LOAD(VA) DESCRIPTION O1E AMP/P NO (PHASE) NO AMP/P DESCRIPTION .e LOAD(VA) LOAD A DESCRIPTION a AMP/P NO PHASE NO AMPIP DESCRIPTION e LOAD VA <br /> 293 3 <br /> MAIN LUGS SUB-FEED LUGS PANEL FlCL10 11293.3 <br /> 11293.3 <br /> 2120.0 Ughtirg LEVEL G SOUTH EXTERIOR 2011 1 A 2 20/1 Lighting LEVEL G SOUTH 4030.0 700.0 Equip PSVC HWKRM-CRSHCART 2011 1 A 2 20/1 Equip TRAUMA RM C0194-CRASH CART 700.0 <br /> 4090.0 Li hti LEVELG SOUTH 1 20/1 3 B 4 20/1 Li h[in SW LEVELGSOUTH EBRL 3930.0 1080.0 Equip PSVCH WKRM-E.WALL 2011 3 B 4 20/1 <Multi>TRAUMA RM CO194-WIREMLD,COMP 900.0 <br /> 2000.0 Li hti LEVELG SOUTH 20/1 5 C 6 20/1 SPARE 0.0 1080.0 Equip PSYCH WKRM-W.WALL 20/1 5 C 6 2011 SPARE 0.0 <br /> 1330.0 Meoh FCU-G03 20/3 7 A 8 201 Meoh FCU-G04 1330.o 10800 E ui SW CRGVR STN 20/1 7 A 8 2011 Pat Room TRAUMA RM C0194-BOOM 7200 <br /> 13300 9 B 10 13300 750.0 Equip SWCRGVRSTN-MEDS-REF 2011 9 B 10 20/1 Pat.Room TRAUMA RM C0194-BOOM 720.0 <br /> 1330.0 11 C 12 1330.0 900.0 Equip SWCRGVRSTN-MEDS-PYXIS 20/1 11 C 12 20/1 <M.Iti,TRAUMA RM C0194-BOOM 870.0 2727 Oakes Ave. <br /> 10416.]X-RAY-RAD ROOM#1 CO203 (1) 80/3 13 A 14 1250 X-Ray CT EQUIP RM F0265 25000.0 180.0 E ui SWCRGVR STN-SOIL HLO 20/1 13 A 14 2011 <Multi>TRAUMA RM C0194-BOOM,LIGHT 330.0 Suite 100 <br /> 10416.] (NEXTg 25%DEMAND) 15 B 16 (LARGESTQ 50%DEMAND) 25000.0 360.0 Rece tsar ELEC.RM 20/1 15 B 16 20/1 E ui TRAUMARM C0195-CRASHCART 700S Everett,WA 98201 <br /> 104157 I17 C 18 1 250000 700.0 Equi IFSW C RGVR STN C LN SPLY-CRSHCART 2011 17 C 18 20/1 <Multi>TRA UMA RM CO 195-WIREM LID,COMP 900.0 <br /> 0.0 SPACE 19 A 20 SPACE 0.0 900.0<M.1ti>DECON SHWR.W.BAD RM. (1) 2011 19 A 20 20/1 SPARE 0.0 <br /> 0.0 21 B 22 0.0 7200 E u1 RADWRKRMWAl 20/1 21 B 22 2011 Pat.Room TRAUMA RMC0195-BOOM 7200 REVISIONS <br /> 0.0 23 C 24 0.0 720.0<Multi>RAD WRKRM,E.RAD RM 2011 23 C 24 20/1 Pat.Room TRAUMA RM C0195-BOOM 720.0 <br /> 0.0 SPACE 25 A 26 SPACE 0.0 850.0 Equip S.CNTRL HUG COPY/FAX/PRIM 20/1 25 A 26 2011 <Multi>TRAUMA RM C0195-BOOM 870.0 <br /> 0.0 27 B 28 0.0 960.0 Equip S.CNTRL HUG-MD WKSTNS 20/1 27 B 28 2011 <Multi>TRAUMA RM C0195-BOOM,LIGHT 330.0 <br /> 00 29 C 30 F. 18000 E ui STAFF LOUNGE REF 20/1 29 C 30 20/1 E ui LCP-GS 1000 <br /> 38536.7 PANELFGCLB 350/3 31 A 32 SPACE 0.0 500.0 Equip RAD WKRM-XRAY VIEW BOX 2011 31 A M42 <br /> 20/1 Equip TRAUMARMC0194-XRAYVIEWBOX 500.0 <br /> 39796.] 