Laserfiche WebLink
NW 1/4, SEC. 11 T.28 N, R.4 E, W.M. <br />CITY OFEVERETT, WASHINGTON <br />NOTES <br />1. CONNECTION TO SEWER MAIN PER SEC. 7 OF <br />STANDARD SPECIFICATIONS AND SPECIAL <br />PROVISIONS AND STANDARD DRAWING 602. <br />2. INSTALL 6" MINIMUM PIPE SIZE IN RIGHT OF <br />5' MAXIMUM IF <br />WAY' <br />GREATER THAN 5' <br />3. INSTALL 6" CLEAN OUT PER STANDARD. <br />INSTALL ADDITIONAL <br />DRAWING 604. <br />CLEAN OUT REQUIRED <br />CLEAN OUT AT <br />AT ALL ANGLE POINTS <br />BUILDING CONNECTION. <br />OVER 45° <br />4. PRIVATE SIDE SEWER PIPE DIAMETER: <br />4" MINIMUM FOR SINGLE FAMILY <br />6" MINIMUM FOR ALL OTHER USES. <br />GENERAL NOTES <br />1. SEE SECTION 7 OF STANDARD <br />SPECIFICATIONS FOR ROADS; BRIDGE AND <br />MUNICIPAL CONSTRUCTION WSDOT/APWA <br />AND CITY SPECIAL PROVISIONS SECTION <br />BUILDING <br />7-18 FOR DETAILS AND REQUIREMENTS ON <br />Q <br />LATERALS. <br />0 <br />2. ALL CLEAN OUT'S ON PRIVATE PROPERTY <br />�I <br />ARE TO BE ADJUSTED TO GRADE IF IN PAVED <br />AREAS PER STANDARD DRAWING 604. <br />3. CLEAN OUT'S ARE TO BE CONSTRUCTED <br />WITH WYES OR SANITARY "T"S (SWEEPS). <br />TYPICAL <br />INSTALL <br />STRAIGHT "T"S ARE NOT PERMITTED. <br />CLEAN OUT <br />AT BLDG. <br />4. ALLOWABLE GRADES ARE 2% (1/4"/FT) <br />ALTERNATES <br />CONNECTION <br />MINIMUM TO 100% (FT/FT) MAXIMUM. <br />4 <br />5. SEWER MUST BE STRAIGHT BETWEEN <br />ANGLE POINTS, CHANGES IN LINE OR <br />3 <br />GRADE SHALL BE MADE WITH APPROVED <br />FITTINGS. <br />0 <br />PROPERTY <br />o <br />_ <br />LINE <br />6. NORMALLY ONLY ONE(1) CONNECTION TO <br />2 <br />THE SEWER MAIN PER BLDG. IS ALLOWED. <br />3 <br />TWO (2) DIFFERENT LAYOUTS ARE SHOWN <br />F <br />1 <br />FOR ILLUSTRATIVE PURPOSES ONLY! <br />z <br />0 <br />w <br />SEWER MAIN <br />0 <br />u <br />CITY OF EVERETT <br />PUBLIC WORKS DEPARTMENT <br />a <br />N\ <br />Ciry Engineer 'DRi°n Manager CAD Manager Drawn By urre ev <br />SASS DAVID VOIGT PAULWILHELM WRR 12/30/2016 <br />TITLE 12/30/2016 <br />STANDARD DRAWING Nn. <br />Aao <br />-�a <br />TYPICAL SIDE SEWER LAYOUTS 601 <br />ri- TYPICAL SIDS' SEWER LAYOUTS <br />SW2 N.T.S. (CITY OF EVERETT STD. 601) <br />NOTES <br />1. W = MAXIMUM WIDTH OF TRENCH. FOR PIPES 15" <br />OR LESS IN DIA W=40". FOR PIPES 18" OR GREATER <br />W=1.5 X I.D. + 18". PIPE MUST BE CENTERED IN <br />TRENCH. <br />2. ALTERNATE SLOPING TRENCH WALLTO MEET <br />EXISTING 7 <br />6 <br />8 9 10 <br />O.S.H.A. REQUIREMENTS (NO SLOPES STEEPER THAN <br />PAVEMENT <br />1:1 EXCEPT FOR ROCK). <br />6" <br />18"MIN <br />3. SUITABLE NATIVE MATERIAL OR IMPORTED GRAVEL <br />BORROW AS DIRECTED. COMPACT TO 90% <br />MAXIMUM