9. Below grade walls in conditioned spaces are required to be insulated with minimum R-21 on the <br /> interior. Provide section drawing at furred walls. <br /> See Sheet 3 buildimg sectiom. <br /> 10. All headers shall be insulated with minimum R-10 rigid insulation per Table R402.1.1 WSEC. <br /> Show on plans. <br /> See Sheet 4 typical wall sectiom. <br /> 11. Projections located in the five-foot side yard setback shall be protected with one-hour fire- <br /> resistance rated construction on the underside of the projection with no openings allowed. <br /> Provide detail for one-hour fire-resistance rated construction at projections. <br /> See mote ovt Sheet 3. <br /> 12. Projections shall not extend more than 18 inches into the required setback.The proposed <br /> fireplace extends two feet into the setback, please revise. <br /> See Sheet 2 S 3. <br /> 13. A minimum of 75% of lamps in permanently installed lighting fixtures shall be HIGH-EFFICACY <br /> lamps. Provide note on drawings. <br /> See mote om Sheet 2. <br /> 14. The slab-on-grade in the garage shall slope to the main vehicle entry doorway. <br /> See Sheet 3 buildivtg sectiom A. <br /> 15. Provide minimum 36-inch landing not more than 7-3/4 inches below the finished floor at all <br /> entrance/exits.Show on plans. <br /> See Sheet 2. <br /> 16. Specify size and location of all egress windows in entire dwelling. <br /> See Sheet 2. <br /> 17. Show how the Family room in the Basement is provided with light per section R303.1 IRC. <br /> See Sheet 2 -- interior wall partition removed. <br /> 18. Specify which"Whole House Ventilation System"will be used for compliance with section <br /> M1507.3 IRC. Show the requirements of the section chosen, do not simply reference the code <br /> section. <br /> See mote om Sheet 2 - second Floor exist fauvtdry. <br /> 19. Show water heater equipment type,minimum equipment efficiency and location on plans. <br /> See Sheet 2 basewtemt level. <br /> 20. Verify through calculations that the existing north basement foundation wall is capable of <br /> supporting a vehicle surcharge. <br /> See Sheet 3 building section A. <br /> Sincerely, <br /> Jeff Heilman <br /> Development Technician <br />
The URL can be used to link to this page
Your browser does not support the video tag.