NORTH <br /> 0 verizon� <br /> W,c.,wnats Below. <br /> Call before you dig <br /> PROJECT: <br /> 2220 CHESTNUT ST 2216 CHESTNUT ST LEGEND: 1703MNTR.001 ROW EVT 2390 <br /> 2232 CHESTNUT ST BORE/MISSILE BORE IERM,TT,N—T,TY <br /> OPEN TRENCH CITY OF EVERETT <br /> SIDEWALK <br /> C ST <br /> E.O.P EDGE OF PAVEMENT 3200 20TH <br /> INSTALL 207 LF OF EVERETT,WA <br /> 2228 CHESTNUT ST 2224 CHESTNUT ST B.O.c BACK OF CURB <br /> 1 - 2" HDPE CONDUIT <br /> R.O.W. RIGHT OF WAY <br /> (BORE) C.L.--- STREET CENTERLINE <br /> R.O.W. im <br /> R.O.W. • POTHOLE LOCATION Ov — Z — <br /> 0+00 1+00 2+00 � o w ° <br /> v ^ , < <br /> 0' 10, 20' 40' > W = Q <br /> - O Lu z <br /> 8,0 C. Z Z Lm <br /> SEE PERMIT PACKAGE: <br /> B.O.C. N ov = z <br /> O <br /> 1703MNTR.001_ROW_EVT_2389 � z � Z a p^ Z <br /> w_ a <br /> o V) o of <br /> of <br /> Lu <br /> w D <br /> u O <br /> CHESTNUT ST a <br /> — <br /> 0 <br /> + <br /> FORESITE <br /> 6 G B.O.C. < gPOLln <br /> S)00 Ee Group,Inc. w I wew.887.6 64 <br /> 3000 E Ceaer Chavez St. a 1334.66].6064 <br /> Sure 400 f334.66].6024 <br /> Ld =ie,TX]6]02 <br /> J <br /> U <br /> Q <br /> R.O.W. R.O.W. <br /> 0 <br /> ENGINEER: AB <br /> DRAWN BY: Jaw <br /> REVISIONS <br /> IATF DESCRIPTION INITIAL <br /> NOTE TO CONTRACTOR: <br /> ANY BOREPITS DUG NEXT TO DRIPLINE OF AN EXISTING TREE <br /> TO BE DUGGED USING HYDRO VACCUUM EXCAVATION. <br /> CAUTION" <br /> ANY DISTURBANCE TO INFRASTRUCTURE WITHIN 15 FEET OF <br /> ADA RAMP WILL REQUIRE ENTIRE RAMP TO BE REPAIRED IN <br /> ACCORDANCE WITH ALL REQUIRED ADA STANDARDS AND <br /> 2231 CHESTNUT ST 2227 CHESTNUT ST 2225 CHESTNUT ST SPECIFICATIONS. <br /> ALL TELECOM UTILITY LOCATIONS ON PRINT ARE BASED ON <br /> FIELD SURVEY AND OBSERVATIONS.LOCATIONS MAY NOT BE <br /> ACCURATE OR COMPLETE. EXCEPT CAS MAY BE OTHERWISE PROVIDED BY CONTRACT <br /> THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THE <br /> CONTRACTOR TO PLACE UTILITY WITH A MINIMUM OF 36 FIR PERTY OF MCI COMMUNICATIONS SERVICES,INC..BOT <br /> E <br /> INCHES OF COVER WHEN UNOBSTRUCTED.CONTRACTOR TO REING ISSUED IN STRICT CONFIDENCE AND SHALL NOT B <br /> PRODUCED, COPIED, OR USED FOR ANY PURPOSE <br /> MAINTAIN 24 INCHES OF SEPARATION FROM OTHER UTILITIES. WITHOUT SPECIFIC WRITTEN PERMISSION. <br /> DEPTH TO BE ADJUSTED ACCORDINGLY. <br /> UTILITY LOCATIONS SHOWN ON THIS PLAN ARE BASED ON SCALE <br /> DOCUMENT RESEARCH AND FIELD EVALUATION. THE <br /> INFORMATION MAY NOT BE ACCURATE OR COMPLETE.IT IS HORIZONTAL: 1"=20' <br /> THE CONTRACTOR'S RESPONSABILITY TO PHYSICALLY <br /> LOCATE AND VERIFY LOCATION AND DEPTH OF ALL UTILITIES VERTICAL: N/A <br /> WITHIN CONSTRUCTION PATH. <br /> ALL INSTALLATIONS MUST COMPLY WITH MINIMUM <br /> HORIZONTAL AND VERTICAL CLEARANCES FROM UTILITIES. <br /> SHEET: C-01 <br />