33 B 34 0.0 850.0 E ui SW CGG COPY/FAX/PRINT 20/1 33 B 2011 E ui TRAUMA RM C0195-XRAYVIEW BOX 500.0 <br /> 391957 35 C 36 00 1800.0 E ui S.CMRL HUC-NRSH-ICE MACH 20/1 35 C20/1 SPARE 0.0 <br /> 0.0 SPACE 37 A 38 SPACE 0.0 1000.0 E ui ED TRTMT CORRIDOR NW AUTODOOR 20/1 37 A 20/1 SPARE 0.0 <br /> 0.0 39 B 40 0.0 1000.0 Equip ED TRTMT CORRIDOR SWAUTODOOR 2011 39 B 2011 SPARE 0.0 <br /> 0.0 41 C 42 0.0 00 SPARE 20/1 41 C2011 SPARE 0.0 <br /> NOTES: NET CONNECTED LOAD CHANGE: REMOVED(VA) ADDED(VA) MAIN LUGS <br /> (1) MODIFIED EXISTING CIRCUIT ON EXISTING CIRCUIT BREAKER. LIGHTING 348.0 178.0 <br /> (2) ALL OTHER CIRCUITS ARE EXISTING TO REMAIN. OUTLETS 180.0 <br /> MECHANICAL 0.0 NOTES: <br /> MISCELLANEOUS 337500 312500 (1) MODIFIED EXISTING CIRCUIT ON EXISTING CIRCUIT BREAKER. R. DI <br /> TOTAL 34098.0 31608.0 (2) ALL OTHER CIRCUITS ARE EXISTING TO REMAIN. ,v1�pF WAS A� <br /> NETCHANGE -24900 V R C I. <br /> �N <br /> 3 �a+ <br /> EXISTING TRANSFORMER FGCLB <br /> KVA: 225 PHASE: 3 TYPE. DRY ELECTRICAL LOAD CONN.LOAD A DEMAND DEMANDENCLOSU N7"9,�.c,,�µ0on\�' <br /> Is <br /> PRIMARY: 480 DELTA MOUNTING NEMAl FLOOR LightingALCULATION EXIST NEW <br /> NEW00 T74AOL0 FACTOS LO 9D8'S) owes ONAL <br /> SECONDARY:20BY1120 Gen.Puose Outlets(First 10 KVA) 10000.0 0.0 10000.0 1.0 Fare... 0 10000.0 <br /> TAPS. 2Q2.5%FCAN WINDINGS. MANUFACTURER'S Gen.Purpose Outlets(Remainder) 49580.0 180.0 49760.0 0.50 24880.0 <br /> Special <br /> 4a 2.5%FCBN STANDARD Purp ose Oarets 50940.0 0.0 50940.0 1.00 50940.0 <br /> Mechanical Equipment 0.0 00 00 100 0.0 <br /> COOLING: CA SPECIAL PROVISIONS: Kitchen Equipment&Appliances 0.0 0.0 0.0 1.00 0.0 <br /> K-13 RATED Miscellaneous 0.0 0.0 0.0 1.00 0.0 <br /> INSULATION'. CLASS 220 DEPT.OF ENERGVCOMPLIANT 25%Largest Motor 0.0 ^ <br /> ENERGYSTAR NAMEPLATE <br /> cu <br /> TEMP.RISE: 150C(40C AMBIENT) MASTER NAMEPLATE TOTAL LOAD 117950.0 180.0 118143 10 95114.4 <br /> TOT AL AMPS(PRIMARY) 141.9 0.2 142.1 114.4 <br /> TOTAL AMPS(SECONDARY) 327.4 0.5 327.9 264.0 <br /> I <br /> EXISTING PANEL FGCL8 \/ <br /> VOLTAGE: 20BY/12OV,3 PH,4 W FEEDER/BRANCH CIRCUIT DEVICES'. ELECTRICAL LOAD CONN.LOAD VA) DEMAND DEMAND /\ <br /> TYPE: PANELBOARD