DENSITY. <br />r - I <br />I <br />4. FOUNDATION GRAVEL IF REQUIRED BY THE <br />I LEI <br />I- -I I -I I --I- <br />ENGINEER TO REPLACE UNSUITABLE MATERIAL. <br />I <br />I -I I _III <br />SHALL BE FOUNDATION MATERIAL CLASS A, B OR AS <br />- <br />-I <br />APPROVED BY THE ENGINEER. <br />� 1 <br />I <br />I <br />5. FOR ADDITIONAL COMPACTION INFORMATION SEE <br />-I <br />III <br />I I/ <br />1 <br />STANDARD DWG 615. <br />1 <br />I/ <br />ICI Y I <br />2 <br />6. IF DIRECTED BY THE ENGINEER THE TOP THREE TO <br />FIVE FEET OF BACKFILL SHALL BE IMPORTED GRAVEL <br />2 <br />� I- <br />BORROW OR SUITABLE NATIVE MATERIAL <br />1 <br />COMPACTED TO 95% MAXIMUM DENSITY. <br />-I <br />7. SEE CITY OF EVERETT STANDARD DWG 326 FOR <br />PAVEMENT PATCH DETAILS. <br />8. VERTICAL TRENCH WALLS WITH SHORING TO <br />III <br />CONFORM TO O.S.H.A. REGULATIONS. <br />8 <br />III- <br />9. SUBGRADE OR GROUND SURFACE IN NON -PAVED <br />AREAS. <br />10. EXCAVATED NATIVE MATERIAL OR STOCKPILED <br />BACKFILL MATERIAL. <br />3 <br />3 <br />11. FOR ALL TRENCHING TRANSVERSE TO THE ROADWAY <br />a <br />w � <br />BACKFILL ABOVE THE PIPE ZONE SHALL BE <br />° <br />Z 1O <br />0 <br />CONTROLLED DENSITY FILL. SEE SECTION 3-9.6 & <br />w <br />3-20.1 OF THESE STANDARDS. <br />3 <br />Z <br />II <br />a w <br />a Ln <br />if <br />12. FOR UTILITY CUTS SUCH AS GAS, TELEPHONE, <br />w <br />POWER, AND CABLE TV LONGITUDINAL TO THE <br />I I <br />ROADWAY, BACKFILL SHALL BE CONTROLLED <br />W <br />- <br />I <br />DENSITY FILL. SEE SECTION 3-9.5 OF THESE <br />= <br />O <br />-I <br />I <br />STANDARDS. <br />a <br />- <br />Z <br />CITY OF EVERETT <br />_I- <br />4 <br />PUBLIC WORKS DEPARTMENT <br />W (SEE NOTE1) <br />06CIT <br />WO <br />SASS DAVIDaVOIGT �APAUL WILHELM ESH <br />tea. <br />TITLERYAN <br />06/23/2017 <br />STANDARD DRAWING No. <br />E61 <br />TYPICAL TRENCH SECTION 614 <br />4 TYPICAL TRENCHSECTION <br />�W2 N.T.S. (CITY OF EVERETT STD. 614) <br />Know what's below. <br />Call before you dig. <br />UTILITY CONFLICT NOTE:• <br />CAUTION - <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, <br />DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE <br />PLANS OR NOT, BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL <br />AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS AND THEN SHALL <br />INCLUDE CALLING UTILITY LOCATE ® 1-800-424-5555 POTHOLING ALL OF THE <br />EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY <br />VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS <br />SHOWN ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC <br />INFORMATION AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, <br />THE CONTRACTOR SHALL CONSULT WITH INSIGHT ENGINEERING COMPANY TO <br />RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. <br />6" GASKETED NOTES <br />6" GASKETED CAST IRON BOLTED RING & COVER SPIGOT CAP OR <br />MECHANICAL 1. CLEAN -OUT PIPE AND FITTINGS SHALL BE PVC, <br />TYPE 1 & 2 (SEE NOTE 5). <br />SPIGOT CAP PLUG TYPE 1 & 2 ASTM D3034, SDR 35 OR AWWA C900. <br />OR <br />MECHANICAL 2. A SANITARY TEE MAY BE INSTALLED IN LIEU OF A <br />PLUG WYE AS SHOWN. STRAIGHT TEES ARE NOT <br />30" SQ <br />TYPE 1 & 2 cr PROPERTY LINE LANDSCAPED OR ACCEPTABLE. <br />UNPAVED SURFACE <br />OR RIGHT-OF-WAY / 3. SEWER STUB WILL BE EXTENDED 10' BEYOND <br />TYP <br />PROPERTY LINE TO PREVENT DAMAGE TO <br />PAVED SURFACE CLEAN OUTAND MINIMIZE CONFLICTS WITH OTHER <br />UTILITIES WHEN SERVICE TO BUILDING IS <br />°a INSTALLED. <br />� A 4. TYPE 3 TEMPORARY INSTALLATIONS (NEW <br />a DEVELOPMENT) SHALL HAVE A PRESSURE TREATED <br />CONCRETE COLLAR SEE NOTES 2"X4" STUB MARKER THAT EXTENDS DOWN TO A <br />(COMMERCIAL CONC) TYP. 6 AND 7 MIN OF 24" BELOW GROUND. A MIN OF 36" SHALL <br />EXTEND ABOVE GROUND. STUB MARKER SHALL BE <br />30" SQTYP. PAINTED WITH WHITE TRAFFIC PAINT. THE WORD <br />SEE STANDARD 12" DIA PVC SLEEVE "SEWER" AND THE DEPTH IN FEET FROM GROUND <br />DRAWING 602 TYP. TYPE 1 & 2 SEE STANDARD SURFACE TO SEWER STUB PIPE INVERT SHALL BE <br />DRAWING 602 PAINTED ON THE MARKER WITH 3" HIGH BLACK <br />SEAL ANNULAR SPACE PAINTED LETTERS. <br />WITH FIBER JOINT <br />TYPE 1 TYPE 2 <br />PACKING OR URETHANE 5. CAST IRON BOLTED RING AND COVER SHALL BE <br />PAVED AREAS FOAM TYP. TYPE 1 & 2 UNPAVED AREAS EAST JORDAN IRON WORKS NO.3660CPT OR <br />PERMANENT INSTALLATIONS EQUAL. <br />cr 6. RING AND COVER INSTALLATION IS SHOWN FOR <br />PAVED AND UNPAVED AREAS, FIELD CONDITIONS <br />STUB MARKER (NOTE 4) WILL DICTATE WHICH INSTALLATION IS <br />SS BOLTS APPROPRIATE. <br />S 12 7/8"MIN <br />W 7. RING AND COVER WITH CONCRETE COLLAR MAY BE <br />E PLACED AT GROUND SURFACE IN UNPAVED AREAS <br />R ❑ ❑ - <br />v DESIRED. <br />1-1ElIF <br />9� El �Tlm <br />x ❑ ❑ ❑ <br />101/2" <br />❑ ❑ ❑ MIN <br />N <br />18"MIN <br />6" GASKETED CAP 10, <br />(NOTE 4) PLAN SECTION <br />12" CAST IRON BOLTED RING AND COVER <br />(SEE NOTE 5) <br />SEE STD CITY OF EVERETT <br />DETAIL 6020:77- <br />PUBLIC WORKS DEPARTMENT <br />TYPE 3 <br />CiryEngineer section Mana er CAD Manager <br />UNPAVED AREA EERYAN SASS DAVID VOIGT PAUL WILHELM wn ESH 03/30/2017 <br />SEWER CLEAN -OUT STANDARD DRAWING No. <br />TEMPORARY INSTALLATION FOR NEW DEVELOPMENT <br />A <br />TYPE 1, 2, 3 & 12" CAST IRON 604 <br />= <br />RING & COVER <br />1 I <br />SEWER