Project:Mike Wilkinson page <br /> Location:6x6 DF2 POST @ MSTR BEDRM OPEN RAILING AmericanHomePlanners <br /> Column ' 2812 Colby Avenue of <br /> [2015 International Building Code(2012 NDS)] Everett WA 98201 <br /> 5.5 IN x 5.5 IN x 8.0 FT <br /> #2-Douglas-Fir-Larch-Dry Use StruCalc Version 9.0.2.5 7/12/2018 5:12:27 PM <br /> -Section Adequate By: 36.4% <br /> VERTICAL REACTIONS LOADING DIAGRAM <br /> Live Load: Vert-LL-Rxn= 6800 lb <br /> Dead Load: Vert-DL-Rxn= 4636 lb <br /> Total Load: Vert-TL-Rxn= 11436 lb <br /> COLUMN DATA <br /> Total Column Length: 8 ft <br /> Unbraced Length(X-Axis)Lx: 8 ft - <br /> Unbraced Length(Y-Axis)Ly: 8 ft <br /> Column End Condtion-K(e): 1 <br /> Axial Load Duration Factor 1.00 <br /> COLUMN PROPERTIES <br /> #2-Douglas-Fir-Larch <br /> Base Values Adjusted <br /> Compressive Stress: Fc= 700 psi Fc'= 595 psi <br /> Cd=1.00 Cp=0.85 <br /> Bending Stress(X-X Axis): Fbx= 750 psi Fbx'= 750 psi <br /> Cd=1.00 CF=1.00 ett <br /> Bending Stress(Y-Y Axis): Fby= 750 psi Fby'= 750 psi <br /> Cd=1.00 CF=1.00 <br /> Modulus of Elasticity: E= 1300 ksi E'= 1300 ksi <br /> Column Section(X-X Axis): dx= 5.5 in <br /> Column Section(Y-Y Axis): dy= 5.5 in <br /> Area: A= 30.25 in2 <br /> Section Modulus(X-X Axis): Sx= 27.73 in3 <br /> Section Modulus(Y-Y Axis): Sy= 27.73 in3 <br /> Slenderness Ratio: Lex/dx= 17.45 <br /> Ley/dy= 17.45 A <br /> Column Calculations(Controlling Case Only): AXIAL LOADING <br /> Controlling Load Case:Axial Total Load Only(L+D) <br /> Actual Compressive Stress: Fc= 378 psi Live Load: PL= 6800 lb <br /> Allowable Compressive Stress: Fc'= 595 psi Dead Load: PD= 4584 lb <br /> Eccentricity Moment(X-X Axis): Mx-ex= 0 ft-lb Column Self Weight: CSW= 52 lb <br /> Eccentricity Moment(Y-Y Axis): My-ey= 0 ft-lb Total Load: PT= 11436 lb <br /> Moment Due to Lateral Loads(X-X Axis): Mx= 0 ft-lb <br /> Moment Due to Lateral Loads(Y-Y Axis): My= 0 ft-lb <br /> Bending Stress Lateral Loads Only(X-X Axis): Fbx= 0 psi <br /> Allowable Bending Stress(X-X Axis): Fbx'= 750 psi <br /> Bending Stress Lateral Loads Only(Y-Y Axis):Fby= 0 psi <br /> Allowable Bending Stress(Y-Y Axis): Fby'= 750 psi <br /> Combined Stress Factor: CSF= 0.64 <br /> NOTES <br /> C d/4702 <br />