EXHAUST FANS EXHAUST FANS GENERAL NOTES <br /> FAN SP MIN. DRIVE DAMPER FAN INLET FAN SP MIN. DRIVE DAMPER FAN INLET <br /> MARK LOCATION SERVICE TYPE MFR. MODEL CFM N. RPM HP ELECT. TYPE TYPE SIZE REMARKS MARK LOCATION SERVICE FAN MFR. MODEL CFM IN. RPM HP ELECT. TYPE TYPE SIZE REMARKS <br /> W.G. TYPW.G. <br /> EF-200 ROOF DINKING HOODED AEROVENT TWB-48 25,000 0.125 750 5 480/3/60 BELT BED 54"x54" EF-246 ROOF MEZZANINE HOODED AEROVENT TWB-48 25,000 0.125 750 5 480/3/60 BELT BED 54"x54" <br /> PROP. ROOF PCA PROP, ROOF <br /> VENTILATOR I VENTILATOR <br /> EF-201 ROOF FOAM ROUT HOODED AEROVENT TWB-48 25,000 0.125 750 71/2 480/3/60 BELT BED 54"x54" EF-247 ROOF MEZZANINE HOODED AEROVENT TWB-48 25,000 0,125 750 5 480/3/60 BELT BDD 54"x54" <br /> PROP. ROOF PCA PROP. ROOF <br /> VENTILATOR VENTILATOR <br /> EF-202 ROOF STOWBIN ASSY. HOODED AEROVENT TWB-48 25,000 0.125 750 5 480/3/60 BELT BDD 54"x54" EF-248 ROOF MEZZANINE HOODED AEROVENT TWB-48 25,000 0.125 750 5 480/3/60 BELT BDD 54"x54" <br /> THRU &TOOL PROP. ROOF PCA PROP, ROOF <br /> EF-207 STORAGE VENTILATOR VENTILATOR <br /> EF-208 ROOF NEW PRESS HOODED AEROVENT TWB-48 20,000 0.125 615 3 480/3/60 BELT BDD 54"x54" EF-249 ROOF MEZZANINE HOODED AEROVENT TWB-48 25,000 0.125 750 5 480/3/60 BELT BDD 54"x54" <br /> & AREA PROP. ROOF PCA PROP. ROOF <br /> EF-209 VENTILATOR VENTILATOR <br /> EF-210 ROOF CRUSH CORE HOODED AEROVENT TWB-48 25,000 0.125 750 5 480/3/60 BELT BDD 54"x54" EF-250 ROOF HOODED AEROVENT TWB-54 33,500 0.125 692 7.5 480/3/60 BELT BDD 67 1/2x <br /> THRU BLANKING, PROP. ROOF M VAC. PROP, ROOF 67 1/2 <br /> EF-212 STOWBIN VENTILATOR PUMP ROOM VENTILATOR <br /> EF-213 ROOF CRUSH CORE HOODED AEROVENT TWB-48 23,490 0.125 700 5 480/3/60 BELT BDD 54"x54" EF-251 ROOF HOODED AEROVENT TWB-54 33,500 0.125 692 7.5 480/3/60 BELT BDD 67 1/2x <br /> THRU BLANKING, PROP. ROOF M VAC. PROP. ROOF 67 1/2 <br /> EF-217 STOWBIN VENTILATOR PUMP ROOM VENTILATOR <br /> EF-218 ROOF INSERT, HOODED AEROVENT TWB-48 25,000 0.125 750 5 480/3/60 BELT BDD 54"x54" EF-252 ROOF HOODED AEROVENT TWB-30 6,000 0.250 928 480/3/60 BELT BDD 35 3/4x <br /> SWEEP & PROP. ROOF MEZZ. PROP. ROOF 35 3/4 <br /> SAND VENTILATOR SCREEN WASH VENTILATOR <br /> EF-219 ROOF STOWBIN HOODED AEROVENT TWB-48 22,500 0.125 865 5 480/3/60 BELT BDD 54"x54" EF-253 ROOF MEZZ HOODED AEROVENT TWB-36 14,000 0.125 891 3 480/3/60 BELT BDD 41 3/4x <br /> & BOND PROP. ROOF MOPS PROP. ROOF 41 3/4 <br /> EF-220 VENTILATOR VENTILATOR <br /> EF-221 ROOF STOWBIN HOODED AEROVENT TWB-48 25,000 0.125 750 5 480/3/60 BELT BDD 54"x54" EF-254 ROOF PROP. ROOF 35 3/4 HOODED