My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
815 SIEVERS-DUECY BLVD 2025-05-05
>
Address Records
>
SIEVERS-DUECY BLVD
>
815
>
815 SIEVERS-DUECY BLVD 2025-05-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/5/2025 7:46:45 AM
Creation date
11/19/2024 11:57:43 AM
Metadata
Fields
Template:
Address Document
Street Name
SIEVERS-DUECY BLVD
Street Number
815
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
960
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
\ 1 � <br /> Page 1 of 3 <br /> TECHNICAL DATA SPRINKLER OVERVIEW <br /> The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 <br /> Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com <br /> 1. DESCRIPTION <br /> Viking fire sprinklers consist of a threaded frame with a specific waterway or orifice size and a deflector for distributing water in a <br /> specified pattern A closed or sealed sprinkler refers to a complete assembly, including the thermosensitive operating element An <br /> open sprinkler does not use an operating element and is open at all times The distribution of water is intended to extinguish a fire <br /> or to control its spread <br /> Viking sprinklers are available in several models and styles Refer to specific sprinkler technical data pages for available styles, <br /> finishes, temperature ratings, thread sizes, and nominal K-Factors for the particular model selected <br /> 2. LISTINGS AND APPROVALS <br /> Refer to the Approval Charts on the appropriate sprinkler technical data page(s) and/or n WARNING cancer and Reproductive Harm- <br /> approval agency listings. `'l wwv.'P65Warnings ca gay <br /> 3. TECHNICAL DATA <br /> Pressure Ratings: <br /> Maximum allowable water working pressure is 175 psig (12 Bar) unless rated and specified for high water working pressure [250 <br /> psig (17 2 bar)] <br /> Sprinkler Identification: <br /> Viking sprinklers are identified and marked with the word"Viking", the sprinkler identification number (SIN) consisting of"VK" plus <br /> a three digit number*, the model letter and the year of manufacture <br /> Available Finishes: <br /> Viking sprinklers are available in several decorative finishes Some models are available with corrosion-resistant coatings or are <br /> fabricated from non-corrosive material Refer to the sprinkler technical data page for additional information <br /> Available Temperature Ratings: <br /> Viking sprinklers are available in several temperature ratings that relate to a specific temperature classification Applicable installa- <br /> tion rules mandate the use and limitations of each temperature classification In selecting the appropriate temperature classifica- <br /> tion, the maximum expected ceiling temperature must be known When there is doubt as to the maximum temperature at the <br /> sprinkler location a maximum-reading thermometer should be used to determine the temperature under conditions that would <br /> show the highest readings to be expected In addition, recognized installation rules may require a higher temperature classifica- <br /> tion,depending upon sprinkler location, occupancy classification, commodity classification,storage height, and other hazards In <br /> all cases,the maximum expected ceiling temperature dictates the lowest allowable temperature classification Sprinklers located <br /> immediately adjacent to a heat source may require a higher temperature rating <br /> K-Factors: <br /> Viking sprinklers are available in several orifice sizes with related K-Factors The orifice is a tapered waterway and, therefore, the <br /> K-Factor given is nominal Nominal U S K-Factors are provided in accordance with the 1999 edition of NFPA 13, Section 3-2 3 <br /> Refer to the specific data page for appropriate K-Factor information <br /> Available Styles: <br /> Viking sprinklers are available for installation in several positions as indicated by a stamping on the deflector The deflector style <br /> dictates the appropriate installation position of the sprinkler, it breaks the solid stream of water issuing from the sprinkler orifice to <br /> form a specific spray pattern The following list indicates the various styles and identification of Viking sprinklers <br /> UPRIGHT SPRINKLER:A sprinkler intended to be installed with the deflector above the frame so water flows upward through the <br /> orifice, striking the deflector and forming an umbrella-shaped spray pat- <br /> tern downward Marked"SSU"(Standard Sprinkler Upright)or"UPRIGHT" <br /> on the deflector Viking Technical Data may be found on <br /> PENDENT SPRINKLER A sprinkler intended to be oriented with the deflec- The Viking Corporation's Web site at <br /> tor below the frame so water flows downward through the orifice, striking http://www.vikinggroupinc.com. <br /> the deflector and forming an umbrella-shaped spray pattern downward The Web site may include a more recent <br /> Marked "SSP'' (Standard Sprinkler Pendent) or 'PENDENT" on the de- edition of this Technical Data Page. <br /> flector <br /> CONVENTIONAL SPRINKLER An "old style" sprinkler intended to be installed with the deflector in either the upright or pendent <br /> position The deflector provides a spherical type pattern with 40 to 60 percent of the water initially directed downward and a <br /> proportion directed upward Must be installed in accordance with installation rules for conventional or old style sprinklers DO <br /> NOT USE AS A REPLACEMENT FOR STANDARD SPRAY SPRINKLERS Marked "C U/P" (Conventional Upright/Pendent)on <br /> the deflector <br /> Form No F_080814 18 12 06 Rev 14.1 P65 Replaces Form No F_080814 Rev 14 1 <br /> (Added P65 Warning) <br />
The URL can be used to link to this page
Your browser does not support the video tag.