1917 127TH PL SE 2022 Plans 2024-11-26
>
Address Records
>
127TH PL SE
>
1917
>
Plans
>
1917 127TH PL SE 2022 Plans 2024-11-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/26/2024 10:59:16 AM
Creation date
11/26/2024 10:59:07 AM
Metadata
Fields
Template:
Address Document
Street Name
127TH PL SE
Street Number
1917
Permit
B2206-036
Year
2022
Notes
FOUNDATION STABILIZATION - (7) PUSH PIERS & (5) WALL ANCHORS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL REQUIREMENTS PUSH PIERS (CONT.) <br /> REFER TO SUBSEQUENT PLAN AND DETAIL NOTES FOR VARIATIONS AND EXISTING UTILITY LINES: rillirillIllr0-iVASiliiREQUIREMENTS SPECIFIC TO REFERENCED PROJECT. r�.� '7�.CONTRACTOR TO REPAIR UTILITY LINES THAT MAY BE DAMAGED DURING INSTALLATION. aNOTES ON DRAWINGS TAKE PRECEDENCE OVER GENERAL STRUCTURAL NOTES. <br /> PUSH PIER SPLICING: -�DESIGN CRITERIA PILES ARE TO BE GRAVITY SPLICED WITH FITTING COUPLERS. BUILDING WEIGHT WILL ENSURE /.. SFA Design Group, u.c <br /> JOINTS DO NOT SEPARATE. ` ,�y '""o`I"L"`an""" ""'�" <br /> Portland,Oft I LNermnre,CA S WA <br /> 2y <br /> BUILDING CODE CONFORMANCE (MEETS OR EXCEEDS REQUIREMENTS): TESTING & INSPECTION I <br /> o��sjONA o � <br /> 2018 INTERNATIONAL BUILDING CODE (IBC) CONTINUOUS SPECIAL INSPECTION IS REQUIRED DURING INSTALLATION PER 2018 IBC SECTION 1810.4.12. <br /> 2018 INTERNATIONAL RESIDENTIAL CODE (IRC) THE SPECIAL INSPECTOR IS RESPONSIBLE FOR VERIFYING AND RECORDING THE FOLLOWING: EXPIRES: 04/04/24 U <br /> 2018 WASHINGTON BUILDING CODE J <br /> 2018 WASHINGTON RESIDENTIAL CODE • PROJECT DESCRIPTION (ADDRESS, INSTALLATION DATE, PERMIT NUMBER —! <br /> DEAD LOADS: • PILE AND BRACKET CONFIGURATION <br /> ROOF DEAD LOAD 15 PSF • PART DESCRIPTION (PRODUCT MANUFACTURER, BRACKET TYPE, PIER TYPE, PIER OUTSIDE DIAMETER, PIER WALL �_ Z <br /> FLOOR DEAD LOAD 15 PSF THICKNESS) Q z <br /> WOOD WALL DEAD LOAD 12 PSF • PIER INCLINATION, LOCATION, DEPTH, AND INSTALLATION PRESSURE ACHIEVED fi <br /> INTERIOR WALL DEAD LOAD 9 PSF w a <br /> DECK DEAD LOAD 12 PSF LOAD TESTING SHALL BE PERFORMED IN ACCORDANCE WITH ASTM METHOD D1143 (QUICK METHOD) ON 20 PERCENT OF cr w w o <br /> CONCRETE 150 PCF ,� _. PIERS AND WILL BE SELECTED BY THE SPECIAL INSPECTOR. AN ALIGNMENT LOAD (AL) SHALL BE APPLIED TO THE PILE 0 (/) N <br /> CITY Y OF tVtRETT PRIOR TO SETTING THE DEFLECTION MEASURING EQUIPMENT TO ZERO OR A REFERENCE POSITION. THE AL SHALL BE NO Z Z _1 rn <br /> LIVE LOADS: REVIEWED FOR PERMIT MORE THAN 10% OF THE DESIGN LOAD. INCREMENTAL LOADING SHALL BE IN ACCORDANCE WITH THE FOLLOWING O D a' Q <br /> ROOF SNOW LOAD 25 PSF SCHEDULE. I•— U E- <br /> DECK LIVE LOAD 60 PSF < Z � ��--- <br /> FLOOR LIVE LOAD (RESIDENTIAL) 40 PSF TEST LOADING SCHEDULE HOLD TIME MAX DEFLECTION o p r W <br /> AL (.10 DL MAX) 0 MIN. ti CC <br /> PUSH PIERS 0.25 DL UNTIL STABLE Z w w <br /> 0.50 DL UNTIL STABLE �— <br /> MATERIALS: 0.75 DL UNTIL STABLE ® p w <br /> BRACKET PLATES — ASTM A36 1.00 DL UNTIL STABLE U- cc <br /> (MIN YIELD STRESS, Fy = 36 KSI / MIN TENSILE STRESS, Fu = 58 KSI) 