AEROVENT TWB-30 6,000 0.125 811 3/4 120/1/60 BELT BDD 35 3/4x <br /> MEZZ. <br /> THRU ASSEMBLY ROP. ROOF INDICIA EF-225 VENTILATOR VENTILATOR <br /> EF-226 ROOF KITCHEN CENTRIFUGAL AEROVENT G12 CV 220 .5 1550 1/20 120/1/60 DIRECT BDD 15"xl5" EF-255 ROOF SWEEP AND CENTRIFUGAL AEROVENT� BIA 15,840 2.0 1202 10 �480-3-60 BELT BUTTERFLY 53 3/4 WITH ROOF CURB AND <br /> TRASH ROOM EXHAUSTER SAND IN-LINE 800-32 BDD 53 3/4 STACK CAP <br /> EXHAUST ROOF MT'D <br /> EF-227 ROOF HAZ. MAT. UTILITY SET x EF-256 DELETED <br /> UPBLAST VG ECM CONSTRUCTION. <br /> Tiin City Fan 182-TSI 3700 1.00 1396 1 460/3/60 Belt NONE 24"x24 <br /> 0 S O T F G P - 4 0. 1 1 D 1'x21' EF-257 DELETED <br /> EXHAUSTER <br /> B <br /> EF-229 ROOF STOWBIN ASSY. HOODED AEROVENT TWB-48 28,000 0.125 820 7.5 480/3/60 BELT BDD 54"x54 EF-258 ROOF KITCHEN CENTRIFUGAL GAYLORD 480/3/60 BELT TO BE PART <br /> & &TOOL DROP. ROOF HOOD UP BLAST OF MAU-101 SYSTEM <br /> EF-230 STORAGE VENTILATOR EXHAUSTER SEE MAU-101 SCHEDULE CONSTRUCTION NOTES <br /> EF-231 ROOF STOWBIN HOODED AEROVENT TWB-48 28,500 0.125 830 7.5 480/3/60 BELT BDD 54"x54" EF-259 ROOF DISHWASHER CENTRIFUGAL HARTZELN B 122 A 600 1.0 1560 1/3 115/1/60 BELT BDD 12"x12" <br /> THRU ASSEMBLY DROP. ROOF HOOD UP BLAST REMOVE AND REPLACE EXHAUST FAN SERVING <br /> EF-232 VENTILATOR EXHAUSTER HAZMAT ROOM WITH MAKE AND MODEL <br /> NOT USED. REMOVED WITH EF-260 MEZZANINE AC-101 IN-LINE PENN EX-20 3600 0.75 1200 2 480/3/60 BELT NONE 28" INDICATED ON SCHEDULE. MODEL ON <br /> BLOCKHOUSE DEMO. RETURN CENTRI- SCHEDULE SERVES AS BASIS OF DESIGN. <br /> EXHAUST FUGAL ALTERNATE'S SHALL BE SUBMITTED TO BOEING <br /> FOR APPROVAL. <br /> EF-234 ROOF EAST UPBLAST ALRQY fJT -_61&-B 2600 1--er 1.5 480/3/60 2-BELT BDD 22"x22" SPACE CONVERTED TO POTTING EF-261 ROOF PRESS AREA HOODED AEROVENT TWB-48 20,000 0.125 615 3 480/3/60 BELT BDD 54"x54" <br /> BLOCK HOUSE PENNBARRY FX18BH ROOM - EXHAUST HOOD ADDED <br /> CENTRIFUGAL 75 1250 VENTILATION PROP. ROOF FURNISH WITH - <br /> PO TING RM FAN DISINTEGRATED ITSELF VENTILATOR <br /> REPLACEDWITH SIMILARI SPARK B CONSTRUCTION.' ECM MOTOR . <br /> EF-235 ROOF TUNNEL CENTIFUGAL AEROVENT CVB-24 6000 0.50 780 2 480/3/60 BELT BDD 27"x27" EF-262 ROOF PRESS AREA HOODED AEROVENT TWB-48 20,000 0.125 615 3 480/3/60 BELT BDD 54"x54" <br /> THRU BELOW FLOOR EXHAUSTER VENTILATION PROP. ROOF <br /> EF-237 <br /> VENTILATOR <br /> EF-238 ROOF RESTROOM CENTIFUGAL PENN DX18B 2875 1.0 965 1 HP 480/3/60 BELT BDD 20 X 20 EF-263 ROOF THERMOFORM HOODED AEROVENT TWB-48 25,000 0.125 750 5 480/3/60 BELT BDD 54"x54" B <br /> EXHAUSTER