<br /> I. SITE PLAN REQUIREMENTS
<br /> A site plan is required for all residential permit applications.See Residential Site Plan(COE Std
<br /> Dwg:101)sample drawing. Building height calculations are required to be on your site plan.See
<br /> Building Height Handout.
<br /> ❑ If you are doing any site work(grading, rockeries, retaining walls,fence, utility work, pavement
<br /> (new or replaced),drainage systems,etc.)you must show and label them on your site plan and
<br /> submit a Public Works Permit Application with your submittal to permit any work outside of
<br /> your structure.
<br /> ❑ All construction with disturbed land must additionally submit a temporary erosion and
<br /> sedimentation control plan (TESC Plan)see COE Std Dwg 103 sample drawing.
<br /> ❑ All construction with 2000sf or more of new plus replaced hard surfaces(pavement,driveway,
<br /> patio, roof,sidewalk,etc.) must additionally submit a Drainage Plan and a Small Project
<br /> Drainage Report satisfying Minimum Requirements 1-5 per the Stormwater Management
<br /> Manual.
<br /> II. STRUCTURAL PLAN REQUIREMENTS
<br /> • Show all four elevations with roof pitch, materials,finished floor level&plate height(s). Put
<br /> building height calculations on one of the elevation pages.
<br /> • Foundation plan (cross section and plan view)showing: rebar placement,slab,ventilation,
<br /> access,anchor bolts,sill plate,vapor barrier etc...
<br /> • Floor plans showing:each story or level,all rooms labeled for use,dimensions of rooms, location
<br /> of furnace and hot water tank,all plumbing fixtures,multiple studs and/or posts,window and
<br /> door sizes.
<br /> • Total square footage: living space,garage,covered porches,deck(including stairs)
<br /> • Cross section—exterior(s)—all materials/connections.
<br /> • Cross section—interior(s)structural framing.
<br /> • Floor framing plan showing: each story,all support pads, posts, beams,sizes,connections,all
<br /> header sizes/bearing,window sizes/openings/class,types of lumber(species'and grade),
<br /> pressure treated lumber.
<br /> • Stair cross section showing:construction,fire blocking, headroom, handrail size and height, riser
<br /> height and tread depth.
<br /> • Masonry fireplace/chimney detail(s).
<br /> • Building section(s)specific to this structure.
<br /> • Roof framing plan(s)showing:trusses,girder truss, hip master, special trusses. If stick frame
<br /> show: size,species,grade and spacing of all framing members.
<br /> • All structural garage details: plan view,cross section,wall and ceiling separation.
<br /> • All structural deck details: pressure treated wood,all support pads, post& beam sizes,
<br /> connections, ledger detail(s),flashing,guardrail (height/spacing of pickets).
<br /> • Specify option and details for whole house ventilation system.Simply referencing the code
<br /> section does not meet the requirement.
<br /> III. WASHINGTON STATE ENERGY CODE(WSEC)COMPLIANCE(2018 ED)
<br /> • Insulation and fenestration requirements by Component(Table R402.1.1 WSEC)
<br /> • Energy credits(Table 406.2 WSEC)
<br /> O l�J 3200 Cedar Street 425.257.88100 everetteps@everettwa.gov
<br /> Everett,WA 98201 425.257.8857 fax everettwa.gov/permits
<br /> Residential Construction Submittal Checklist(2019) Pa,- 2 of 3
<br />
|