Laserfiche WebLink
T 1 <br /> 3/10/2021 https://waenergycodes.com/print_project_summary_form.php?k=aWQ9MTYzOSZmdmk9MTYmY3RpPTMx&print=1 <br /> a <br /> ---,4^ <br /> ENVELOPE COMPLIANCE SUMMARY <br /> 2018 WSEC Compliance Forms for Commercial Buildings including Group R2,R3&R4 over 3 stories and all Rl Administered by:©2021 NEEA,All rights reserved <br /> Project Title UG 64-2018 WSEC For Building Department Use: I Date: Mar 09,2021 <br /> Project Address 911 Sievers Duecy Road <br /> Project&Applicant Everett,WA 98203 <br /> Information Applicant Name Randy Brown <br /> Applicant Phone 206-450-4075 <br /> Applicant Email Randy.Brown@synthesispllc.com <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> General Occupancy All Commercial General Building Use Type Warehouse,Distribution Building Cond.Floor Area 26,066 <br /> Project Cond.Floor Area 0 <br /> Project Scope New Building Space Conditioning Categories Semi-heated Floors Above Grade 1 <br /> Compliance Method Compliance Method 1-General <br /> elope Project Description Industrial,semi-heated building constructed with tilt-up concrete wall panels,plywood roof deck on steel joist and a concrete slab on grade.The roofing system is single ply TPO over rigid <br /> insulation. <br /> Envelope W WR/SRR <br /> Compliance Scope Space Conditioning Category Compliance Method per Category UA Calculation Adjustment Fenestration Alternates Compliance Verification <br /> Scope and <br /> Method New Building Semi-heated Component performance 4.94%/1.09% None selected No alternates selected COMPLIES <br /> Air Barrier Testing Air barrier testing included in project scope Air Barrier Comments <br /> Project Title UG 64-2018 WSEC % ,;, 4,;. , ,,-, °! '��'° + ate,',,,,, ' <br /> Scope& Space Conditioning NEW BUILDING-SEMI-HEATED Compliance Verification COMPLIES <br /> Window-to-wall Ratio 4.94% Skylight-to-roof-ratio 1.09% Vertical Fenestration Alternate No altemates selected <br /> Opaque Envelope Assemblies <br /> Insulation R-Values <br /> Walls-Semi-heated Space Location in Documents Assembly ID Assembly Location Ca%it.v (%Continuous Insulated Wall U-Factor Net Area(SF) <br /> penetration) Furring <br /> Mass wall-Commercial See Sheet A2.1 Tilt up Concrete Wall Panels Yes 0 U-0.104 15,919 <br /> if/Ceiling Location in Documents Assembly ID Assembly Location Cavity Continuous 2nd Layer U-Factor Net Area(SF) <br /> (%penetration) (MB Roof) <br /> Insulation entirely above deck A2.2/A4.3 plywood roof deck on steel joist-Insulation entirely above deck Exterior R-34(<0.04%) U-0.029 26,066 <br /> U-Factor Source:WSEC Appendix A U-Factor Source Description:Table A102.2.6(1) <br /> Slab-on-grade Floors Location in Documents Assembly ID Assembly Location Slab Edge Under Slab F-Factor Perimeter <br /> Length(SF) <br /> Unheated slab A2.1 Slab on grade At grade level R-0 R-0 F-0.73 670 <br /> F-Factor Source Description:Table A106.1 F-Factor Source:WSEC Appendix A <br /> Slab Insulation Method:Uninsulated slab <br /> Fenestration&Opaque Door Assemblies <br /> Insulation R-Values <br /> Opaque Doors Location in Documents Assembly ID Assembly Location Door Insulation U-Factor Rough <br /> Opening(SF) <br /> Swinging see A3.1/A2.1 see A3.I/A2.1 Exterior U-0.37 192 <br /> What percentage of this opaque door is glazing?:50%or less U-Factor Source:Other U-Factor Source <br /> U-Factor Source Description:manufacturer Is this a public entrance door?:Yes <br /> Garage,Sectional A2.I&A3.1 See A2.1&A3.1 Exterior R-16 I I U-0.062 348 <br /> What percentage of this opaque door is glazing?:50%or less U-Factor Source:Other U-Factor Source <br /> U-Factor Source Description:manufacturer <br /> https://waenergycodes.com/print_project_summary_form.php?k=aWQ9MTYzOSZmdmk9MTYmY3RpPTMx&print=1 1/4 ) <br />