Laserfiche WebLink
SITE PLAN LEGEND PILE SPACING&LOAD REQUIREMENTS TABLE •,p... <br /> MAX O.C.SPACING,ft MIN VERTICAL CAPACITY,kips PROOF TESTING LOAD,kips a5,..:..; <br /> PILE#PILE TYPE 200%MIN VERTICAL CAPACITY LOCATION <br /> EXISTING RESIDENCE STRUCTURE BTWN PILES END OFFSET ALLOWABLE LOADING <br /> (MIN ULTIMATE CAPACITY) �/ <br /> EXISTING ADJACENT STRUCTURE 1-2 9.0 k/PILE 18.0 k/PILE EXTERIOR •• •' <br /> N $1.0._ HELICAL 8'-0" PER PLAN N,vaLE,. <br /> 3-4 12.0 k/PILE 24.0 k/PILE EXTERIOR • ' <br /> AREA OF PROPOSED WORK NOTES: <br /> ' PROPERTY LINE a. MINIMUM AND MAXIMUM INSTALLATION TORQUE FOR HELICAL ASSEMBLIES SHALL BE SPECIFIED BY THE PILE <br /> MANUFACTURER.THE MINIMUM INSTALLATION TORQUE SHALL BE HIGH ENOUGH TO ACHIEVE THE REQUIRED BEARING <br /> CAPACITY LOADING,INCLUDING A SAFETY FACTOR NO LESS THAN 2.THE MAXIMUM INSTALLATION TORQUE SHALL NOT <br /> APPROXIMATE DIMENSION EXCEED THE ALLOWABLE TORSIONAL CAPACITY OF THE PILE SHAFTS OR ANY PART OF THE PILE ASSEMBLY.MAXIMUM <br /> INSTALLATION TORQUE RATING OF 8,300FT'LBS FOR A 2-7/8 INCH DIAMETER HELICAL PILE WITH 0.203 INCH SHAFT WALL <br /> THICKNESS PER ESR-3750. <br /> b. FOR HELICAL PILES,PER IDEAL GROUP DWG NO.:278TFG,THE ALLOWABLE STRUCTURAL CAPACITY FOR THE 2 7/8" <br /> TRU-FORCE UNDERPINNING BRACKET IS LIMITED TO 30 KIPS. <br /> c. HELICAL ASSEMBLIES AS MANUFACTURED BY IDEAL MANUFACTURING,INC., IN ACCORDANCE WITH ESR-3750. <br /> d. PILE OR ANCHOR LOADS NOT TO EXCEED MAXIMUM CAPACITY AS DETERMINED BY THE MANUFACTURER FOR ANY PART <br /> —sent°—SEWER—g p,,it gy_ OF THE ASSEMBLY. <br /> ' -a_g"`- ^—=E .—gam.—g,.,�, e. MAXIMUM ON-CENTER SPACING LISTED FOR TYPICAL PILE INSTALLATION UNLESS NOTED OTHERWISE ON PLAN. W <br /> —w, —.., — .—w,.E.—w,�Rw„ 74TH ST SE ,E ._ .—Eh Tg„�,—gam„—g„�_�„ —.4�Ag —g»�—g�._,E .—g�— 0 > <br /> _ _sy FOUNDATION NOTES <br /> Z <br /> PROPERI'LINE _•17/A�__ 1. VERIFY ALL DIMENSIONS ON SITE. <br /> 86'-0 ' !�•_.�"--_-_- 2. FOUNDATION DIMENSIONS ARE TO OUTSIDE FACE OF CONCRETE STEM WALL PER RBR LEVEL SURVEY. 7 W <br /> T y 3. REFER TO THE FOLLOWING DETAILS FOR ADDITIONAL INFORMATION L z O, <br /> I / 1 HELICAL PILE 1/SD-1.1 O Z <br /> LT <br /> ¢rn 1 I 4. REFER TO STRUCTURAL CALCULATIONS PACKAGE DATED NOVEMBER 19TH,2022,FOR ADDITIONAL INFORMATION,SPECIFICATIONS, <br /> Z O ; AND REQUIREMENTS. J <br /> a c I (E)CHIMNEY co 5. LEVEL SURVEY PER MR REPAIR PLAN DATED SEPTEMBER 11TH,2022.REFER TO STRUCTURAL CALCULATIONS PACKAGE FOR <br /> y } 25'-O I MODIFICATIONS AND ADDITIONAL REQUIREMENTS FOR REPAIR PLAN. <br /> }"I 29'-Q" Z-0 1 T-O" .