My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2418 74TH ST SE 2023 Plans 2024-11-26
>
Address Records
>
74TH ST SE
>
2418
>
Plans
>
2418 74TH ST SE 2023 Plans 2024-11-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/26/2024 10:40:43 AM
Creation date
11/26/2024 10:39:59 AM
Metadata
Fields
Template:
Address Document
Street Name
74TH ST SE
Street Number
2418
Permit
B2301-019
Year
2023
Notes
INSTALLATION OF (4) HELICAL PILES TO STABILIZE FOUNDATION
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7 of 21 <br /> A PROJECT NO. SHEET NO. <br /> �,�� S221006-2XR <br /> ��ice` , <br /> � PROJECT 2418 74th St SE Everett WA 98203 <br /> LONGITUDE SUBJECT Foundation Stabilization/Jacking <br /> ONE TWENTY° <br /> ENGINEERING&DESIGN BY JT DATE 11/19/2022 <br /> Ideal Foundation Systems 2 7/8"0 Helical Pile(0.203-inch wall thickness)-Soil Capacity per ESR-3750 <br /> DIGGA SK Drive Head r Torque Correlation Factor, Ultimate Axial Compressive Allowable Axial Compressive <br /> Torque, T <br /> Pressure Kt Capacity Capacity <br /> (Ps+) lft•1bs) Compression,(ft-t) P.=KIT,(lips) P.=0.5•P.,(kips) <br /> 500 1,554 9 14.0 7.0 <br /> 600 1,865 9 16.8 8.4 <br /> 700 2,176 9 19.6 9.8 <br /> 800 2,486 9 22A 11.2 <br /> 900 2,797 9 25.2 12.6 <br /> 1000 3,108 9 28.0 14.0 <br /> 1100 3,419 9 30.8 15.4 <br /> 1200 3,730 9 33.5 16.8 <br /> 1300 4,040 9 36.4 18.2 <br /> 1400 4,351 9 39.2 19.6 <br /> 1500 4,662 9 42.0 21.0 <br /> 1600 4,973 9 44.8 22.4 <br /> 1700 5,284 9 47.6 23_8 <br /> 1800 5,594 9 50.3 25.2 <br /> 1900 5,905 9 53.1 26.6 <br /> 2000 6,216 9 55.9 28.0 <br /> MAX 2100 6,527 9 58.7 29.4 <br /> i)DIGGA 5K Drive Head differential pressure display to torque output has been pulled from the attached conversion charts provided by DIGGA. <br /> it)Per Table 5A of ESR-3750,the maximum installation torque rating of a 2-7/8"V helical pile(0.203-inch wall thickness)is 8,300 fibs.Per Ideal <br /> Manufacturing,Inc,the maximum installation torque rating of a 2-7/8"O helical pile(0.203-inch wall thickness)is 8,000ft•lbs.Final installation <br /> torque shall not exceed the lesser of these limiting values. <br /> iu_)Piles shall reach a torque that correlates with an allowable capacity that meets or exceeds the maximum allowable load demand as listed in the <br /> structural package,bin shall not exceed the maximum allowable capacity for any part of the pile assembly. <br /> iv)Refer to ESR-3750 and Ideal Manufacturing Inc. documents for additional information and requirements. <br /> v_)Definitions per ESR-3750: <br /> T=Final Installation torque inft•lbs;the last torque reading taken during pile installation,using,for example,the <br /> torque reading instruments connected to the installation equipment. <br /> Kt=Torque correlation factor per ESR-3750 <br /> P.=Ultimate axial compressive capacity(in kips)of helical pile <br /> P.=Allowable axial compressive capacity(in kips)of helical pile <br /> vi.)For torque readings between those listed,use the following equation to determine the allowable capacity:P.=(1 K)/2 <br /> vii.)1 kip=1,000 lbs <br /> L120 ENGINEERING&DESIGN <br />
The URL can be used to link to this page
Your browser does not support the video tag.