BOLT-ON CIRCUIT BREAKERS CALCULATION EXIST. NEW TOTAL FACTOR LOAD(VA) <br /> ENCLOSURE: NEMA1 FULL AIC RATING: 10000A Lighting 74300 00 74300 125 92875 <br /> MOUNTING: SURFACE SERIES AIC RATING: NONE Gen.Purpose Outlets(First 10 KVA) 10000.0 0.0 10000.0 1.00 10.00.. <br /> Gen.Purpose Outlets(Remainder) 49580.0 180.0 49760.0 0.50 24880.0 <br /> BUSSING:MANUFACTURER'S STANDAR SPECIAL PROVISIONS: Special Purpose Carols 50940.0 0.0 50940.0 1.00 50940.0 <br /> CONTINUOUS RATING.800 A Mechanical Equipment 0.0 0.0 0.0 1.00 0.0 EXISTING DOOR OPERATOR X-RAY CIRCUIT BREAKER <br /> FULLAIC RATING'. 10,000A MASTER NAMEPLATE Kitchen Equipment&Appliances 0.0 0.0 0.0 1.00 O.o EX KaXL2-2 (REMOVE EXISTING GIRCUII BREAKER <br /> S ERIES AIC RATING: NONE Miscellaneous 00 00 00 100 0.0 1N$TAL Eii1PoJI6HEB-61 <br /> GROUND BAR 25%Largest Motor 0.0 <br /> MAIN: CIRCUIT BREAKER BRAKE <br /> CONTINUOUS RATING:800 A SUITABLE FOR USE AS SERVICE EX EX CONNEC EXISTI WIRIN. <br /> FULLAICRATING. 10,000A ENTRANCE EQUIPMENT <br /> SERIES AIC RATING: NONE TOTAL LOAD 117950.0 180.0 118130.0 95107.5 EX ,21,23 EXISTING I'0' T(3"3 AUK <br /> LOCATION: BOTTOM TOTAL AMPS 32].4 0.5 327.9 264.0 L 3 AWG G ) Q <br /> X <br /> CONN. FEEDER/B RANCH CIRCUIT BKR CKT BUS CKT BKR FEEDER/BRANCH CIRCUIF CONN. EX FE <br /> LOAD A DESCRIPTION AMP/P NO PHASE NO AMP/P DESCRIPTION rE LOAD(VA LI II <br /> 0.0 1 A 2 30/3 NSS 0.0 D. <br /> 0.0 3 B 4 0.0 ^' <br /> 00 5 C 6 00 FGCL919 W <br /> 189133 PANELFGCL12 40013 7 A 8 4000 PANELFGCL9 19M39 <br /> 18913.3 9 B 10 1 20883.3 U m f <br /> 18913.3 11 C 12 20883.3 <br /> 0 0 13 A 14 0 0 FGGLS- o <br /> 0.0 15 B 16 0.0 EX w`�ror� <br /> 0.0 17 C 18 0.0 W <br /> ' <br /> 0.0 19 A 20 0.0 FGNL1011 O 0) <br /> 0.0 21 B 22 0.0 Q <br /> 0.0 23 C 24 0.0 <br /> 0.0 25 A 26 0 o EX <br /> 0.0 27 B 28 0.0 <br /> 0.0 29 C 30 0.0 \ O - <br /> at <br /> MAIN CIRCUIT BREAKER <br /> O � " m <br /> X ^^L /yam C4 m <br /> U LiEX 1..� L.L r W <br /> FGCL9-19 <br /> RE-CONNECT NEW EQUIPMENT TO '-' " 2297 <br /> EXISTING CIRCUIT. <br /> KL <br /> El a, BD <br /> PERMIT SET <br /> 5-11-24 <br /> ELECTRICAL - <br /> POWER PLAN & <br /> SCHEDULES <br /> N <br /> ELECTRICAL - POWER PLAN 1/4' E 2.1 <br /> 12; a••r-o• 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.