CLEA1V OUT TYPE 1,2,3 & 12" CAST IRON RING & COVER <br />N.T.S. (CITY OF EVERETT STD. 604) <br />I <br />NOTES <br />FINAL JOINT MUST <br />1. ALL TRENCHES IN ROADWAY AREAS SHALL BE <br />BE SAWCUT <br />BACKFILLED AND PATCHED WITH TEMPORARY <br />EXISTING ASPHALT ASPHALT AT THE END OF EACH WORK DAY, UNLESS <br />CONCRETE ASPHALT CONCRETE (2" MIN) PERMISSION IS GRANTED TO DO OTHERWISE BY THE <br />TO MATCH EXISTING THICKNESS CITY ENGINEER. <br />EXISTING CEMENT <br />CONCRETE 2. ALL TEMPORARY PATCHES ON TRENCHES SHALL BE <br />6" MIN °,. + .°:. SAWCUT OR LINE DRILL UNDERLYING CONCRETE PERMANENTLY PATCHED WITHIN 2 WEEKS OF <br />COMPLETION OF WORK WITHIN ROADWAY AREA. <br />° 6" MIN CEMENT CONCRETE TO <br />MATCH EXISTING THICKNESS <br />3. CEMENT CONCRETE FOR PATCHING SHALL BE <br />6" MIN CRUSHED SURFACING TOP COURSE COMMERCIAL MIX AS CALLED OUT IN WSDOT <br />STANDARD SPECIFICATIONS. <br />SEE STANDARD DRAWING 614 <br />EXISTING ASPHALT CONCRETE OVER CEMENT CONCRETE <br />FINAL JOINT MUST <br />BE SAWCUT <br />ASPHALT CONCRETE (3" MIN) <br />EXISTING ASPHALT REPLACEMENT PATCH TO BE <br />CONCRETE 1" THICKER THAN PREVIOUSLY EXISTED <br />6" MIN 6" MIN CRUSHED SURFACING <br />TOP COURSE <br />SEE STANDARD DRAWING 614 <br />EXISTING ASPHALT CONCRETE OVER PREPARED GRADE <br />FINAL JOINT MUST <br />3 <br />BE SAWCUT CEMENT CONCRETE (8" MIN) <br />EXISTING CEMENT REPLACEMENT PATCH TO BE <br />w <br />CONCRETE 1" THICKER THAN PREVIOUSLY EXISTED <br />g <br />o <br />PAVEMENT <br />° <br />w <br />d <br />° . <d b ° d ° <br />6" MIN CITY OF EVERETT <br />0 <br />6" MIN CRUSHED SURFACING <br />z <br />TOP COURSE EVERETT PUBLIC WORKS DEPARTMENT <br />aSEE <br />WO <br />o <br />STANDARD DRAWING 614 <ityEngReer unManager AD Manager Drawn By Current Rev Date <br />RYAN SASS TOM HOOD PAULWILHELM Wag 04/26/2017 <br />TITLE <br />a <br />0o <br />STANDARD DRAWIrvG No, <br />EXISTING CEMENT CONCRETE OVER PREPARED GRADE <br />Ear <br />PAVEMENT PATCHING DETAILS 326 <br />('T' PA VEMENT PATCHING DETAILS <br />SW2 N.T.S. (CITY OF EVERETT STD. 326) <br />SEE SHEET 104 PROPERTY LINE SEE SHEET 604 <br />NOTES <br />OR RIGHT-OF-WAY <br />R <br />1. PVC SIDE SEWER CONNECTIONS TO PVC NEW <br />GRADE ELEVATION <br />TYP GRADE ELEVATION IMAINS <br />SHALL BE FACTORY TEES. <br />- <br />6" PVC ASTM <br />-III III <br />2. TYPE A & B SHALL BE USED ONLY WHEN <br />APPROVED D3034, <br />INSTALL SDR35 OR <br />Z <br />g <br />SEWER MAIN DEPTH EXCEEDS 15 FEET OR AS <br />APPROVED BY THE ENGINEER. TYPE D SHALL <br />CAP NOT COUPLING AWWA C900 <br />APPROVED COUPLING <br />BE USED WHEN EXISTING SIDE SEWER IS <br />PLUG <br />SHALLOW (LESS THAN 6' DEPTH AT PROPERTY <br />LINE) <br />"DEEP <br />2% MIN. SLOPE <br />�N <br />3. CONNECTIONS TO EXISTING CONCRETE <br />SOCKET" FITTINGS <br />EXISTING <br />2�� E EXISTING SIDE SEWER <br />SEWER MAINS SHALL BE MADE PER <br />AT EACH END OF <br />SIDE SEWER <br />STANDARD DRAWINGS 612 & 613 OR BY <br />VERTICAL PIPE SECTION <br />6" PVC ASTM D3034. <br />APPROVED MANUFACTURED CONCRETE TEE. <br />"GPK PRODUCTS" OR EQUAL <br />SDR35 OR AWWA C900 PVC SEWER MAIN <br />(SEE CONNECTION <br />4. SEE STANDARD DRAWING 604. WHERE RING <br />NOTES 33) <br />AND COVER INSTALLATIONS ARE SHOWN FOR <br />35°MIN <br />PAVED AND UNPAVED AREAS, FIELD <br />45°MAX <br />CONDITIONS WILL DICTATE WHICH <br />O <br />SANDBAG FILLED WITH 60LBS <br />INSTALLATION IS APPROPRIATE. <br />PVC SEWER MAIN <br />MINIMUM DRY MIX CONCRETE <br />(SEE CONNECTION <br />12" X 12" CIP CONCRETE BLOCK. CONCRETE SHALL BE <br />(OR CONCRETE BLOCK, SAME AS <br />5. CONNECTIONS TO EXISTING HDPE SEWER <br />NOTES 2 & 3) <br />COMMERCIAL CONCRETE MIX AS CALLED OUT IN <br />TYPE "A") <br />MAINS SHALL BE MADE PER STANDARD <br />WSDOT STD SPECS OR SANDBAG FILLED WITH 60LBS <br />DRAWING 612 OR SIDE -WALL FUSION. <br />MIN OF DRYMIX CONCRETE. <br />TYPE "A" <br />TYPE "C" <br />SEE SHEET 604 R SEE SHEET 604 <br />R <br />GRADE ELEVATION GRADE ELEVATION <br />-III I pi IT, <br />I I I I I I- TTT <br />z <br />-I I <br />SHALLOW SIDE SEWER <br />o <br />INSTALL CAP g g <br />EXISTING SIDE SEWER <br />N <br />NOT PLUG <br />6 PVC ASTM D3034, <br />4" OR 6" <br />o <br />APPROVED SDR35 OR AWWA <br />APPROVED COUPLING <br />Z <br />COUPLING C900 <br />Z <br />EXISTING <br />- 6"x6" OR 6"X4" SAN <br />g <br />PVC SEWER MAIN <br />SIDE SEWER <br />j / TEE/WYE <br />> <br />(SEE CONNECTION <br />:drl� <br />35°MIN <br />o <br />NOTES 2 & 3) <br />2% MIN. SLOPE <br />FUTURE DEEPER <br />45°MAX <br />h <br />6" PVC ASTM D3034, SDR35 u <br />SIDE SEWER <br />N <br />35°MIN OR AWWA C900 `= <br />CITY OF EVERETT <br />O'' <br />45°MAX <br />SANDBAG FILLED WITH 60LBS MINIMUM <br />DRY MIX CONCRETE <br />PUBLIC WORKS DEPARTMENT <br />o(OR <br />CONCRETE BLOCK, SAME AS TYPE "A") <br />ciry Engineer awn Cur Si°n Manager AD Manager Or By rent Rev Date <br />eaDAVIDVOIGT <br />$ <br />SANDBAG FILLED WITH 60LBS MINIMUM <br />RVANSASS PAULWILHELM was <br />R 12/30/2016 <br />TYPICAL SIDE SEWER nANDARDDRAWING N°. <br />TYPE 111311 DRY MIX CONCRETE <br />TYPE "D" <br />A a <br />(OR CONCRETE BLOCK, SAME AS TYPE "A") <br />CONNECTIONS 602 <br />TYPE A,B,C,&D <br />3 TYPICAL SIDE SEWER CONNECTIONS <br />SW2 N.T.S. (CITY OF EVERETT STD. 602) <br />SEWER MAIN SYSTEM CONSTR UCTION PLAN NOTES: <br />THE INSTALLATION OF ALL