20•ashington State Energy Code—Residential <br /> Prescriptive Energy Code Compliance for All Climate Zones in W ington <br /> Single Family—New&Additions(effective February 1,2021) <br /> Table 406.3—Energy Credits(Single Family) <br /> Option Description Credits:SF <br /> 2.AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION OPTIONS <br /> Only one option from Items 2.1 through 2.4 may be selected in this category. <br /> Compliance based on R402.4.1.2:Reduce the tested air leakage to 3.0 air changes per hour <br /> maximum at 50 Pascals or <br /> For R-2 Occupancies,optional compliance based on Section R402.4.1.2: Reduce the tested <br /> air leakage to 0.3 cfm/sf maximum at 50 Pascals and <br /> All whole house ventilation requirements as determined by Section M1507.3 of the <br /> International Residential Code or Section 403.8 of the International Mechanical Code shall <br /> 2.1 be met with a high efficiency fan(s)(maximum 0.35 watts/cfm), not interlocked with the 0.5 <br /> furnace fan(if present).Ventilation systems using a furnace including an ECM motor are <br /> allowed,provided that they are controlled to operate at low speed in ventilation only <br /> mode. <br /> To qualify to claim this credit,the building permit drawings shall specify the option being <br /> selected and the maximum tested building air leakage,and shall show the qualifying <br /> ventilation system and its control sequence of operation. <br /> Compliance based on Section R402.4.1.2:Reduce the tested air leakage to 2.0 air changes <br /> per hour maximum at 50 Pascals or <br /> For R-2 Occupancies,optional compliance based on Section R402.4.1.2: Reduce the tested <br /> 2.2 air leakage to 0.25 cfm/sf maximum at 50 Pascals and 1.0 <br /> All whole house ventilation requirements as determined by Section M1507.3 of the <br /> International Residential Code or Section 403.8 of the International Mechanical Code shall <br /> be met with a heat recovery ventilation system with minimum sensible heat recovery <br /> efficiency of 0.65.1 <br /> Compliance based on Section R402.4.1.2: <br /> Reduce the tested air leakage to 1.5 air changes per hour maximum at 50 Pascals or <br /> For R-2 Occupancies,optional compliance based on Section R402.4.1.2:Reduce the tested <br /> 2.3 air leakage to 0.25 cfm/sf maximum at 50 Pascals and 1.5 <br /> All whole house ventilation requirements as determined by Section M1507.3 of the <br /> International Residential Code or Section 403.8 of the International Mechanical Code shall <br /> be met with a heat recovery ventilation system with minimum sensible heat recovery <br /> efficiency of 0.75.1 <br /> Compliance based on Section R402.4.1.2: <br /> Reduce the tested air leakage to 0.6 air changes per hour maximum at 50 Pascals or <br /> For R-2 Occupancies,optional compliance based on Section R402.4.1.2:Reduce the tested <br /> 2.4 air leakage to 0.15 cfm/sf maximum at 50 Pascals and 2.0 <br /> All whole house ventilation requirements as determined by Section M1507.3 of the <br /> International Residential Code or Section 403.8 of the International Mechanical Code shall <br /> be met with a heat recovery ventilation system with minimum sensible heat recovery <br /> efficiency of 0.80.Duct installation shall comply with Section R403.3.7.1 <br /> 1 To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall <br /> specify the maximum tested building air leakage and shall show the heat recovery ventilation system. <br /> Prescriptive Path—Single Family 2018 Washington State Energy Code-R 5 1/ (? <br />
The URL can be used to link to this page
Your browser does not support the video tag.