�" 6. MINIMUM PILE DIAMETER SHALL BE 2-7/8'. <br /> 7. IT IS ACCEPTABLE TO INSTALL PILES AT THE SPACING SHOWN WITH t 0-6•TOLERANCE TO ALLOW FOR UNEXPECTED OBSTRUCTIONS `..�� <br /> ENCOUNTERED DURING PILE INSTALLATION PROVIDED THAT NO TWO ADJACENT SPANS EXCEED THE SPACING LIMITATION AS INDICATED <br /> ON LEVEL SURVEY. . <br /> 9. FIELD VERIFY ALL EXISTING STEM WALLS AT AND BETWEEN PILE ATTACHMENT LOCATIONS ARE 8•THICK MINIMUM WITH 7-8'HEIGHT / <br /> (MEASURED FROM B/FTG TO TICONC)MINIMUM. <br /> 10.PARCEL DIMENSIONS NOT TO SCALE.PROPERTY LINE AND RESIDENCE LOCATING DIMENSIONS(WITH ASTERISK,')APPROXIMATED PER <br /> I SNOHOMISH COUNTY MAP.NOT TO BE USED FOR LEGAL PURPOSES. <br /> 11.SITE FEATURES AND EXISTING STRUCTURES ON ADJACENT PARCELS NOT SHOWN FOR CLARITY. <br /> o <br /> ,.....- <br /> '7' I 12.PILES SHALL BE INSTALLED TOA MINIMUM EMBEDMENT OF 5'-0"(UNO PER GEOTECHNICAL REPORT). <br /> --- --- <br /> I RESIDENCE i <br /> N CO 2418 74TH ST <br /> I EVERETT,WA 98203 0.1 <br /> I HELICAL PILE REFUSAL CRITERIA: <br /> I TORQUING OF THE PILE SHALL CONTINUE UNTIL A HYDRAULIC PRESSURE IS ACHIEVED TO PROVIDE THE SPECIFIED MINIMUM VERTICAL - <br /> _ • <br /> _ CAPACITY WITH A SAFETY FACTOR OF NO LESS THAN TWO.ADVANCEMENT SHALL BE HALTED IMMEDIATELY IF THE STRUCTURE BEGINS <br /> 1 I TO EXPERIENCE UPLIFT FLEXURE. <br /> I I _ <br /> 1 2426 74TH ST <br /> I I I EVERETT,WA 98203 <br /> 1 I <br /> } I • <br /> i <br /> • <br /> 54-0 ; -1' 2418 74TH ST <br /> Lull io EVERETT <br /> l' m WA 98203 <br /> 241074TH ST "'I� <br /> EVERETT,WA 98203 w l Fa �I <br /> .m ,o <br /> AREA OF WORK •m ................... <br /> al!d teo!IeH= ;, <br /> a• (E)STRUCTURE I '----'-'------_ S221006-2XR <br /> I SISod 6U!IS!X3= <br /> lJT <br /> I 1 MRT <br /> 1 - _ i�I bl 0 b/l_ 8n .4z wi.- <br /> i I - I.)AL0 11/19/2022 <br /> q I 9/9- <br /> I I 0 z/L- Z/L- <br /> i I z/L- 9/L- <br /> iPARCEL NO. I <br /> E21- <br /> i 0 39877003 0201 I , gels JOAo Joo1d 4 M ® bit- ;® s ® ® Lam„ <br /> LEGAL DESCRIPTION I ti3NHOO WOBd Ri# <br /> BUENA VISTA HOME TRACTS b/l L- <br /> BLK 003 D-01-N 85FT OF LT 2 I 3l de3J.V3O1 L <br /> EXC W 3FT THOF I 7 �- <br /> I OWNER NAME S ADDRESS I ?II. L- ZXVW 0/3/ z VO 00 <br /> I SERRANO ARMANDO . .0-2 <br /> MARTIN/KAYLAJOELLE I '. Z/L_ Z./L- Z/L' .0V/L- g G_ 4' Z <br /> 2418 74TH ST I-- L WE - <br /> • EVERETT,WA 98203 I 174 <br /> • ----;� - <br /> PROPERTYLINE --•— —.—"—"—•—•—•—"--- —•— <br /> • <br /> R&R LEVEL SURVEY z <br /> See Structural Calculation Package for Additional Requirements _ N <br /> NOTE: THE PROJECT WILL NOT RESULT IN CHANGING OF SITE TOPOGRAPHY OR EXISTING DEVELOPED AREAS. SITE PLAN 1al <br /> — <br />