EXTENSIONS TO THE SANITARY SEWER SYSTEM SHALL BE DONE <br />PER PLANS WHICH HAVE BEEN APPROVED BY THE CITY ENGINEER. <br />SANITARY SEWER PLANS ARE TO BE SEPARATE FROM OTHER UTILITY PLANS, BUT ALL <br />OTHER UTILITIES ARE TO BE SHOWN, WITH SANITARY SEWER PORTIONS HIGHLIGHTED. <br />UNLESS APPROVED OTHERWISE, PLANS SHOULD BE PREPARED ON 22 INCH BY 34 INCH <br />PLAN/PROFILE TYPE SHEETS AND SHALL SHOW BOTH PLAN AND PROFILE VIEWS. OTHER <br />UTILITIES ARE TO BE SHOWN IN PROFILE VIEW AND IN PLAN VIEW. <br />THE MINIMUM ALLOWABLE SCALE SHALL BE 1 INCH = 40 FEET, ON SMALL PROJECTS, IT <br />SHALL BE EXPECTED THAT THE SCALE WILL BE ENLARGED TO ADEQUATELY UTILIZE THE <br />FULL PLAN SHEET. <br />PROVIDE NOTES ON PLANS THAT REFER TO SPECIFIC CITY STANDARDS FOR SUCH THINGS <br />AS MANHOLES, DROP CONNECTIONS, SIDE SEWERS, ETC. <br />PLANS SHALL SHOW INVERT ELEVATIONS OF THE MAIN AT THE OUTLET AND ALL INLETS <br />OF EACH MANHOLE, SLOPE OF THE MAIN AND SURFACE ELEVATIONS OF THE MANHOLE <br />LID. IN THE PROFILE VIEW, THE FINISH GROUND ELEVATION OVER THE PIPE SHALL BE <br />SHOWN AS WELL AS CROSSINGS OF OTHER EXISTING OR PROPOSED UTILITIES. STATIONING <br />OF SIDE SEWERS FROM THE DOWNHILL MANHOLE IS REQUIRED. <br />IN ALL CASES WHERE A NEW SEWER LINE IS TO BE LOCATED IN AN EASEMENT, THE <br />EASEMENT IS TO BE SHOWN WITH MEASUREMENT INFORMATION TO ACCURATELY FIELD <br />SURVEY AND STAKE LOCATION PRIOR TO CONSTRUCTING THE PIPE LINE. <br />UPON COMPLETION OF CONSTRUCTION, THE ORIGINAL OF THE PLAN SHALL BE AS -BUILT <br />BY THE DEVELOPER AND CERTIFIED AS AS -BUILT BY HIM AND TURNED INTO THE PUBLIC <br />WORKS DEPARTMENT WITH PROPERLY EXECUTED EASEMENT DEEDS AS APPLICABLE FOR <br />THE PROJECT. <br />SEWER MAIN SYSTEMREQUIRED NOTES: <br />THE FOLLOWING STANDARD NOTES ARE REQUIRED ON ALL SANITARY SEWER PLANS: <br />A. ALL WORK AND MATERIALS SHALL CONFORM TO THE CITY OF EVERETT STANDARDS <br />AND WSDOT/APWA STANDARD SPECIFICATIONS. <br />B. NO PART OF THE SANITARY SEWER SYSTEM SHALL BE COVERED, CONCEALED OR <br />PUT INTO USE UNTIL IT HAS BEEN TESTED, INSPECTED, AND APPROVED BY THE CITY <br />INSPECTOR. <br />C. APPROXIMATE LOCATIONS OF EXISTING UTILITIES HAVE BEEN OBTAINED FROM <br />AVAILABLE RECORDS AND ARE SHOWN FOR CONVENIENCE. THE CONTRACTOR SHALL <br />BE RESPONSIBLE FOR VERIFICATION OF LOCATIONS AND TO AVOID DAMAGE TO ANY <br />ADDITIONAL UTILITIES NOT SHOWN. IF CONFLICTS WITH EXISTING UTILITIES ARISE <br />DURING CONSTRUCTION, THE CONTRACTOR SHALL NOTIFY THE PUBLIC WORKS <br />INSPECTOR AND ANY CHANGES REQUIRED SHALL BE APPROVED BY THE CITY <br />ENGINEER PRIOR TO COMMENCEMENT OF RELATED CONSTRUCTION ON THE PROJECT. <br />D. ALL