1.25 DL UNTIL STABLE >a. w <br /> PIER TUBES — ASTM A500 GRADE B OR C 1.50 DL HOLD FOR CREEP TEST (SEE BELOW) 0.04 INCHES W Q <br /> (MIN YIELD STRESS, Fy = 50 KSI / MIN TENSILE STRESS, Fu = 55 KSI) <br /> EXTERNAL SLEEVE — ASTM A500 GRADE B 1.00 DL UNTIL STABLE " <br /> 1.00 DL UNTIL STABLE i : <br /> (MIN YIELD STRESS, Fy = 50 KSI / MIN TENSILE STRESS, Fu = 62 KSI) 0.75 DL UNTIL STABLE < <br /> PIER CAP — ASTM A529 GRADE 50 0.50 DL UNTIL STABLE 2 <br /> (MIN YIELD STRESS, Fy = 50 KSI / MIN TENSILE STRESS, Fu = 65 KSI) 0.25 DL UNTIL STABLE <br /> COIL ROD — ASTM A193 GRADE B7 <br /> (MIN YIELD STRESS, Fy = 105 KSI / MIN TENSILE STRESS, Fu = 125 KSI) LOAD TESTING CREEP ACCEPTANCE CRITERIA SHALL BE NO GREATER THAN 0.04 INCHES WITHIN A 10 MINUTE PERIOD. IF <br /> STEEL ANGLE SHAPES — ASTM A36 MOVEMENT IS OBSERVED GREATER THAN 0.04 INCHES WITHIN THE 10 MINUTE PERIOD THE LOAD TEST SHALL BE HELD FOR <br /> (MIN YIELD STRESS, Fy = 36 KSI / MIN TENSILE STRESS, Fu = 58 KSI) AN ADDITIONAL 50 MINUTES, THE PIER IS TO BE DEEPENED AND RE—TESTED, OR THE PIER IS TO BE ABANDONED AND GENERAL NOTES <br /> REPLACED WITH A NEW PIER. IF THE LOAD TEST IS TO BE HELD THE PIER MOVEMENTS SHALL BE MEASURED AT 15, 20, <br /> WELDING NOTES: 30, 40, 50, AND 60 MINUTES. THE CREEP VERSUS THE LOGARITHM OF TIME SHALL BE PLOTTED. IF THE CREEP RATE IS <br /> CONFORM TO AWS D1.1. WELDERS SHALL BE CERTIFIED IN ACCORDANCE WITH AWS LESS THAN 0.080 INCHES BETWEEN 6 AND 60 MINUTES, THE LOAD TEST SHALL BE CONSIDERED SUCCESSFUL. REVISIONS <br /> REQUIREMENTS. USE E70 ELECTRODES OF TYPE REQUIRED FOR MATERIALS TO BE WELDED. <br /> PUSH PIER TEST PRESSURE (PSI): [DESIGN LOAD] X 1.5 / [AREA OF HYDRAULIC RAM]. <br /> CORROSION PROTECTION: <br /> SACRIFICIAL DESIGN THICKNESS — CAPACITIES INCLUDE A SCHEDULED LOSS IN STEEL THICKNESS SAFEBASE WALL ANCHOR SYSTEM <br /> DUE TO CORROSION FOR BLACK, UNCOATED STEEL. ANCHORS ARE DESIGNED FOR 50—YEAR <br /> SCHEDULED SACRIFICIAL THICKNESS LOSS IN ACCORDANCE WITH ICC—ES AC358. • WALL It: SIZE= SAFEBASE 11x18x11GA ASTM A1011 CS TY B, OR 12"x31"x11GA ASTM A1011 CS TY B <br /> INSTALLATION: HOT DIP GALVANIZED PROJRE22 04N1O: <br /> SYSTEM TO BE INSTALLED PER MANUFACTURERS RECOMMENDATIONS. MINIMUM INSTALLATION DESIGNED BY: <br /> PRESSURE IS TO BE DETERMINED BY THE FOLLOWING EQUATION: • EARTH PLATE: SIZE= SAFEBASE 16"x24"x7GA ASTM A1011 CS TY B MEK <br /> HOT DIP GALVANIZED DRAWN BY: <br /> MEK <br /> PUSH PIER INSTALLATION PRESSURE (PSI): [DESIGN LOAD] X 2 / [AREA OF HYDRAULIC RAM]. CHECKED BY: <br /> CVR, <br /> THREADED ROD: 3/4-10x78" ASTM F1554 GRADE 55, HOT DIP GALVANIZED DATE: JLD <br /> MINIMUM INSTALLATION DEPTH IS 10'-0"t UNO. LOCKING ROD END: 21/8x1.15 NUT 3/4-10 THREAD ASTM A563/1045, NICKEL PLATED 05.18.202E <br /> NOTIFY ENGINEER IF MINIMUM INSTALLATION CONDITIONS CANNOT BE ACHIEVED. LOCKING COUPLER: 3x1 3/4-10 THREAD ASTM A563, NICKEL PLATED SHEET NO: <br /> SOCKET WASHER: 2x0.245 ASTM A563, NICKEL PLATED <br /> BALL NUT: 1x11/4 NUT 3/4-10 THREAD ASTM A563, NICKEL PLATED Si ■l <br />