My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1610 106TH PL SW A, B 2024-12-09
>
Address Records
>
106TH PL SW
>
1610
>
1610 106TH PL SW A, B 2024-12-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/9/2024 1:54:04 PM
Creation date
11/15/2024 7:07:50 AM
Metadata
Fields
Template:
Address Document
Street Name
106TH PL SW
Street Number
1610
Unit
A, B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
#B2401-013 i <br />ECEIVE <br />Permit Corrections Response Letter <br />MAR 14 <br />CITY OF EVERETT <br />Permit Services <br />The requested revisions / corrections listed here have been responded to as indicated in the letter below. Please do not hesitate to reach out if you have <br />any further questions. <br />BUILDING: <br />1. IRC 302.3.2 Fire -resistance -rated floor/ceiling and wall assemblies shall extend to and be tight against the exterior wall, and wall assemblies shall <br />extend from the foundation to the underside of the roof sheathing. Please provide a drawing to show the intersection where fire resistance rated <br />wall meets the exterior wall (plan view). <br />See added detail on A8 shed for compliance with IRC 302.32. Note that the party wall detail was also updated per client request to more <br />accurately depict means and methods of construction, detail remains In compliance with IRC 302. <br />2. 1 was not able to find the location of Whole House Ventilation on floor plan. Please show Whole House Ventilation on the floor plan, what CFM, <br />continuous v.s. intermittent, and 1.0 sone max. and etc.. <br />See A4 for whole house ventilation requirements. Fan CFMs, max som. notes shown on floor plan. <br />3. Please provide attic space ventilation calculation per IRC R806.2. The minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The minimum net free ventilation area shall be 1/300 of the vented space provided both of the exception conditions are met. Please show the <br />ventilation strategy on the roof plan accordingly. <br />See A5 for added requirements for venting. <br />4. Per UPC (WAG) 507.13.1 appliances installed in garages, warehouses, or other areas subject to mechanical damage shall be guarded against such <br />damage by being installed behind protective barriers or by being elevated or located out of the normal path of vehicles. Please provide protection <br />accordingly. <br />Notes added to A4. <br />5. Per IRC G2406.2 (303.3) fuel gas appliances (furnace) shall not be located in sleeping rooms,..., storage closets or surgical rooms, or in a space that <br />opens only into such rooms or spaces, except where the installation complies with one of the exceptions. Please check all the exceptions if any of those is <br />applicable for this project. If furnace is not fuel gas, please indicate on the floor plan accordingly. You may also remove the closet door so it is <br />ok to be in laundry room. <br />Furnaces are electric, note added to A4. <br />Thank You, <br />Joe Tracy - Partner / Architect <br />ioe0fieldreport.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.