2 3 4 5 6 <br /> MECHANICAL LEGEND MECHANICAL ABBREVIATIONS <br /> SYMBOL DESCRIPTION <br /> AFF ABOVE FINISHED FLOOR <br /> ARCH ARCHITECT , <br /> YKEMAN <br /> 1 BLDG BUILDING <br /> A101 SECTION/ELEVATION VIEW BMS BUILDING MANAGEMENT SYSTEM <br /> BTUH BRITISH THERMAL UNITS PER HOUR <br /> 1 CD CONDENSATE ARCHITECTURE + DESIGN <br /> DETAIL VIEW CLG COOLING <br /> A701 CTE CONNECT TO EXISTING <br /> CW COLD WATER <br /> IHP-1 EQUIPMENT TAG CWR CHILLED WATER RETURN <br /> O SHEET NOTE TAG CWS CHILLED WATER SUPPLY <br /> DCVA DOUBLE CHECK VALVE ASSEMBLY <br /> E DOC DIRECT DIGITAL CONTROL <br /> REVISION TAG DHW DOMESTIC HOT WATER E <br /> SIZE 1)IA DIAMETER <br /> 1 DIFFUSER/GRILLE TAG DN DOWNCONSULTANT: <br /> FLOW E EXISTING <br /> 8"z10" RECTANGULAR FREE AREA DUCT ELEV ELEVATION <br /> DIMENSIONS(8"WIDTH x 10"DEPTH) EWT ENTERING WATER TEMPERATURE <br /> ROUND DUCT FREE AREA FC FAN COIL <br /> DIMENSIONS(6"DIAMETER) FC0 FLOOR CLEANOUT <br /> FLEX DUCT FP FIREDPROTECTION <br /> �j AIR DIRECTION GC GENERAL CONTRACTOR E C O T O P E <br /> e GEO GEOTHERMAL <br /> SUPPLY DUCT IN/OUT OF PAGE GPM GALLONS PER MINUTE <br /> EXHAUST/RETURN DUCT IN/OUT OF PAGE GWB GYPSUM WALLBOARD <br /> III HTG HEATING <br /> OT THERMOSTAT HW HOT WATER <br /> HWR HOT WATER RETURN <br /> ICO2 CO2 SENSOR HWS HOT WATER SUPPLY - <br /> INV INVERT <br /> AV �. <br /> L LAVATORY <br /> I] ENVELOPE PENETRATION MECH MECHANICAL <br /> NFA NET FREE AREA <br /> ® PUMP OHP OUTDOOR HEATPUMP <br /> POC PO INT OF CONNECTION <br /> ®O SUPPLY/EXHAUST FAN PLUM PLUMBING e <br /> © PRESSURE GAUGE PSI POUNDS PER SQUARE INCH ♦��� ����♦♦ <br /> REF REFER/REFERENCE <br /> O TEMPERATURE GAUGE RF RELIEF FAN ♦.. <br /> RPBP REDUCED PRESSURE BACKFLOW PREVENTER •`�° -�� <br /> Cd TURNING VANES TYP TYPICAL �' C <br /> UV UNIT VENTILATORS <br /> VTR VENT THRU ROOF <br /> WC WATER CLOSET <br /> WCO WALL CLEAN OUT ♦�y'UNA�`�� <br /> WHF WHOLE HOUSE FAN ►UNA <br /> p PROJECT IDENTIFICATION: D <br /> TENANT <br /> IMPROVEMENTS <br /> FOR <br /> HOPEWORKS <br /> AT <br /> 3315 BROADWAY <br /> EVERETT, WA <br /> Printed Date:08/02/2023 <br /> GREENHECK Job:Hopeworks Station TI <br /> Building Value in Air. Mark:KE-1 <br /> Model:USF-24 MECH - INDOOR HEAT PUMPS BID SET <br /> P.normance Model:USF-24 COOLING HEATING DIMENSIONS ELECTRICAL 08/29/2022 <br /> Quantity Universal Single Width Fan TAG MANUFACTURER MODEL UNIT TYPE OUTDOOR UNIT CAPACITY CAPACITY HEIGHT WIDTH DEPTH WEIGHT VOLTS/PHASE MCA NOTES <br /> Volume(CFM) 4,320 9 <br /> Total External SP(in.wg) 1 Operating Performance IHP-BACK MITSUBISHI PKFY-PO6NLMU-E WALL CASSETTE OHP-KITCHEN.1 6,000 Btu/h 6,7006tu/h 1'-0.. 