My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1511 OAKES AVE 2025-01-27
>
Address Records
>
OAKES AVE
>
1511
>
1511 OAKES AVE 2025-01-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2025 3:34:56 PM
Creation date
11/21/2024 9:37:49 AM
Metadata
Fields
Template:
Address Document
Street Name
OAKES AVE
Street Number
1511
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
81
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project:Mike Wilkinson page <br /> Location:30x30x10 fTG @ WET BAR stmcale AmericanHomePlanners <br /> Footing .�- ` 2812 Colby Avenue of <br /> [2015 International Building Code(2012 NDS)] :. Everett WA 98201 <br /> Footing Size:2.5 FT x 2.5 FT x 10.00 IN <br /> Reinforcement:#4 Bars @ 5.88 IN.O.C.EMI/(5)min. StruCalc Version 9.0.2.5 7/12/2018 5:13:13 PM <br /> ',Section Footing Design Adequate <br /> FOOTING PROPERTIES LOADING DIAGRAM <br /> , Allowable Soil Bearing Pressure: Qs= 1500 psf <br /> Concrete Compressive Strength: F'c= 2500 psi <br /> Reinforcing Steel Yield Strength: Fy= 40000 psi <br /> Concrete Reinforcement Cover: c= 3 in <br /> FOOTING SIZE <br /> Width: W= 2.5 ft <br /> Length: L= 2.5 ft <br /> Depth: Depth= 10 in <br /> Effective Depth to Top Layer of Steel: d= 6.25 in <br /> COLUMN AND BASEPLATE SIZE <br /> Column Type: Steel <br /> Column Width: m= 4 in <br /> Column Depth: n= 4 in <br /> Baseplate Width: bsw= 6 in <br /> Baseplate Length: bsl= 6 in <br /> FOOTING CALCULATIONS <br /> Bearing Calculations: <br /> Ultimate Bearing Pressure: Qu= 1076 psf <br /> Effective Allowable Soil Bearing Pressure: Qe= 1375 psf <br /> Required Footing Area: Areq= 4.89 sf <br /> Area Provided: A= 6.25 sf 10 I" <br /> Baseplate Bearing: i — <br /> Bearing Required: Bear= 9672 lb 31n <br /> Allowable Bearing: Bear-A= 99450 lb <br /> Beam Shear Calculations(One Way Shear): <br /> Beam Shear: Vu1 = 2015 lb 2.5 ft —� <br /> Allowable Beam Shear: Vc1 = 14063 lb <br /> Punching Shear Calculations(Two Way Shear): FOOTING LOADING <br /> Critical Perimeter: Bo= 45 in Live Load: PL= 4000 lb <br /> Punching Shear: Vu2= 8312 lb Dead Load: PD= 2727 lb <br /> Allowable Punching Shear(ACI 11-35): vc2-a= 63281 lb Total Load: PT= 6727 lb <br /> Allowable Punching Shear(ACI 11-36): vc2-b= 79688 lb Ultimate Factored Load: Pu= 9672 lb <br /> Allowable Punching Shear(ACI 11-37): vc2-c= 42188 lb Weight to resist uplift w/1.5 F.S.: U.R.= 503 lb <br /> Controlling Allowable Punching Shear: vc2= 42188 lb <br /> Bending Calculations: <br /> Factored Moment: Mu= 25189 in-lb <br /> Nominal Moment Strength: Mn= 209907 in-lb <br /> Reinforcement Calculations: <br /> Concrete Compressive Block Depth: a= 0.62 in <br /> Steel Required Based on Moment: As(1)= 0.11 in2 <br /> Min.Code Req'd Reinf. Flex.Members(ACI-10.5.1):As(2)= 0.94 in2 <br /> Controlling Reinforcing Steel: As-reqd= 0.94 in2 <br /> Selected Reinforcement: #4's @ 5.9 in.o.c.e/w(5)Min. <br /> Reinforcement Area Provided: As= 0.98 in2 <br /> Development Length Calculations: <br /> Development Length Required: Ld= 15 in <br /> Development Length Supplied: Ld-sup= 9.5 in <br /> Note:Plain concrete adequate for bending, <br /> therefore adequate development length not required. <br /> NOTES <br />
The URL can be used to link to this page
Your browser does not support the video tag.