Laserfiche WebLink
1. THE SCOPE OF WORK FOR 1115 PROJECT S UMITCI)TO EXTERIOR Bank of America <br />_ LIGHTING RENOVATIONS AS SHOWN ON THE PLANS. <br /> 2 ALL PROPOSED LIGHTS WILL BE FULL CUTOFF LED LIGHT FOCTURES. <br /> 3 ALL PROPOSED EXISTING LIGHTS THAT WILL BE REPLACED SHALL <br /> WILL BE REPLACED WITH FULL CUT OFF LED LIGHT FIXTURES. <br /> 4 REFERENCE THE WMINAIRE SCHEDULE(SHEET LU-2)FOR - ` `` <br /> ADDITIONAL LIGHT FIXTURE INFORMATION 0.0 0.0 0.0 0.0 0A 0.1 0.1 02 02 0.3 0.4 0.4 0.4 0.4 0.3 <br /> BLUE=NEW FIXTURE <br /> 0 0 0.0 0.0 0.1 0.1 0.1 32 02 %.4 0.9 0.9 0.8 0.9 c_. <br /> 0.7 0.5 GREEN=EXISTING FIXTURE LOCATION TO BE REPLACED <br /> ORANGE=EXISTING FDGURE TO REMAIN <br /> / TURQUOISE=FIXTURE TO BE REMOVED <br /> J I PINK=REPLACE WITH NEW POLE AT NEW HEIGHT <br /> 00 0.0 0.1 02 0.3 0.3 3.8 1.8 2.3 3.2 2.3 1.8 1.9 1.7 1.3 0.9 i ...-•PROPERTYLNEBABEDON COUNTYAPPRARM. <br /> NFORWTON <br /> --•BURIED ELECTRICAL CRCULT <br /> GENERAL NOTE:CONTRACTOR SHALL 0.0 0.1 0.3 1.1 3.2 7.0 4.8 5.1 HA 7.3 4.1 3.5 3.1 2.B 2.1 1.8 <br /> VARIANCE FOR LIGHTING MUNICIPAL LEVELS. <br /> YC1 YC1 I YC1 YC1 SF1. 8F1 <br /> SBt <br /> ..... ■ <br /> GENERAL NOTE <br /> [16 8.84.8433.73.83.022 <br /> CONTRACTOR SHALL GET MUNICIPALVARIANCE FOR LIGHTING TEMPS <br /> i4 7 5.7 42 42 4.4 3.9 3A <br /> GENERAL NOTE: ASSOCIATE ENTRY . <br /> PHOTOMETRCSS' <br /> ON THIS PAGE 000 q(�.AGt <br /> REPRENSENTS NEW LIGHTS AND DOES <br /> NOT INCLUDE CONTRIBUTIONS FROM <br /> COSTING1 <br /> FDCURES THAT ARE TO I 113 7.5 5.9 5.5 5.5 5.3 4.0 <br /> REMAIN. ATM2 <br /> W2 <br /> ATM1 • BA1 <br /> ■ <br /> 133 12.1 7.6 8.0 6.3 6.1 R7 Ro <br /> W OBEY ENTRY W <br /> ■ OY1 <br /> m <br /> Q 1 12.9 9.9 8.1 6.6 6.4 6.5 6.8 1€ Q <br /> -E �1 <br /> ` yLN <br /> C7 A.g �AG1 h <br /> 10A 7.1 6.0 6.1 6.3 5.8 <br /> UU1 YC1 <br /> SF1 le 4.0 9.1 8.1 5.1 5.2 5.1 3.9 <br /> YC1 <br /> • <br /> AG1J <br /> wA 6.7 7.3 8.3 4.9 4.4 3.7 2.9 <br /> YC1 YC1 YC1 SF2 <br /> 0.0 0.0 0.0 0.0 0.1 0.3 1.1 3.7 8.4 10.3 7.1 4.8 4.1 3.9 3.0 22 <br /> I- 0.0--0.0---5,0---0.0---N' ---0.2---Ab - 3---28--�1.0 - .3.._-.6,3--3.8--3A ..--2.5.- 0- 1b- <br /> 0.0 0.0 0.0 0.0 0.1 0.1 0.1 1.6 2.3 2.7 2.4 2.2 1.9 1.6 1.2 0.9 <br /> 1 <br /> 0.0 0.0 0.G 0.0 0.0 0.0 0.3 0.5 0.7 0.9 0.9 1.0 1.0 0.9 0.7 0.5 <br /> 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.3 0.3 0.4 0.4 0.5 0.5 0.4 0.3 SCALE: 3/32" = 11-0" <br /> SE Everett Mall Way V1 240108 <br /> O FULL SITE PHOTOMETRICS PLAN _-- __-- _ _._.. _- <br /> 3/32'=1.-0. _.._- --__ <br /> A <br /> WARM M.,1,ox MAIM <br /> IC C. <br /> Qy��$�( <br /> 111:61t G"R <br /> ,,,,,,,„.."„ LP <br /> Greentree Plaza <br /> sioruaEec\ 02/08/2024 305 SE Everett Mall Way, <br /> L� <br /> Everett,WA 98208 <br /> 0 G I S I E FULL SITE PHO OMETTR CS PLAN <br /> DOWNED SS <br /> COO Awes RAI,M6 x oAAL � 4IM e 21-41C8(T) MVO DRAWN� MVO <br /> THIS LIGHTING PLAN ILLUSTRATES ILLUMINATE LEVELS CALCULATED FROM Arreau[Der. <br /> LABORATORY DATA UNDER CONTROLLED CONDITIONS IN ACCORDANCE WITH AWD KRM <br /> CALCULATION SUMMARY FULL SITE ILLUMINATING ENGINEERING SOCIETY OF NORTH AMERICAN(I ES NA)APPROVED SEHEHH <br /> Calculation Points Name Average Maximum Minimum AvellABn Max/Min METHOIRS. MAYVARYAL EUE ILLUMINATION LEVELSANDWEATHER,ELECTRICAL <br /> O LU-4 <br /> _._.. METHODCE INL MPSN ETOVATIONL VELS PERFODCNDITIVOLTAGE, <br /> FULL SITE®GRADE 2.8 fc 14.415 0.0 1C 0.0 fc 0.0 1C TOLERANCE IN LAMPS AND OTHER RELATED VARIABLE FIELD CONDITIONS. <br /> THIS PLAN SET IS PROPRIETARY AND CONFIDENTIAL INFORMATION OF THE BANK AND THE USE OF THIS DESIGN IS PROHIBITED WITHOUT THE EXPRESS PERMISSION OF THE BANK <br />