Laserfiche WebLink
SS MH, TYPE 3, 48" 0 <br />CDC4:)PER COE STD DWG 607 EXCEPT AS NOTED <br />RIM=17.1' 16.90' <br />IE=15.0' 14.70' (3" VENT) <br />IE=H 4.9' 14.56' (3" SSFM OUTLET) <br />IE=13.50' (6" SS INLET E) <br />IE=13.50' (6" SS INLET N) <br />O 3" HDPE VENT PIPE, <br />I E=16.0' 14.70' <br />FLOAT SWITCH, TYP <br />NON -SHRINK GROUT, TYP <br />6" SS, SEE <br />SHT C5.9 - <br />REFER TO GEOTECHNICAL REPORT <br />FOR GROUNDWATER DATA <br />JIM 12" <br />�7 <br />STRUCTURE SUBGRADE PREPARATION, <br />SEE DETAIL 2 ON C4.17 <br />Port of <br />EVERETT <br />P,0 BOX 538 <br />EVERETT, WA 98206 <br />(425) 259-3164 <br />•'v <br />Fj <br />LADDER OR RUNGS, TYP <br />(2) CONDUITS PER ELEC <br />FOR POWER AND CONTROLS <br />SEAL MH PENETRATION TO <br />BE WATER -TIGHT. <br />LINK SEAL OR EQUAL, TYP <br />v <br />3" SSFM IE=1 A Q <br />O14.56' <br />V-7 L <br />I I <br />IL -ALARM ON ELEV=14.5' <br />PUMP ON ELEV=14.0' <br />- *: .4 <br />J • <br />1 1 CO <br />PUMP OFF ELEV=12.9' <br />D D v BOT OF WET WELL=11.6' <br />ILJv p p u <br />SANITARY SEWER SIMPLEX LIFT STATION DETAIL <br />FOR LONGSHOREMAN TRAILERS <br />22 SCALE: NTS <br />1601 5th Avenue, Suite 1300 <br />Seattle, Washington 98101 <br />(206) 382-0600 Fax (206) 382-0500 <br />PROJECT NO. 1600120 <br />07/05/2023 NW <br />12/02/2021 NW <br />0 05/21/2021 NW <br />/D 05/07/2021 NW <br />N0, I DATE I BY <br />RECORD DRAWING <br />2—INCH TO 9—INCH PVMT <br />ISSUED FOR BID <br />FOR CITY REVIEW <br />REVISION <br />N0, I DATE I BY <br />REVISION <br />RIM=16.90' <br />IECORD CONDITIONS <br />ILLUSTRATED IN THESE <br />'LANS REFLECT <br />INFORMATION <br />'ROVIDED BY THE <br />:ONTRACTOR.RECORD <br />:ONDITIONS WERE NOl <br />✓ERIFIED BY ENGINEER. <br />0 <br />NOTES <br />O ROUTE VENT PIPE TO PORTABLE TRAILER AND CONNECT TO TRAILER VENT SYSTEM OR RUN <br />NEW VENT PIPE UP SIDE OF TRAILER AND TERMINATE 6" MINIMUM ABOVE ROOF LINE IN <br />CONFORMANCE WITH CURRENT PLUMBING CODE. SLOPE AT 1% MINIMUM UPHILL TO TRAILER <br />CONNECTION TO PROVIDE POSITIVE AIR FLOW TO VENT. <br />O CONTRACTOR SHALL FURNISH AND INSTALL THE PUMP SYSTEM INCLUDING RAILS, FLOAT <br />SWITCHES AND CONTROL PANEL IN CONFORMANCE WITH THE MANUFACTURERS <br />RECOMMENDATIONS. <br />O SECURE FORCEMAIN PIPE TO MH WITH 316 SS PIPE STRAPS. SECURE PIPE STRAPS TO <br />MANHOLE WALL WITH 5/8"0 316 SS EXPANSION BOLTS OR EMBED STRAPS INTO MH WALL <br />2" WITH GROUT. <br />® UTILITY STRUCTURE AND LID SHALL BE CONTRACTOR DESIGNED IN CONFORMANCE WITH THE <br />UNDERGROUND UTILITY STRUCTURES DESIGN LOADING CRITERIA NOTES AND THE TAYLOR <br />"BIG RED" THDC-976 CONTAINER HANDLER INFORMATION ON SHEEP G1.3. <br />EQUIPMENT LIST <br />0 <br />3" PVCxHDPE TRANSITION FITTING <br />O <br />NOT USED <br />O3 <br />3" PVC UNION <br />O4 <br />3"xO.075", 316 SS FLAT BAR PIPE STRAP <br />SEE NOTE O <br />O5 <br />3" PVC CHECK VALVE WITH DIAPHRAM <br />O6 <br />3"X90 SCH 80 PVC, EL, TYP <br />O <br />PUMP RAIL SYSTEM MODEL NO. GR20 OR EQUAL AS RECOMMENDED BY <br />PUMP MANUFACTURER <br />O8 <br />3" SCH 80 PVC SSFM <br />SEE NOTECD <br />LIBERTY PUMP SUBMERSIBLE, EXPLOSION PROOF, SEWAGE GRINDER <br />PUMP MODEL NO. XLSG202M OR APPROVED EQUAL <br />O9 <br />MOTOR 2HP, VOLTAGE 230, PHASE 1 <br />OPERATING POINT APPROX 46 GPM AT 56' OF TOTAL DYNAMIC HEAD <br />CAP KIT: K001641 AND SIMPLEX PANEL: ISS24HS1 =3-5. <br />10 <br />QUICK DISCONNECT ADAPTOR <br />1 1 <br />1-1 /4" TO 3" REDUCER, SCH 80 PVC <br />12 <br />2'x3' HINGED DUCTILE IRON ACCESS HATCH, AS MANUFACTURED BY <br />SEE NOTE <br />NEENAH FOUNDRY, MODEL NO. R-3498-J3S OR EQUAL <br />PROJECT ENGINEER: <br />N. WATSON <br />DESIGNED BY: <br />J. BECKER <br />DRAWN BY: <br />K. EDWARDS, D. YU <br />APPROVED BY <br />SCALE: <br />AS SHOWN <br />DATE: <br />05/07/2021 <br />CHECKED BY: <br />N. WATSON <br />RECORD DRAWING <br />PORT OF EVERETT <br />NORTON TERMINAL DEVELOPMENT <br />& MTCA 3RD INTERIM ACTION <br />SEWER DETAILS <br />(2 OF 2) <br />IF SHEET IS LESS THAN 22x34 <br />REDUCE SCALE ACCORDINGLY <br />DWG. NO. C5.22 <br />CIP NO. <br />1-8-900-05 <br />PROJECT <br />NO MT-NT-2021 -02.2 <br />SHEET NO. 79 OF 150 <br />Z <br />a <br />U <br />LU <br />