2'-6" 0'-9" 251b 208VAC/iPH 0.2 INCLUDE GOBI II CONDENSATE PUMP <br /> Operating Power(hp) 1 1.6 12 IHP-KITCHEN.1 MITSUBISHI PLFY-P48NEMU-ER1 CEILINGCASSETTE OHP-KITCHEN.1 48,000 Btu/h 54,000 Btu/h 1'-0" 2'-9" 2'-9" 661b 208VAC/iPH 1.27 <br /> Required Power(hp) 1 IHP-KITCHEN.2 MITSUBISHI PLFY-P48NEMU-ER1 CEILINGCASSETTE OHP-KITCHEN.2 48,000 Btu/h 54,000 Btu/h 1'-0.. 2'-9" 2'-9" 661b 208VAC/iPH 1.27 <br /> Fan RPM 752 This drawing Is: <br /> C _ IHP-OFFICE MITSUBISHI PKFY-PO4NLMU-E WALL CASSETTE OHP-KITCHEN.2 4,000 Btu/h 4,SOO Btu/h 1'-0" 2'-6" 0'-9" 241b 208VAC/iPH 0.2 INCLUDE GOBI II CONDENSATE PUMP 1.Copyright 2017D kem an,Inc. C <br /> Max Fan RPM 1,526 ---- 9 Y <br /> Oper.Frequency(Hz) 60 752 FRPM ©'- ;- -- 2.The Architect's Instrument of Professional Service. <br /> Elevation(It) 2,365 1.2 - 0.9 3.For use on this project only.Obtain Architect's <br /> Start-up Temp.(F) 70 - written permission for any other use or reproduction. <br /> Operating Temp.(F) MECH - MAKE-UP AIR FANS PROJECT Fan Configuration <br /> Size 24 � w L ELECTRICAL <br /> Wheel Type BI 0.8 0.6 3 OPERATING <br /> Arrangement 10 'w O TAG SERVICE/LOCATION MANUFACTURER MODEL FLOW STATIC PRESSURE POWER(HP) VOLTS/PHASE MCA MOP WEIGHT NOTES 20121-031 <br /> Cie. I m a MAU-1 MAKE-UP AIR/KITCHEN GREENHECK SQ-16-VG 3460 CFM 1.7 in-wg 1.48 208VAC/3PH 12 20 2461b INCLUDE FILTER BOX W ITH MERV 13 FILTER.INTEGRATE CONTROLS WITH <br /> Rotation CCW a x KITCHEN HOOD.SEE FOOD SERVICE DRAWINGS FOR CONTROLS <br /> Discharge Poskion UB ,p <br /> ` • <br /> Construction Type PemmLock N 0.4 - �o`C 0.3 <br /> Spark Resistance None <br /> Sc <br /> roll Material `\ MARK DATE DESCRIPTION <br /> Mate Whee l rial Steel O°coj`{S�.- <br /> InletCone Mated,l Steel MECH - EXHAUST FANS <br /> Pedestal Material Steel 0.0 0.0 <br /> Equipment weights 0 1 2 3 4 5 6 7 TAG SERVICE/LOCATION MANUFACTURER MODEL FLOW STATIC PRESSURE MOTOR HP BHP VOLTS/PHASE FLA WEIGHT NOTES <br /> Fan(LMD)(Ib) 341 Volume(CFM)x 1,000 KE-1 KITCHEN EXHAUST/ROOF GREENHECK USF-24-B1 4320 CFM 1.0 in-wg 1-1/2 1.08 208VAC/3PH 6.6 5231b INCLUDE VFD.INTEGRATE CONTROLS WITH KITCHEN HOOD. <br /> Motor/Drive(Ib) 39 SEE FOOD SERVICE PLANS FOR CONTROLS <br /> Accessories(Ib) <br /> Fan Total(11b 3 <br /> Mis°Fan Data O Operating point at Total External SP <br /> Fan Energy index(FEI) 1.67 -Fan curvN� <br /> Outlet Velocity(fUmin) 1,251 - --- mepower curve MECH - OUTDOOR HEAT PUMPS <br /> static Effid-cy(%) 73 COOLING HEATING DIMENSIONS ELECTRICAL <br /> Tip Readinpeed g <br /> Type Standard <br /> Actual fan from vendor TAG LOCATION/SERVICE MANUFACTURER MODEL CAPACITY CAPACITY COP 47F SEER WIDTH DEPTH HEIGHT WEIGHT VOLTS/PHASE MCA NOTES <br /> Shaft Bearing Type Standard is less than 400 bs,no <br /> Bearing Life Calculation Operating Point OHP-KITCHEN.1 PARKING GARAGE MITSUBISHI PUMY-P60NKMU3 60,000 Btu/h 66,000 Btu/h 4.1 20 T-5" T-2" 4'-5" 3021b 208VAC/1PH 36 <br /> L10-Bearing Life(hm) 1,000,000 rooftop structural OHP-KITCHEN.2 PARKING GARAGE MITSUBISHI PUMY-P60NKMU3 60,000 Btu/h 66,000 Btu/h 4.1 20 T-5" T-2" 4'-5" 3021b 208VAC/1PH 36 <br /> Motor and Drives calculations required <br /> M­ Included <br /> So,(hp) 11/2 <br /> B RPM 1725 <br /> CDP nmcn MECH - ENERGY RECOVERY VENTILATORS B <br /> Enclosure ODP <br /> V/C/P 208/60/3 w • <br /> Frame Sim 56 k��••� RECOVERYEFFICIENCY DIMENSIONS <br /> Max Frame Size 215 �. .II78 TAG MANUFACTURER MODEL FLOW SENSIBLE LATENT VOLTS/PHASE HEIGHT WIDTH DEPTH WEIGHT NOTES PRINCIPAL IN CHARGE: <br /> Nameplate Model:USF-243B6-00-02-02 <br /> Location Centered m ERV-1 PANASONIC FV-10VE2 100 CFM 81 81 120VAC/1PH 0'-9" 2'-41/2" 1'-11" 57.00 lb UNIT REQUIRES PLUG-IN POWER.RUN ON PROJECT MANAGER: <br /> Pulley Type Constant OCCUPANCY SENSOR.0.8 W/CFM <br /> Drive Loss(%) 6.2 PROJECT ARCHITECT: <br /> Drives Standard Sound Power by Octave Band JOB CAPTAIN: <br /> Drive Service Factor 1.5 Souna Data e2It r35 125 250 500 1000 2000 '2" 8000 Sones <br /> MCA'(Amps) 8.25 88 73 6e 65 62 57 57 52 1. <br /> MOP' 15 Duteel 80 70 66 66 ez 57 57 et t3a <br /> SCCR'(Kiloamps) 5 aea oo rea,umoo mooreuore. <br /> ao"s�,I use A1o,a,eh o a,aa •a,a ��,• ,aAw.,a••�um.,5rMea a,aa MECH - MOTORIZED DAMPERS <br /> Z:\Malt\Greenheck CAPSUobs\0-Emeraltl Alre CAPS\Hopeworics Station Tl.gfcj ACTUATOR <br /> CAPS 4.41.1100 Generated by:mid <br /> Page 2 of 10 TAG SYSTEM MANUFACTURER MODEL POWER RE TYPE NOTES <br /> MD-ERV.1.E ERV-1 RUSK IN CD40 24V ELEC CLASS I.FAIL OPEN.INEGRATE CONTROL WITH ERV-1 <br /> MD-ERV.1.S ERV-1 RUSKIN CD40 24V ELEC CLASS I.FAIL OPEN.INEGRATE CONTROL WITH ERV-1 <br /> MD-MAU.1 MAU-1 RUSKIN CD40 24V ELEC CLASS I.FAIL OPEN.INEGRATE CONTROL WITH MAU-1 <br /> MECH - DIFFUSERS, LOUVERS, GRILLES <br /> TAG MANUFACTURER MODEL TYPE <br /> 1 TITUS 30ORL DOUBLE DEFLECTION SUPPLY GRILLE <br /> 2 TITUS 5OF EGGCRATE RETURN GRILLE <br /> DRAWING <br /> A MECHANICAL - A <br /> GENERAL NOTES <br /> & SCHEDULES <br /> DRAWING <br /> a <br /> 2 3 4 5 6 <br />