Laserfiche WebLink
Project:Mike Wilkinson page <br /> Location:6x6 HF#1 POST @ GREAT RM GIRDER SIC AmericanHomePlanners <br /> Column 2812 Colby Avenue of <br /> (2015 International Building Code(2012 NDS)] Everett WA 98201 <br /> 5.5IN x 5.5IN x 17.0 FT <br /> #1 -Hem-Fir-Dry Use StruCalc Version 9.0.2.5 7/12/2018 5:12:35 PM <br /> -Section Adequate By: 12.7% <br /> VERTICAL REACTIONS LOADING DIAGRAM <br /> Live Load: Vert-LL-Rxn= 4000 lb <br /> Dead Load: Vert-DL-Rxn= 2823 lb <br /> Total Load: Vert-TL-Rxn= 6823 lb <br /> COLUMN DATA <br /> Total Column Length: 17 ft <br /> Unbraced Length(X-Axis)Lx: 17 ft V <br /> Unbraced Length(Y-Axis)Ly: 17 ft <br /> Column End Condtion-K(e): 1 <br /> Axial Load Duration Factor 1.00 <br /> COLUMN PROPERTIES <br /> #1 -Hem-Fir <br /> Base Values Adjusted <br /> Compressive Stress: Fc= 850 psi Fc'= 258 psi <br /> Cd=1.00 Cp=0.30 <br /> Bending Stress(X-XAxis): Fbx= 975 psi Fbx'= 975 psi <br /> Cd=1.00 CF=1.00 17 ft <br /> Bending Stress(Y-Y Axis): Fby= 975 psi Fby'= 975 psi <br /> Cd=1.00 CF=1.00 <br /> Modulus of Elasticity: E= 1300 ksi E'= 1300 ksi <br /> Column Section(X-X Axis): dx= 5.5 in <br /> Column Section(Y-Y Axis): dy= 5.5 in <br /> Area: A= 30.25 in2 <br /> Section Modulus(X-X Axis): Sx= 27.73 in3 <br /> Section Modulus(Y-Y Axis): Sy= 27.73 in3 <br /> Slenderness Ratio: Lex/dx= 37.09 <br /> Ley/dy= 37.09 A <br /> Column Calculations(Controlling Case Only): <br /> Controlling Load Case:Axial Total Load Only(L+D) AXIAL LOADING <br /> Actual Compressive Stress: Fc= 226 psi Live Load: PL= 4000 lb <br /> Allowable Compressive Stress: Fc'= 258 psi Dead Load: PD= 2727 lb <br /> Eccentricity Moment(X-X Axis): Mx-ex= 0 ft-lb Column Self Weight: CSW= 96 lb <br /> Eccentricity Moment(Y-Y Axis): My-ey= 0 ft-lb Total Load: PT= 6823 lb <br /> Moment Due to Lateral Loads(X-X Axis): Mx= 0 ft-lb <br /> Moment Due to Lateral Loads(Y-Y Axis): My= 0 ft-lb <br /> Bending Stress Lateral Loads Only(X-X Axis): Fbx= 0 psi <br /> Allowable Bending Stress(X-X Axis): Fbx'= 975 psi <br /> Bending Stress Lateral Loads Only(Y-Y Axis):Fby= 0 psi <br /> Allowable Bending Stress(Y-Y Axis): Fby'= 975 psi <br /> Combined Stress Factor: CSF= 0.87 <br /> NOTES <br />