My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1102 SHUKSAN WAY BRIOTECH 2025-01-13
>
Address Records
>
SHUKSAN WAY
>
1102
>
BRIOTECH
>
1102 SHUKSAN WAY BRIOTECH 2025-01-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/13/2025 9:08:15 AM
Creation date
12/1/2024 7:43:39 AM
Metadata
Fields
Template:
Address Document
Street Name
SHUKSAN WAY
Street Number
1102
Tenant Name
BRIOTECH
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DAILY FIELD REPORT Inspection <br /> Date <br /> r AAR TESTING AND INSPECTION, INC. 09/30/2024 <br /> Report <br /> 7126 180th Ave NE, Suite C101, Redmond, WA 98052 1 425-881-5812 Number <br /> JAH093024C <br /> CLIENT INFORMATION PROJECT INFORMATION <br /> Contact Megan Andrews Project No. 24-620 <br /> Company Northwest Handling Systems Project Name Briotech BT Manufacturing (PO#01EA240626F) <br /> Address 1100 SW 7th St Address 1102 Shuksan Way Unit 1 <br /> City Renton City Everett <br /> Contractor Northwest Handling Permit No. B2407-024 <br /> INSPECTION TYPE(S) STRUCTURE(S) / LOCATION(S) <br /> O Proprietary Anchors - Mechanical pallet racks within GL A-D.5/1-3.5, and B-D.5/6-7 <br /> Weather Temperature (OF) Start Time End Time <br /> Sunny 61 01:00 PM 02:30 PM <br /> DRAWINGS/ DOCUMENTS REFERENCED <br /> rack design sheet 3, and ESR Report 4266 <br /> INSPECTION OBSERVATION / REMARKS <br /> As requested, I was on site to inspect the installation of Hilti 1/2"x5 1/2" KB-TZ2 wedge anchors into existing concrete at the above noted <br /> locations for the pallet racks within GL A-D.5/1-3.5, and B-D.5/6-7. When on site I reviewed the rack design sheet 3, and ESR Report 4266. <br /> I verified that the approved anchors were installed to the required embedment depth of 3 1/2"inches. <br /> I used a calibrated torque wrench to verify tightening torque on the anchor nuts and found that the nuts were tightened to at least 40 foot <br /> pounds. <br /> Work was performed per ESR Report 4266, manufacturer's directions and the project plans. <br /> Items inspected are in conformance with approved plans, specifications,and jurisdictional requirements <br /> Inspectors Signature Inspectors Name Report Date Reviewers Reviewed By Reviewed Date <br /> James Huggins 09/30/2024 Signature Teajalam (TJ) <br /> Gounden <br /> 5B3BC01F-44B3-434D-A790-8504523A7083 <br />
The URL can be used to link to this page
Your browser does not support the video tag.