GENERAL NOTES AERIAL VIEW <br /> CODE AND STANDARDS <br /> 1.ALL WORK SHALL COMPLY WITH 2O17 NATIONAL ELECTRIC CODE(NEC),2015 INTERNATIONAL BUILDING CODE <br /> . " �*' <br /> (IBC),2015 INTERNATIONAL RESIDENTIAL CODE(IRC),2015 INTERNATIONAL PLUMBING CODE(IPC),AND ALL STATE BLUE RAVEN <br /> AND LOCAL BUILDING,ELECTRICAL,AND PLUMBING CODES. 11 4 <br /> 2.DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS. ,• 11 <br /> y 1403 N. Research Way <br /> SITE NOTES/OSHA REGULATION — -A i' Orem, UT 84097 <br /> 1.A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. w <br /> 800.377.4480 <br /> 2.THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM. I • WWW.BLUERAVENSOLAR.COM <br /> 3.THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR BUILDING ROOF VENTS. <br /> 4.ROOF COVERINGS SHALL BE DESIGNED,INSTALLED,AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND r CONFIDENTIAL-THE INFORMATION <br /> THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SHALL SERVE TO PROTECT HEREIN CONTAINED SHALL NOT BE <br /> THE BUILDING OR STRUCTURE. USED FOR THE BENEFIT OF ANYONE <br /> lr EXCEPT BLUE RAVEN SOLAR NOR <br /> SHALL IT BE DISCLOSED IN WHOLE OR <br /> SOLAR CONTRACTOR 3 IN PART TO OTHERS OUTSIDE <br /> 1.MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. RECIPIENTS ORGANIZATION,EXCEPT <br /> 2.IF APPLICABLE,MODULE GROUNDING LUGS MUST BE INSTALLED AT THE MARKED GROUNDING LUG HOLES PER IN CONNECTION WITH THE SALE AND <br /> THE MANUFACTURER'S INSTALLATION REQUIREMENTS. • USE OF THE RESPECTIVE EQUIPMENT, <br /> 3.AS INDICATED BY DESIGN,OTHER NRTL LISTED MODULE GROUNDING DEVICES MAY BE USED IN PLACE OF WITHOUT THE WRITTEN PERMISSION <br /> �•STANDARD GROUNDING LUGS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. OF BLUE RAVEN SOLAR LLC.'�� „ <br /> 4.CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO « <br /> LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. <br /> 5.CONDUIT POINT OF PENETRATION FROM EXTERIOR TO INTERIOR TO BE INSTALLED AND SEALED WITH A j NAB C E P <br /> SUITABLE SEALING COMPOUND. '�l <br /> ��r [�_ <br /> 6.DC WIRING LIMITED TO MODULE FOOTPRINT W/ENPHASE AC SYSTEM. / r [ • �` �{jy C E RTI F I E D <br /> 7.ENPHASE WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/SUITABLE WIRING CLIPS. ; �.� ♦n, • Sij(vJ <br /> 8.MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR VOC UNLESS NOT • <br /> . . PV INSTALLATION <br /> AVAILABLE. •� � L �►• • <br /> 9.ALL INVERTERS,MOTOR GENERATORS,PHOTOVOLTAIC MODULES,PHOTOVOLTAIC PANELS,AC �� . " ff__ PROFESSIONAL <br /> PHOTOVOLTAIC MODULES,DC COMBINERS,DC-TO-DC CONVERTERS,SOURCE CIRCUIT COMBINERS,AND ; •~ n� r Scott Gurney <br /> CHARGE CONTROLLERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND f - #PV-011719-015866 <br /> LISTED FOR THE APPLICATION PER NEC 690.4(B). <br /> 10.ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. _ CONTRACTOR: <br /> 11.TERMINALS AND LUGS WILL BE TIGHTENED TO MANUFACTURER TORQUE SPECIFICATIONS(WHEN PROVIDED) i BRS FIELD OPS <br /> IN ACCORDANCE WITH NEC CODE 110.14(D)ON ALL ELECTRICAL CONNECTIONS. <br /> 800-377-4480 <br /> EQUIPMENT LOCATIONS r <br /> 1.PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT • <br /> WILL BE PROVIDED AS PER SECTION NEC 110.26. �� '� �j�/ • <br /> 2.EQUIPMENT INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS + <br /> SPECIFIED BY NEC 690.31(A)AND NEC TABLE 310.15(B). ` �• �'.4 •. Sealed For A <br /> 3.ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC I T . Existing Roof & N. `4 L ,, U <br /> APPLICABLE CODES. • _ • r- <br /> 4.ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. * s ,` ♦ , ♦ � , I Attachment Only Q��Q4 Hn.S,cw bC' O N 0 <br /> ti �',� <br /> PROJECT INFORMATION: o N <br /> NUMBER OF STORIES: 2 'V, P ?F 4G056 0 C N N <br /> CONDUIT RUN: Interior <br /> ECOBEE QTY: 1 Z SFr C�STEtz� �'c� W co N co <br /> LIGHT BULB QTY: 18 S�WAS V:S w � 3: 2 2 <br /> PV METER: Not Required DESIGN CRITERIA SITE SPECIFICATIONS SHEET INDEX W � (— <br /> ROOF TYPE 1 INFORMATION: 4/25/2023 O C W U) U) <br /> WIND SPEED. 110 mph CONSTRUCTION -V-B PV1 -COVER SHEET ~ L <br /> ROOF TYPE: Comp Shingle GROUND SNOW LOAD: 25 Ib/ft2 ZONING: RESIDENTIAL PV2-SITE PLAN Cl) C J. Lu N N <br /> W <br /> FRAMING TYPE: Manufactured Truss WIND EXPOSURE FACTOR: C PV3- ROOF PLAN :3 M 0 > V V <br /> SHEATHING TYPE: TONGUE AND GROOVE SEISMIC DESIGN CATEGORY: D PV4-STRUCTURAL V (n M W Q <br /> ATTACHMENT: SFM Infinity Flashkit PV5- ELECTRICAL 3-LINE DIAGRAM <br /> RACKING: Unirac SFM Infinity @ 48" OC Portrait/72"OC Landscape DRAWING BY: <br /> NUMBER OF ATTACHMENTS: 22 SCOPE OF WORK PV6- ELECTRICAL CALCULATIONS <br /> PV7-WARNING LABELS AND LOCATIONS Brendan Fillmore <br /> ROOF TYPE (2) INFORMATION (/FAPPL/CABLE): INSTALLATION OF UTILITY INTERACTIVE PHOTOVOLTAIC SOLAR SYSTEM AND ANY (ALL OTHERSHEETSASREOU/RED) <br /> SHEETS <br /> *SEE PV4.2 NECESSARY ADDITIONAL WORK NEEDED FOR INSTALLATION. SS- PRODUCT SPEC. PLOT DATE: <br /> April 25, 2023 <br /> PROJECT NUMBER: <br /> SYSTEM TO BE INSTALLED INFORMATION: UTILITY COMPANY: 740345 <br /> DC SYSTEM SIZE: 4 kW DC Snohomish County Public Utilities District <br /> AC SYSTEM SIZE: 2.9 kW AC (PUD) SHEET NAME: <br /> MODULE TYPE: (10) QCells Q.PEAK DUO BILK ML-G10+400 COVER SHEET <br /> INVERTER TYPE: Enphase IQ8PLUS-72-2-US <br /> MONITORING: Enphase IQ Combiner 4 X-IQ-AM1-240-4 PERMIT ISSUER: REVISION: PAGE NUMBER: <br /> City of Everett 0 PV 1 <br />