Laserfiche WebLink
y ' Pipe Hangers <br /> TOLCOTM Fig.200 - "Trimline" Adjustable Band Hanger <br /> TOLCOTM Fig.200F- "Trimline" Adjustable Band Hanger with Felt Lining for Copper Tubing <br /> TOLCOTM Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated <br /> TOLCOTM Fig.200S - "Trimline" Adjustable Band Hanger with Removable Nut(For sizes 1" thru 2") <br /> Size Range: DC)US <br /> Fig. 200 - 1/2" (15mm)thru 8" (200mm) pipe A :11: <br /> Fig. <br /> Overall Height USTED APPROVED <br /> Material: Steel, Pre-Galvanized B <br /> Function: For fire sprinkler and othergeneral piping purposes. Knurled Center of pipe to top of knurled hanger rod nut. <br /> P pp 9P P o <br /> swivel nut design permits hanger adjustment after installation. • <br /> Top of pipe to bottom of hanger rod nut. <br /> Features: <br /> • 1/2" (i5mm)thru 2" (50rnmi sizes have flared edges for ease of F'g' <br /> , ',.--- ,„ 7,05S\ <br /> installation on all pipe types and protects CPVC plastic pipe from ;' t 2oo-t3/4 <br /> ,® 2oa r4 i 0 <br /> abrasion. Captured knurled nut design (flared top) on 1" thru 2" sizes I <br /> keep nut from separating with hanger. Hanger is easily installed <br /> around pipe. % , <br /> • 1/2" (15mm), :/4" (20mm), arid 21/2" (65mm)thru 8" (200mm)) Spring i, / B <br /> tension on nut holds it securely in hanger before. installation. - r-,, =',, <br /> Knurled nut is easily removed. A <br /> • For 1/2" il5mm)and 3/4" ;20mm)sizes with non-captured knurl nuts fi ' , e <br /> order Fig. 200S i� , <br /> Approvals: Underwriters laboratories listed (1/2" (15mm) thru 8" (200mm)) zoo-zt/2toz0a-8 <br /> in the USA(UL) and Canada (cUL)for steel and CPVC plastic pipe and Fig. I! / i,.. <br /> Factory Mutual Engineering Approved (FM) 13/4" (20mm)thru 8" (200mm)). zoo-1 to i;i ii <br /> Conforms to Federal Specifications VVW-H-171 E &A-A-1192A,Type 10 200-2 <br /> and Manufacturers Standardization Society ANSI/MSS SP-69& SP-58, <br /> Type 10. <br /> Maximum Temperature: 650°F i343°C) 41100 <br /> Finish: Pre-Galvanized. Stainless Steel <br /> materials will be supplied with (2) nex nuts <br /> in place of a knurl nut. <br /> Order By: Part number and pipe size <br /> '. / <br /> , ���,�. <br /> ** Note: For metric hanger rod sizes add the <br /> _ saw. . <br /> metric rod size to the figure number. „" <br /> Example 200M8-11/2 or 200M1 0-11/2 Fig.200C Fig.200F Fig.200 Fig.200&Fig.2005 <br /> 200C-11/2 shown 200E-11/2 shown shown with captured nut shown with <br /> 1"thru 2"sizes only non-captured nut <br /> Pipe Size Rod Size A B D Max.Rec.Load Approx.Wt./100 <br /> Part No"* in. (mm) in. mm** in. (rem) in. (mm) in. (mm) lbs. (kN) lbs. (kg) - <br /> 200-1/2 1/2" (15) 3/8'"-16 M8 or M10 31/8" (79.4) 25/8" (66.7) 111/32"(34.1) 400 (1.78) 11 (5.0) <br /> 200-3/4 3/4" (20) 3/8"-16 M8 or M10 31/8" (79.4) 21/2" (63.5) 11/16" (27,0) 400 (1.78) 11 (5.0) <br /> 200-1 1" (25) 3/8"-16 M8 or M10 33/8" (85.7) 25/8" (66.7) 11/8" (28.6) 400 (1.78) 12 (5.5) <br /> 200-11/4 11/4" (32) 3/8"-16 M8 or M10 33/4" (94.0) 27/6" (73.0) 15/32" (29.3) 400 (1.78) 13 (5.9) <br /> 200-11/2 11/2' (40) 3/8"-16 MO or M10 37/8" (98.4) 27/8" (73.0) 13/16" (30.2) 400 (1.78) 14 (6.4) <br /> 200-2 2" (50) 3/8"-16 M8 or M10 41/2" (114.3) 3" (76.3) 13/16" (30.2) 400 (1.78) 15 (6.9) <br /> 200-21/2 21/2" (65) 3/8"-16 M10 55/8" (142.9) 41/8" (104.7) 17/I6" (36.5) 600 (2.67) 27 (12.3) <br /> 200-3 3" (75) 3/8"-16 M10 57/8" (149.1) 4" (101.6) 11/4" (31.7) 600 (2.67) 29 (13.3) <br /> 200-31/2 31/2" (90) 3/8"-16 M10 73/8' (187.3) 51/4" (133.3) 23/16" (55.6) 600 (2.67) 34 (15.6) <br /> 200-4 4" (100) 3/8"-16 M10 73/8" (187.3) 5" (127.0) 13/8" (34.9) 1000 (4.45) 35 (16.0) <br /> 200-5 5" (125) 1/2"-13 M12 91/8" (231.8) 61/4" (158.7) 311/32"(84.9) 1250 (5.56) 66 (30.2) <br /> 200-6 6" (150) 1/2"-13 M12 101/8" (257.2) 63/4" (171.4) 27/32" (56.3) 1250 (5.56) 73 (33.4) <br /> 200-8 8" (200) 1/2'-13 M12 131/8" (333.4) 83/4" (222.2) 37/32 (81.7) 1250 (5.56) 136 (62.3) <br /> All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. <br /> B-Line series Fire Protection Solutions 23 Eaton <br />