Laserfiche WebLink
• 0 <br /> BeamChek v2016 licensed to:archstudio"r.shadyrya" Reg#7992-66445 <br /> Unnyk Residence entry <br /> post#5 Prepared by: Date: 10/25/16 <br /> Selection 6x 6 DF-L#2 Solid Wood Column <br /> Conditions NDS 2012, Using values for 5x+solid sawn,Posts and Timbers. <br /> Data Load 7208# Column Area 30.25 in2 Kf 1.00 <br /> Actual Height 9.0 ft le dl Effective Ht 108 in c 0.80 <br /> Unbraced L1 9.0 ft le d2 Effective Ht 108 in KcE 0.30 <br /> Unbraced L2 9.0 ft Ke Buckling Mode 1.0 FcE 1012 <br /> Attributes and Values Controlling d is 5.5 inches Fc 11(psi)E(psi x mil) <br /> Reference Values 700 1.3 <br /> le/d psi Area(in2) Adjusted Values 561 1.3 <br /> Actual 20 238 30.25 CF Size Factor 1.00 <br /> Critical 50 561 12.85 Cd Duration 1.00 <br /> Status OK OK OK Cm Wet Use 1.00 1.00 <br /> Ratio 40% 42% 42% Cp Stability 0.80 <br /> Note:A wood plate under this column must have an Fc value,perpendicular to the grain,greater than 238 psi. <br /> 818 <br />