My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
717 HAWTHORNE ST BLDG A 2024-12-30
>
Address Records
>
HAWTHORNE ST
>
717
>
717 HAWTHORNE ST BLDG A 2024-12-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/10/2024 8:00:05 AM
Creation date
12/1/2024 7:44:12 AM
Metadata
Fields
Template:
Address Document
Street Name
HAWTHORNE ST
Street Number
717
Unit
BLDG A
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STRUCTURAL NOTES REINFORCING STEEL: <br /> 0 <br /> q O <br /> CODE: 2018 International Building Code(IBC) Deformed billet steel ASTM A-615, Grade 60, fs = 24,000 psi.unless noted otherwise on w o <br /> the plans. Lap all splices a minimum of 40 bar diameters. Provide elbow bars at wall q a z <br /> LIVE LOADS: corners and intersections to splice horizontal bars. Provide two#5 bars around all ry o x o <br /> Roof 25 psf (snow) openings with a minimum dimension of eleven(11) inches or greater in walls and slabs. y ` 1 <br /> Floor: 40 psf residential Extend the bars 2'-0"beyond openings or as far as possible and hook. Provide one#5 X <br /> Deck: 60 psf (1.5X Occupancy served) 4'-0"center diagonal bar at corners. Any welded wire fabric(WWF) shall conform to w w w <br /> w o�� <br /> Corridors: 100 psf ASTM 185. WWF shall be lapped one crosswire plus two inches (i.e., 8" for 6X6 mesh). <br /> Reinforcing placing drawings shall be prepared by a qualified detailer in accordance with <br /> LATERAL LOADS: A.a the most current ACI detailing manual. Submit placing plans to the structural engineer of <br /> Wind : 85 mph, Exposure "B" moop record prior to fabrication. Any Grade 60 steel requiring bends shall be shop bent only <br /> Seismic: Ss= 1.22 ; S 1 =0.43 fZ;1 j5 C 4W 5 (preheating is required). Cold field bending is allowed only for Grade 40 rebar. <br /> FOUNDATION: All ASTM A-615 (Grade 60)rebar shall be welded according to the most current edition Q <br /> Soils Report Available: No of the American Welding Society (AWS) D12.1-75, "Reinforcing Steel Welding Code". <br /> Design bearing pressure 1500 psf. Any Foundation elevations shown on the plans and Specifically, E90 electrodes shall be used, and the base metal shall be preheated to the <br /> sections are estimated. All footings shall bear on undisturbed earth or compacted fill and temperature specified in the above reference. No weld shall be made within six(6)bar <br /> shall extend to firm bearing when poor bearing is encountered at elevations shown. diameters of any bend. All welders must be WABO certified. a <br /> Compacted fill shall be well-graded granular fill with not more than 5%passing a#200 +-' w <br /> sieve. Fill shall be placed in eight-inch maximum loose lifts and compacted to 95% STRUCTURAL LUMBER& TIMBER: v U <br /> maximum dry density as determined by the compaction procedure in ASTM D-1557. <br /> All lumber shall be graded in accordance with current WWPA standard grading rules for <br /> CONCRETE: Western lumber. Use the following species and minimum grades unless noted otherwise w <br /> on the plans: U c, <br /> Unless noted otherwise on the plans, concrete f c shall be 2500 psi at 28 days. Minimum + <br /> of 5&1/2 sacks of cement per cubic yard of concrete, and a maximum of 6&3/4 gallons Studs and Columns: DFL Standard <br /> of water per 94-pound sack of cement. A standard mix design satisfying the above Wall Plates& Screeds DFL Utility ^, <br /> minimum strength is also acceptable. Provide mix design data to the engineer for review Joists & Rafters DFL #2 <br /> and approval. Header& Flush Beams DFL #2 <br /> 4X Beams DFL #2 A U U U <br /> Add plastocrete or pozzolith in accordance with the manufacturer's recommendations to 6X Beams DFL #1 o <br /> all concrete except footings. Concrete protection for reinforcing: <br /> All plywood shall be APA C-D interior grade with exterior glue and a minimum panel ID <br /> Bottom of footings: 3" index of 42/20 for floors, 32/16 for the roof, and 16/0 for the walls. <br /> Wall exposed to earth: 2" <br /> Wall exposed to weather: 1&1/2" STRUCTURAL AND MISCELLANEOUS STEEL: L P. MSC <br /> Wall inside face: 3/4" <br /> Slabs: 3/4" Structural steel, ASTM A-36, Fb =24,000 psi. maximum. All pipe columns shall be AV <br /> Beams and columns (to ties): 1&1/2" ASTM A53, Grade `B", Fy = 35,000 psi. All tube columns shall be ASTM A500, <br /> Grade"B", Fy =46,000 psi. All welds shall be 3/16"minimum continuous fillet welds <br /> All concrete in footings and walls, slabs and beams shall be poured in a monolithic pour using AWS Class E70 electrodes unless otherwise noted. All welding shall be performed t83 <br /> unless shown otherwise or approved by the structural engineer or record prior to pouring. by welders certified by WABO or equal. All fabrication and erection shall be in C <br /> Aluminum conduit and accessories shall not be embedded in any concrete. accordance with the latest edition of the AISC "Specification for the Design, Fabrication, �S <br /> and Erection of Structural Steel for Buildings". <br />
The URL can be used to link to this page
Your browser does not support the video tag.