VENTILATION PROP. ROOF <br /> VENTILATOR <br /> EF-239 ROOF FOAM ROUT HOODED AEROVENT TWB-54 30,000 0.25 665 7.5 80/3/60 BELT BDD 68"x68" EF-264 ROOF THERMOFORM HOODED AEROVENT TWB-48 25,000 0.125 750 5 480/3/60 BELT BDD 54"x54" <br /> DROP. ROOF VENTILATION PROP. ROOF <br /> VENTILATOR VENTILATOR <br /> EF-240 ROOF MEZZANINE HOODED AEROVENT TWB-48 25,000 0.125 750 5 480/3/60 BELT BDD 54"x54" EF-265 ROOF AC-121 HOODED AEROVENT TWB-48 26,663 0.125 780 5 480/3/60 BELT BDD 54"x54" <br /> TOOL DROP. ROOF EXHAUST PROP. ROOF <br /> STORAGE VENTILATOR VENTILATOR <br /> EF-241 ROOF MEZZANINE HOODED AEROVENT TWB-48 25,000 0.125 750 5 480/3/60 BELT BDD 54"x54" EF-266 ROOF AC-103 HOODED AEROVENT TWB-48 26,663 0.125 780 5 480/3/60 BELT BDD 54"x54" <br /> TOOL DROP. ROOF EXHAUST PROP. ROOF <br /> STORAGE VENTILATOR VENTILATOR <br /> EF-242 ROOF MEZZANINE HOODED AEROVENT TWB-48 25,000 0.125 750 5 480/3/60 BELT BDD 54"x54" EF-267 ROOF OVEN AREA HOODED AEROVENT TWB-48 25,000 0.125 750 5 480/3/60 BELT BDD 54"x54" <br /> PCA DROP. ROOF VENTILATION PROP. ROOF <br /> VENTILATOR VENTILATOR <br /> EF-243 ROOF MEZZANINE HOODED AEROVENT TWB-48 25,000 0.125 750 5 480/3/60 BELT BDD 54"x54" EF-268 ROOF OVEN AREA HOODED AEROVENT TWB-48 25,000 0.125 750 5 480/3/60 BELT BDD 54"x54" <br /> PCA POP. ROOF VENTILATION PROP. ROOF <br /> VENTILATOR VENTILATOR <br /> EF-244 ROOF MEZZANINE CENTRIFUGAL AEROVENT CVB-21 2150 0.625 855 0.50 20/1/60 BELT BDD 21%21" EF-269 ROOF OVEN AREA HOODED AEROVENT TWB-48 25,000 0.125 750 5 480/3/60 BELT BDD 54"x54" <br /> RESTROOMS EXHAUSTER 13G12 CV3 VENTILATION PROP. ROOF <br /> VENTILATOR <br /> EF-245 ROOF ELECT. HOODED AEROVENT TWB-42 12,000 0.50 870 3 80/3/60 BELT BDD 48"x48" EF-270 ROOF AC-104 HOODED AEROVENT TWB-48 26,663 0.125 780 5 480/3/60 BELT BDD 5411x54" <br /> SUB. R0 ROOF EXHAUST PROP. ROOF <br /> VENTILATOR VENTILATOR <br /> SEE DRAWING M2-08 FOR CONTINUATION <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE gCCEPTABLTY AWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> THIS DESIGN ANDITY CHECKED EXHAUST FAN SCHEDULE W9641643 B 02.02.24 <br /> - REPLACED FAILED FAN 7529961 LMS BUDMATS 07.29.08 SPECIFICATION IS APPROVED SHEET <br /> ® ENcwEER TITLE HAZMAT ROOM EXHAUST FAN REPLACEMENT /� \A IRC-WBS 223.3.2 HD VACUUM PUMP RM-RECORD DWG W2572915 SAZAN KLW 07.15.16 BOE/A/G APPROVED BY DEPT. DATE A A'/ O 4 <br /> B HAZMAT ROOM EXHAUST FAN REPLACEMENT W9641643 FIG KTC 02.02.24Im CHECKED �\Y/�L !8 0 <br /> APPROVED BUILDING 40-056 JOB N0, COMP N0.st MO <br /> W9641643 <br /> APPROVED MECHANICAL MASTER EVERETT, WA DWG NO. 40-056—M2-08 <br />