SEWER MAIN EXTENSIONS WITHIN THE PUBLIC RIGHT-OF-WAY OR IN EASEMENTS <br />MUST BE STAKED BY SURVEY FOR LINE AND GRADE PRIOR TO STARTING <br />CONSTRUCTION. <br />NOTE: <br />THE CURRENT DESIGN AND CONSTRUCTION STANDARDS AND SPECIFICATIONS ARE <br />AVAILABLE ONLINE AT HTTPS://EVERETTWA.GOV/1531/DESIGN-CONSTRUCTION-STANDARDS <br />SEWER MAIN SYSTEM GENRAL NOTES: <br />CONSTRUCTION OF ALL SANITARY SEWER MAINS, SIDE <br />SEWERS (LATERALS) - WHETHER SIDE SEWERS ARE BY GRAVITY, BY FORCE <br />MAIN, OR PRESSURE SEWER -AND RELATED FACILITIES, INCLUDING BUT <br />NOT LIMITED TO SEWER LIFT STATIONS, TELEMETRY FACILITIES AND <br />APPURTENANCES WILL BE UNDER THE SUPERVISION OF THE CITY AND <br />SHALL BE IN COMPLIANCE WITH ALL ORDINANCES AND CURRENT <br />STANDARDS OF THE CITY OF EVERETT, WASHINGTON STATE DEPARTMENT <br />OF ECOLOGY CRITERIA FOR SEWAGE WORKS DESIGN (ORANGE BOOK), OR <br />THE UNIFIED PLUMBING CODE AS APPLICABLE. <br />SEWER MAIN EXTENSIONS WILL BE REQUIRED WHEN THE PROPERTY DOES <br />NOT FRONT ON A SEWER MAIN OR WHEN THE EXISTING SEWER MAIN IS <br />NOT ADEQUATE FOR THE INCREASED USE PROPOSED. THE MINIMUM <br />EXTENSION SHALL BE TO A POINT AT LEAST 5 FEET INSIDE THE <br />PROLONGATION OF THE PROPERTY LINE. <br />EACH SIDE SEWER SHALL SERVE ONLY ONE BUILDING AND ONE PARCEL <br />(ONE CONNECTION FROM LOT TO MAIN) PER SECTION 6-8.3 AND EMC <br />14.08.170. <br />ALL NEW SEWER CONNECTIONS SHALL COMPLY WITH BACKWATER VALVE <br />REQUIREMENTS IN EMC 14.08.180 B. 1. <br />ALL PIPE INSTALLED SHALL BE STRUCTURALLY SOUND FOR THE DESIGN <br />DEPTH. <br />REQUIREMENTS FOR NEW PROPOSED LIFT (PUMP) STATIONS TO BE <br />DEDICATED TO THE CITY ARE PROVIDED IN SECTION 6-5.1 AND PER THE <br />CITY'S CURRENT LIFT STATION STANDARDS AS ESTABLISHED BY THE CITY'S <br />MAINTENANCE DIVISION/SEWER UTILITY. LIFT STATIONS ARE DEFINED AS <br />SEWAGE PUMPING SYSTEMS THAT SERVE MULTIPLE RESIDENTIAL LOTS OR <br />A NON-RESIDENTIAL DEVELOPMENT GENERATING SIGNIFICANT SEWAGE <br />VOLUME. LIFT STATIONS MUST BE DEMONSTRATED TO BE NEEDED, COST <br />EFFECTIVE FOR THE CITY TO OWN AND MAINTAIN BASED ON SEWER RATES <br />AND LIFECYCLE 0&M COSTS, MEET THE MAINTENANCE DIVISION <br />STANDARDS, AND BE PERMITTED AND APPROVED SOLELY AT THE INTEREST <br />OF THE DEPARTMENT. GRINDER PUMP INSTALLATION FOR INDIVIDUAL <br />PARCELS MAY BE ALLOWED UNDER SEPARATE REVIEW PER SECTION 6-5.2. <br />ALL REQUESTS FOR INSPECTIONS AND FOR WITNESSING ACCEPTANCE <br />TESTS SHALL BE SCHEDULED WITH THE PUBLIC WORKS INSPECTOR AT <br />LEAST 24 HOURS IN ADVANCE. FAILURE TO GIVE ADEQUATE ADVANCE <br />NOTICE MAY RESULT IN DELAYS TO THE CONTRACTOR FOR REQUIRED <br />INSPECTIONS. <br />