Laserfiche WebLink
Douglas Almond <br /> NuttyCAD Drafting and Design, LLC <br /> Plan Check Number: B2206-024, First Building Review <br /> September 15, 2022 <br /> Comments <br /> 1. See energy credits on Sheet 03. It appears that a heating option in Table R406.2 was not <br /> selected. The required number of credits should be normalized per Table R406.2. <br /> 2. It appears the project was designed by a licensed Washington State engineer. Drawings should <br /> include the engineer of record's seal and signature. RCW 18.43.070 <br /> 3. Drawings should specify the requirements for the window well. Providing a reference to the <br /> code section does not satisfy this requirement. Provide construction details of the window well. <br /> Currently, the plans are not clear how the window well will be constructed. Note that <br /> cantilevered retaining walls supporting more than 48 inches of unbalanced backfill require an <br /> engineered design. R310.2.3 <br /> 4. Drawings should specify support requirements of the beams. The connection from the floor <br /> joists to the W8x40 beam should be specified. R106.1.1 <br /> This review has been performed for general compliance with the building codes as adopted and <br /> amended by the state of Washington and the city of Everett. Corrections and comments made <br /> during the review process do not relieve the project from compliance with code and permit <br /> requirements. The designers-of-record are responsible for a complete design in accordance with <br /> the laws of the state of Washington. <br /> If you have any questions or require additional clarification, please contact us. <br /> Respectfully, <br /> Rakeeb Khan <br /> Residential Plans Examiner <br /> (425)257-7263 <br /> rkhan@everettwa.gov <br /> S:\RKhan\2022\B2206-024—Rl.docx <br /> 3200 Cedar Street © 425.257.8810 O everetteps@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page 2 of 2 <br />