Table 406.2 <br /> Energy Credits (2015 Code) <br /> OPTION DESCRIPTION CREDITS) Estimated Cost <br /> l a EFFICIENT BUILDING ENVELOPE la: 0.5 <br /> Prescriptive compliance is based on Table R402.1.1 with the following modifications: <br /> Vertical fenestration U 0.28 <br /> Floor R-38 <br /> Slab on grade R-10 perimeter and under entire slab <br /> Below grade slab R-10 perimeter and under entire slab <br /> or <br /> Compliance based on Section R402.1.4: Reduce the Total UA by 5%. <br /> l b EFFICIENT BUILDING ENVELOPE lb: 1.0 <br /> Prescriptive compliance is based on Table R402.1.1 with the following modifications: <br /> Vertical fenestration U =0.25 <br /> Wall R-21 plus R-4 <br /> Floor R 38 <br /> Basement wall R-21 int plus R-5 ci <br /> Slab on grade R-10 perimeter and under entire slab <br /> Below grade slab R-I0 perimeter and under entire slab <br /> or <br /> Compliance based on Section R402.1.4: Reduce the Total UA by 15%. <br /> I c EFFICIENT BUILDING ENVELOPE 1 c: 2.0 <br /> Prescriptive compliance is based on Table R402.1.1 with the following modifications: <br /> Vertical fenestration U =0.22 <br /> Ceiling and single-rafter or joist-vaulted R-49 advanced <br /> Wood frame wall R-21 int plus R-12 ci <br /> Floor R-38 <br /> Basement wall R-21 int plus R-12 ci <br /> Slab on grade R-10 perimeter and under entire slab <br /> Below grade slab R-10 perimeter and under entire slab <br /> or <br /> Compliance based on Section R402.1.4: Reduce the Total UA by 30%. <br /> I d' EFFICIENT BUILDING ENVELOPE Id: 0.5 <br /> Prescriptive compliance is based on Table R402.1.1 with the following modifications: <br /> Vertical fenestration U=0.24 <br /> 2a AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2a: 0.5 <br /> Compliance based on R402.4.12: Reduce the tested air leakage to 3.0 air changes per <br /> hour maximum <br /> and <br /> All whole house ventilation requirements as determined by Section M1507.3 of the • <br /> International Residential Code shall be met with a high efficiency fan(maximum 0.35 <br /> warts/cfm),not interlocked with the furnace fan_Ventilation systems using a furnace <br /> including an ECM motor are allowed,provided that they are controlled to operate at <br /> low speed in ventilation only mode. <br /> To qualify to claim this credit,the building permit drawings shall specify the option <br /> being selected and shall specify the maximum tested building air leakage and shall <br /> show the qualifying ventilation system. <br /> 2b AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2b: 1.0 <br /> Compliance based on Section R402.4.12: Reduce the tested air leakage to 2.0 air <br /> changes per hour maximum <br /> and <br /> All whole house ventilation requirements as determined by Section MI507.3 of the <br /> International Residential Code shall be met with a heat recovery ventilation system <br /> with minimum sensible heat recovery efficiency of 0.70_ <br /> To qualify to claim this credit,the building permit drawings shall specify the option <br /> being selected and shall specify the maximum tested building air leakage and shall <br /> show the heat recovery ventilation system. <br />