10705 HOLLY DR 2025-01-23
>
Address Records
>
HOLLY DR
>
10705
>
10705 HOLLY DR 2025-01-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/23/2025 7:39:24 AM
Creation date
11/21/2024 10:01:26 AM
Metadata
Fields
Template:
Address Document
Street Name
HOLLY DR
Street Number
10705
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
72
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
z <br /> Handrails shall not project more than 4-1/2 inches (114 mm) on either side of the stairway <br /> and the clear width of the stairway at and below the handrail height, including treads and <br /> landings, shall be not less than 31-1/2 inches (787 mm) where a handrail is installed on <br /> one side and 27 inches (698 mm) where handrails are provided on both sides. <br /> R311.7.2 Headroom. The headroom in stairways shall be not less than 6 feet 8 inches <br /> (2032 mm) measured vertically from the sloped line adjoining the tread nosing or from the <br /> floor surface of the landing or platform on that portion of the stairway. <br /> 6. The stairs to the Master Bedroom do not appear to provide the minimum required <br /> headroom. Show how the existing roof structure will be modified to gain the required <br /> headroom over the stairs. <br /> 7. Please verify the area of all additions and the area of the garage being converted into living <br /> space. Area calculations are based on the dimensions to the outside of exterior walls. <br /> 8. Provide a minimum 36 inch landing measured in the direction of travel at the front door. <br /> Landing shall be at least as wide as the door. If 4 or more risers are present, provide a <br /> handrail per section R311.7.8 IRC. Show on plans. Show a landing at the rear door from <br /> the Recreation Room and at Bedroom #5. Specify 7-3/4 inch maximum rise. <br /> 9. The details on sheet A04 show brick veneer with 3-1/2 inches between the bricks and the <br /> framed wall. The text calls out a one inch air space. Please correct. Specify scale of section <br /> drawings. Callouts on sheet A04 refer to details 1 and 2 on sheet A05. Please correct. <br /> 10. Show new concrete on foundation plan. Use a different symbol to represent existing <br /> concrete and new concrete. <br /> 11. Provide section drawing for new foundation with brick veneer. Show brick veneer on all <br /> plan views and on the section drawing on sheet A11. <br /> 12. Show brick veneer on foundation plan, Lower Floor Plan and on elevations. <br /> 13. The fireplace on the lower level in Bedroom #6 shows the opening on the exterior of the <br /> building. Please correct. <br /> 14. Provide 110 volt smoke alarm with battery backup in the area giving access to the sleeping <br /> rooms on the lower floor level. R314 IRC <br /> If you have any questions, please email or call me at (425) 257-8976. Upon submittal of the <br /> drawings, your application will be given priority and plan reviews will recommence. All required <br /> submittals shall be sufficient detail and contain sufficient information to ensure that the proposed <br /> structure will be constructed in compliance with all adopted codes. <br /> Please prepare a response letter showing where each item in this correction <br /> letter is addressed on the plan set. <br /> Page 3 of 4 <br /> CITY OF EVERETT . 3200 Cedar Street • Everett, WA 98201 • (425) 257-8810 . Fax (425) 257-8857 <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.